User's Manual

Table Of Contents
NE-4100 Series User’s Manual Web Console Configuration
6-15
Up to 4 connections can be established between WE-2100T and hosts. The connection speed or
throughput may be low if one of the four connections is slow. In this case, the other 3 connections will
be delayed while waiting for the slowest connection to finish transmitting or receiving.
The “Destination IP address” parameter can use both IP address and Domain address. For some
applications, the user may need to send the data actively to the remote destination domain address.
TCP connection on
Setting Factory Default Necessity
Start up,
Any Character
Start up Optional
Start up: Attempts to establish a TCP connection as soon as the WE-2100T is powered on.
Any Character: Attempts to establish a TCP connection as soon as the WE-2100T starts receiving
serial data.
UDP Mode
Delimiter 1
Setting Factory Default Necessity
00 to FF “0” for None Optional
Delimiter 2
Setting Factory Default Necessity
00 to FF “0” for None Optional
Once the WE-2100T receives both delimiters through the serial port, it immediately packs all data
currently in its buffer and sends it to the WE-2100T’s Ethernet port.
Note: Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer.