NE-4100 Series User’s Manual Initial IP Address Configuration
5-3
arp –s 192.168.200.100 00-90-E8-xx-xx-xx
This is where 192.168.200.100 is the new IP address and 00-90-E8-xx-xx-xx is the MAC address
for your WE-2100T. You will need to use both numbers, as described above in points 1 and 2.
4. Next, execute a special Telnet command by typing:
telnet 192.168.200.100 6000
After issuing this command, a Connect failed message will
appear, as shown here. After the WE-2100T module reboots,
its IP address should be updated to the new address, and you
can reconnect using Telnet, Web, or Administrator to check
that the update was successful.
Telnet Console
Depending on how your computer and network are configured, you may find it convenient to use
network access to set up your WE-2100T module’s IP address. This can be done using the Telnet
program.
1. From the Windows desktop, click on Start and then select Run.
2. Type telnet 192.168.126.254 (use the
correct IP address if different from the default) in
the Open text input box, and then click OK.
3. Type Enter to select
terminal type.
4. Press N to select Network
and then press Enter.