Instructions / Assembly
Troubleshooting/Cautions
• Door is too tight or binds: Check that the frame is square and plumb and not twisted.
Ensure that the sill is not bowed and is level.
• Daylight showing between frame and door: Check weatherstrip margins and compression.
Ensure dust pad is afxed to the lower portion of the jamb leg. Make sure the door sweep
is attached properly.
• In order for the door unit to perform properly, it is CRITICAL that the hinge and strike
jambs are parallel to each other.
• Do not use the wall to square, level and plumb the unit. Opening walls are rarely
square, level and plumb.
• Units must be square, level and plumb to ensure proper operation and performance.
• Follow the same method for the second strike.
• Adjust strike in or out for proper door operation and tighten screws.
• It is recommended one additional screw is placed behind the weatherstrip at the top of
the hinge jamb.
• Check dust pad position to ensure no movement during transportation. Dust pads should
be ½” from the top of the composite portion of the sill to the bottom of the dust pad.
MP Doors Customer Service: 1-888-366-7717