User`s guide

To Congure Individual DevicesWith Sun StorageTek
Trac Manager Software
This sample procedure uses fabric-connected host ports c0 and c2 to congure fabric devices as
multipath devices on a host that has the Sun StorageTek Trac Manager software enabled.
The cfgadm -c configure command for fabric devices is the same regardless of whether
multipathing is enabled.
Loginasroot(su - root)..
Identify the port WWN of the device to be congured as the Sun StorageTek Trac Manager
software device.
Look for devices on a fabric-connected host port marked as fc-fabric. These devices are the
devices you can congure with the cfgadm -c configure command.
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 fc-fabric connected unconfigured unknown
c0::50020f2300006077 disk connected unconfigured unknown
c0::50020f23000063a9 disk connected unconfigured unknown
c1 fc-private connected configured unknown
c1::220203708b69c32b disk connected configured unknown
c1::220203708ba7d832 disk connected configured unknown
c1::220203708b8d45f2 disk connected configured unknown
c1::220203708b9b20b2 disk connected configured unknown
c2 fc-fabric connected unconfigured unknown
c2::50020f2300005f24 disk connected unconfigured unknown
c2::50020f2300006107 disk connected unconfigured unknown
In the above example, the c0::50020f2300006077 and c2::50020f2300006107 Ap_Ids
represent the same storage device with dierent port WWNs for the storage device controllers.
The c0 and c2 host ports are enabled for use by the Sun StorageTek Trac Manager software.
Congure the fabric device and make the devices available to the host.
# cfgadm -c configure c0::50020f2300006077 c2::50020f2300006107
Verify that the selected devices are congured.
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 fc-fabric connected configured unknown
c0::50020f2300006077 disk connected configured unknown
c0::50020f23000063a9 disk connected unconfigured unknown
c1 fc-private connected configured unknown
c1::220203708b69c32b disk connected configured unknown
c1::220203708ba7d832 disk connected configured unknown
1
2
3
4
Conguring Device Nodes With Solaris Multipathing Software Enabled