AirWorks AWK-3131A Web Console Configuration
To download the configuration to the AWK:
1. Turn off the AWK.
2. Plug in the ABC-01 to the AWK’s RS-232 console.
3. Turn on AWK.
4. AWK will detect ABC-01 during bootup, and download the configuration from the ABC-01 to the AWK
automatically. Once the configuration downloads and if configuration format is correct, the AWK will emit
three short beeps, then continue the boot up.
5. Once the AWK has booted up successfully, it will emit the normal two beeps, and the ready LED will turn
to solid green.
Load Factory Default
Use this function to reset the AWK-3131A and roll all settings back to the factory default values. You can
also reset the hardware by pressing the reset button on the top panel of the AWK-3131A.
Password
You can change the administration password for each of the AWK-3131A’s console managers by using the
Password function. Before you set up a new password, you must input the current password and reenter
the new password for confirmation. For your security, do not use the default password root, and remember
to change the administration password regularly.
Misc. Settings
Additional settings to help you manage your AWK-3131A, are available on this page.
Reset button
Setting Description Factory Default
Always enable The AWK-3131A’s Reset button works normally. Always enable
Disable after 60 sec The AWK-3131A’s reset to default function will be inactive 60
seconds after the AWK-3131A finishes booting up.
3-40