User`s guide
▼
To Congure Individual DevicesWith Sun StorageTek
Trac Manager Software
This sample procedure uses fabric-connected host ports c0 and c2 to congure fabric devices as
multipath devices on a host that has the Sun StorageTek Trac Manager software enabled.
The cfgadm -c configure command for fabric devices is the same regardless of whether
multipathing is enabled.
Loginasroot(su - root)..
Identify the port WWN of the device to be congured as the Sun StorageTek Trac Manager
software device.
Look for devices on a fabric-connected host port marked as fc-fabric. These devices are the
devices you can congure with the cfgadm -c configure command.
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 fc-fabric connected unconfigured unknown
c0::50020f2300006077 disk connected unconfigured unknown
c0::50020f23000063a9 disk connected unconfigured unknown
c1 fc-private connected configured unknown
c1::220203708b69c32b disk connected configured unknown
c1::220203708ba7d832 disk connected configured unknown
c1::220203708b8d45f2 disk connected configured unknown
c1::220203708b9b20b2 disk connected configured unknown
c2 fc-fabric connected unconfigured unknown
c2::50020f2300005f24 disk connected unconfigured unknown
c2::50020f2300006107 disk connected unconfigured unknown
In the above example, the c0::50020f2300006077 and c2::50020f2300006107 Ap_Ids
represent the same storage device with dierent port WWNs for the storage device controllers.
The c0 and c2 host ports are enabled for use by the Sun StorageTek Trac Manager software.
Congure the fabric device and make the devices available to the host.
# cfgadm -c configure c0::50020f2300006077 c2::50020f2300006107
Verify that the selected devices are congured.
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 fc-fabric connected configured unknown
c0::50020f2300006077 disk connected configured unknown
c0::50020f23000063a9 disk connected unconfigured unknown
c1 fc-private connected configured unknown
c1::220203708b69c32b disk connected configured unknown
c1::220203708ba7d832 disk connected configured unknown
1
2
3
4
Conguring Device Nodes With Solaris Multipathing Software Enabled
Solaris SAN Conguration and Multipathing Guide • April 200986