User`s guide
Verify that the selected devices are uncongured.
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 fc-fabric connected configured unknown
c0::50020f2300006077 disk connected unconfigured unknown
c0::50020f23000063a9 disk connected configured unknown
c1 fc-private connected configured unknown
c1::220203708b69c32b disk connected configured unknown
c1::220203708ba7d832 disk connected configured unknown
c2 fc-fabric connected configured unknown
c2::50020f2300005f24 disk connected configured unknown
c2::50020f2300006107 disk connected unconfigured unknown
Notice that the Ap_Ids c0::50020f2300006077 and c2::50020f2300006107 are uncongured.
The Occupant column of c0 and c2 still displays those ports as configured because they have
other congured occupants.
The Sun StorageTek Trac Manager software devices associated with the Ap_Ids
c0::50020f2300006077 and c2::50020f2300006107 are no longer available to the host using
the Solaris 10 OS. The following two devices are removed from the host:
/dev/rdsk/c6t60020F20000061073AC8B52D000B74A3d0s2
/dev/rdsk/c6t60020F20000061073AC8B4C50004ED3Ad0s2
▼
To Uncongure One Path to a Multipathing Device
In contrast to the procedure in the preceding section, this procedure shows how to uncongure
one device associated with c2::50020f2300006107 and leave the other device,
50020f2300006077, congured. Only devices on a fabric-connected host port can be
uncongured through the cfgadm unconfigure command.
Loginasroot(su - root)..
Identify the Ap_Id of the Sun StorageTek Trac Manager software device to be uncongured.
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 fc-fabric connected configured unknown
c0::50020f2300006077 disk connected configured unknown
c0::50020f23000063a9 disk connected configured unknown
c1 fc-private connected configured unknown
c1::220203708b69c32b disk connected configured unknown
c1::220203708ba7d832 disk connected configured unknown
c2 fc-fabric connected configured unknown
c2::50020f2300005f24 disk connected configured unknown
c2::50020f2300006107 disk connected configured unknown
In this example, c0::50020f2300006077 and c2::50020f2300006107 Ap_Ids represent
dierent port WWNs for the same device.
5
1
2
Unconguring Fabric Devices
Solaris SAN Conguration and Multipathing Guide • April 200992