mLink MP290 Portable Wireless Gateway User Manual V1.
MP290 Portable Wireless Gateway 目录 1. Product Overview ..............................................................................................................................3 2. Operation .............................................................................................................................................4 2.1. Power On ......................................................................................................................................................4 2.2.
MP290 Portable Wireless Gateway Read Before Operating This manual must be carefully read by all individuals who have or will have the responsibility of using, maintaining or servicing this product. The product will perform as designed only if it is used, maintained and serviced in accordance with the manufacturer’s instructions. The user should understand how to set the correct parameters and interpret the obtained results. WARNINGS ! This device complies with part 15 of the FCC Rules.
MP290 Portable Wireless Gateway 1. Product Overview MP290 is a gateway platform for on-site real-time forwarding or uploading of terminal device data. It communicates with terminal devices such as VOXI (Mounti), NEO, etc. using shortrange wireless module MP280L. After the gateway collects terminal device data, it can upload the information to the cloud server through the internal BLE module. If there is no available network connection on site, this device can also relay data with another host within 2~3Km.
MP290 Portable Wireless Gateway is low. After releasing the button, the mLink will automatically shut down. Please charge the mLink. 2.2. Power Off In power-on state, press the button for 5 seconds, the red LED will be on. After the button is released, the mLink will automatically shut down. It should be noted that the mLink will automatically shut down when the battery is too low. 2.3.
MP290 Portable Wireless Gateway 3.2. Operating Environment 3.2.1. Hardware Requirement Devices such as Android phones and Android tablets. 3.2.2. System Requirement Android(6.0 and above) 3.2.3. Operating Environment Requirement Safety area, non-hazardous. 3.3. Operation 3.3.1. Search and connect detectors 1、Run App,click button,as shown in Figure 1. 图 1 搜寻仪器 6 (C) mPower Electronics (Shanghai) Co., Ltd. Rev.
MP290 Portable Wireless Gateway 2、Click to select detector, as shown in figure2. 图 2 连接仪器 3、Repeat steps 1 and 2, to connect other detectors. As shown in figure 3. Up to 8 detectors can be connected at the same time. 图 3 连接多个仪器 7 (C) mPower Electronics (Shanghai) Co., Ltd. Rev.
MP290 Portable Wireless Gateway 3.3.2. Disconnect the detectors Click the button below the detector icon to disconnect 3.3.3. Shortcut buttons The short buttons are: 1) Disconnect 2) Bluetooth connection (status) If the Bluetooth connection of the mLink is lost, the panel of the mLink is grayed out. Clicking on the Bluetooth connection (status) will try to reconnect.
MP290 Portable Wireless Gateway 3.3.4.1. System Click "Register Device" to start the operation of wireless device registration to the gateway. 9 (C) mPower Electronics (Shanghai) Co., Ltd. Rev.
MP290 Portable Wireless Gateway After the device is registered, it will be shown in the list. Up to 50 devices can be registered (but 8 devices are connected at the same time). Click "Remove" to unregister the device; Click "Test" to check the device. After receiving the command, the buzzer of the device will sound and flash the light. After entering the device holder number on the lower right side, click "Distribute to" to send the user ID to the device.
MP290 Portable Wireless Gateway After the device is registered, the wireless gateway starts to monitor the detectors. 3.3.4.2 Team Click "Team" to start real-time monitoring At the top of the screen is the status of the gateway, including the battery, Bluetooth and the last update time (updated every second). Below is a list of online detectors. Detector information includes wireless signal, battery, status and update time, and alarm duration (if there is an alarm).
MP290 Portable Wireless Gateway note: 1) Only one detector can be selected in the system at the same time. 2) When the detector is not selected, the system reads the detector information every 60 seconds; if the detector is selected, the system reads the detector information every 15 seconds. 3) After entering the gateway operation (real-time monitoring), the app starts the sound and vibration alarm, you can temporarily turn off the sound alarm in the app settings.
MP290 Portable Wireless Gateway 3.3.4.3 Event Log Click "Event" and select a date from the date list at the bottom of the screen to view daily event records. 13 (C) mPower Electronics (Shanghai) Co., Ltd. Rev.
MP290 Portable Wireless Gateway 3.4. Software Information Click the button on the main screen to show software information. Including "EULA" (End User License Agreement), "Software Settings", "Data Recording", "Event Recording" and "Software Log". 3.4.1. EULA Click "EULA" to view App License related content. Note: If you do not agree to any terms of the EULA, the user should delete the software immediately. 14 (C) mPower Electronics (Shanghai) Co., Ltd. Rev.
MP290 Portable Wireless Gateway 3.4.2. Software Setting Click "Software Settings" to set up the app.
MP290 Portable Wireless Gateway 3.4.3. Data Logging Click "Data Record" and select the instrument/user from the instrument/user list at the bottom of the screen to view the data record. At the same time, you can send data records by email (in txt text), and hide the record (retrieved by "show all records" in the software settings).
MP290 Portable Wireless Gateway 17 (C) mPower Electronics (Shanghai) Co., Ltd. Rev.
MP290 Portable Wireless Gateway 3.4.4. Event Log Click "Event" and select a date from the date list at the bottom of the screen to view daily event records. 18 (C) mPower Electronics (Shanghai) Co., Ltd. Rev.
MP290 Portable Wireless Gateway 3.4.5. Software Log Click "Software Log" and select the date from the date list at the bottom of the screen to view the daily log. This log is mainly used for general app operation error checking. 19 (C) mPower Electronics (Shanghai) Co., Ltd. Rev.