User`s guide

Verify that the selected devices are uncongured.
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 fc-fabric connected configured unknown
c0::50020f2300006077 disk connected unconfigured unknown
c0::50020f23000063a9 disk connected configured unknown
c1 fc-private connected configured unknown
c1::220203708b69c32b disk connected configured unknown
c1::220203708ba7d832 disk connected configured unknown
c2 fc-fabric connected configured unknown
c2::50020f2300005f24 disk connected configured unknown
c2::50020f2300006107 disk connected unconfigured unknown
Notice that the Ap_Ids c0::50020f2300006077 and c2::50020f2300006107 are uncongured.
The Occupant column of c0 and c2 still displays those ports as configured because they have
other congured occupants.
The Sun StorageTek Trac Manager software devices associated with the Ap_Ids
c0::50020f2300006077 and c2::50020f2300006107 are no longer available to the host using
the Solaris 10 OS. The following two devices are removed from the host:
/dev/rdsk/c6t60020F20000061073AC8B52D000B74A3d0s2
/dev/rdsk/c6t60020F20000061073AC8B4C50004ED3Ad0s2
To Uncongure One Path to a Multipathing Device
In contrast to the procedure in the preceding section, this procedure shows how to uncongure
one device associated with c2::50020f2300006107 and leave the other device,
50020f2300006077, congured. Only devices on a fabric-connected host port can be
uncongured through the cfgadm unconfigure command.
Loginasroot(su - root)..
Identify the Ap_Id of the Sun StorageTek Trac Manager software device to be uncongured.
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 fc-fabric connected configured unknown
c0::50020f2300006077 disk connected configured unknown
c0::50020f23000063a9 disk connected configured unknown
c1 fc-private connected configured unknown
c1::220203708b69c32b disk connected configured unknown
c1::220203708ba7d832 disk connected configured unknown
c2 fc-fabric connected configured unknown
c2::50020f2300005f24 disk connected configured unknown
c2::50020f2300006107 disk connected configured unknown
In this example, c0::50020f2300006077 and c2::50020f2300006107 Ap_Ids represent
dierent port WWNs for the same device.
5
1
2
Unconguring Fabric Devices
Solaris SAN Conguration and Multipathing Guide • April 200992