NE-4100 Series User’s Manual Web Console Configuration
6-19
Event Type
Cold start
This refers to starting the system from power off (contrast this with warm start). When performing
a cold start, WE-2100T will automatically issue an Auto warning message by e-mail, or send an
SNMP trap after rebooting.
Warm start
This refers to restarting the computer without turning the power off. It’s the opposite of cold start.
When performing a warm start, WE-2100T will automatically send an e-mail, or send an SNMP
trap after rebooting.
Authentication failure
The user inputs a wrong password from the Console or Administrator. When authentication
failure occurs, WE-2100T will immediately send an e-mail or send an SNMP trap.
IP address changed
The user has changed WE-2100T’s IP address. When the IP address changes, WE-2100T will
send an e-mail with the new IP address before WE-2100T reboots. If the WE-2100T fails to send
mail to the mail server after 15 seconds, WE-2100T will reboot directly and abort the mail auto
warning.
Password changed
The user has changed WE-2100T’s password. When the password changes, WE-2100T will send
an e-mail with the password change notice before WE-2100T reboots. If the WE-2100T fails to
send mail to the mail server after 15 seconds, WE-2100T will reboot directly and abort the mail
auto warning.
DCD changed
The DCD (Data Carrier Detect) signal has changed, also indicating that the modem connection
status has changed. For example, a DCD change to high also means “Connected” between local
modem and remote modem. If the DCD signal changes to low, it also means that the connection
line is down.
When the DCD changes, WE-2100T will immediately send an e-mail or send an SNMP trap.
DSR changed
The DSR (Data Set Ready) signal has changed, also indicating that the data communication
equipment’s power is off. For example, a DSR change to high also means that the DCE is
powered ON. If the DSR signal changes to low, it also means that the DCE is powered off.
When the DSR changes, WE-2100T will immediately send an e-mail or send an SNMP trap.
Mail
Setting Factory Default Necessity
Enable, Disable Disable Optional
This feature helps the administrator manage the WE-2100T. WE-2100T sends mail to pre-defined