PARTS AND OPERATION MANUAL OPERATION AND PARTS MANUAL WHISPERWATTTM SERIES MODEL DCA-36SPX 60 Hz GENERATOR (PARTS LIST NO. B2871300404 S/N 3798495~) Revision #1 (04/14/10) THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
PROPOSITION 65 WARNING Diesel engine exhaust and some of PAGE 2 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
NOTE PAGE 1 DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
TABLE OF CONTENTS MQ POWER DCA-36SPX WHISPER WATTTM GENERATOR WHISPERW California Proposition 65 Warning ..................................... 2 Here's How To Get Help .................................................... 3 Table Of Contents ............................................................. 4 Parts Ordering Procedures ............................................... 5 Specifications ................................................................... 6 Dimensions (Top, Side, Front) ................
www.mqpower.com PARTS ORDERING PROCEDURES Ordering parts has never been easier! Choose from three easy options: Order via Internet (Dealers Only): Best Deal! Effective: January 1st, 2006 If you have an MQ Account, to obtain a Username and Password, E-mail us at: parts@multiquip. com. Order parts on-line using Multiquip’s SmartEquip website! N View Parts Diagrams N Order Parts N Print Specification Information To obtain an MQ Account, contact your District Sales Manager for more information.
DCA-36SPX — SPECIFICATIONS Table 1. Generator Specifications Model DCA-36SPX Type Revolving field, self-ventilated drip-proof, single bearing Armature Connection Series Phase Single Phase 3-Wire Standby Output 37.8 KW Prime Output 36 KW Voltage 2 4 0 V /1 2 0 Frequency 60 Hz Speed 1800 r pm Power Factor 1.0 Aux. AC Power Single Phase, 60 Hz Voltage 120 V Output 4.8 KW (2.4 KW x 2) Table 2.
DCA-36SPX — DIMENSIONS (TOP, SIDE AND FRONT) B C D TOP VIEW E A Figure 1. Dimensions 36 SIDE VIEW F FRONT VIEW TABLE 3. DIMENSIONS Denyo G Reference Letter Dimension ft. (mm.) Reference Letter Dimension ft. (mm.) A 29.1 in. (738 mm.) F 74.8 in. (1,900 mm.) B 29.1 in. (738 mm.) G 49.21 in. (1,250 mm.) C 24.2 in. (615 mm.) H 35.43 in. (900 mm.) D 30.3 in. (770 mm.) E 25.0 in. (635 mm.) H DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX — SAFETY MESSAGE ALERT SYMBOLS FOR YOUR SAFETY AND THE SAFETY OF OTHERS! Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the Safety Messages and Operating Instructions could result in injury to yourself and others. NOTE This Owner's Manual has been developed to provide complete instructions for the safe and efficient operation of the MQ Power Model DCA-36SPX Whisperwatt™ Generator.
DCA-36SPX — SAFETY MESSAGE ALERT SYMBOLS WARNING - ROTATING PARTS NEVER operate equipment with covers, or guards removed. Keep fingers, hands, hair and clothing away from all moving parts to prevent injury. CAUTION - ACCIDENTAL STARTING ALWAYS place the engine ON/OFF switch (MPEC) in the OFF/RESET position when the generator is not in use. CAUTION - OVER-SPEED CONDITIONS NEVER tamper with the factory settings of the engine governor or settings.
DCA-36SPX — RULES FOR SAFE OPERATION DANGER - READ THIS MANUAL! Failure to follow instructions in this manual may lead to serious injury or even DEATH! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only. The following safety guidelines should always be used when operating the DCA-36SPX Whisperwatt™ AC Generator. ■ NEVER use accessories or attachments, which are not recommended by Multiquip for this equipment.
DCA-36SPX — RULES FOR SAFE OPERATION ■ ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using generators. NEVER leave the generator unattended, turn off engine when unattended. Unauthorized equipment modifications will void all warranties. ALWAYS ensure generator is on level ground before use. DO NOT place hands or fingers inside generators engine compartment when engine is running. NEVER run engine without air cleaner. Severe engine damage may occur.
DCA-36SPX — RULES FOR SAFE OPERATION WARNING - BURN HAZARDS Battery Safety Use the following guidelines when handling the battery: To prevent burns, DO NOT touch or open any of the below mentioned components while the engine is running or immediately after operations. Always allow sufficient time for the engine and generator to cool before performing maintenance.
DCA-36SPX — RULES FOR SAFE OPERATION Generator exhaust contains carbon monoxide. This is a posion you cannot see or smell 20A 2900 120 V OFF GA-2.9R 120V 20A 2900 120V ON OFF AC CIRCUIT BREAKER 20A 2900 120 V GA-2.9R 22A NEVER grab or touch a live power cord with wet hands, the possibility exist of electrical shock, electrocution, and even death! DANGER Using a generator indoors CAN KILL YOU IN MINUTES. 120 V ON GA-2.
DCA-36SPX — RULES FOR SAFE OPERATION If your generator is trailer mounted, please read the towing and safety requirements listed below. Towing and Transporting Safety To reduce the possibility of an accident while transporting the generator on public roads, always make sure the trailer that supports the generator and the towing vehicle are in good operating condition and both units are mechanically sound.
NOTE PAGE 1 DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX — GENERATOR DECALS The DCA-36SPX generator is equipped with a number of safety decals (Figures 2 and 3). These decals are provided for operator safety and maintenance information. The illustration below and on the preceding page show the decals as they appear on the machine. Should any of these decals become unreadable, replacements can be obtained from your dealer. Figure 2. Generator Decals PAGE 16 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX — GENERATOR DECALS Figure 3. Generator Decals (Cont inued) DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX — INSTALLATION Figure 4. Typical Generator Grounding Application PAGE 18 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX — INSTALLATION Outdoor Installation Generator Grounding Install the generator in a area that is free of debris, bystanders, and overhead obstructions. Make sure the generator is on secure level ground so that it cannot slide or shift around. Also install the generator in a manner so that the exhaust will not be discharged in the direction of nearby homes. The installation site must be relatively free from moisture and dust. All electrical equipment should be protected from excessive moisture.
DCA-36SPX — GENERAL INFORMATION DCA-36SPX Whisperwatt™ Series Familiarization Generator The MQ Power Model DCA-36SPX is a 36 kW generator (Figure 5) that is designed as a high quality portable (requires a trailer for transport) power source for telecom sites, lighting facilities, power tools, submersible pumps and other industrial and construction machinery.
DCA-36SPX — MAJOR COMPONENTS 1 36 U O V 2 3 4 36 U 8 7 O V 5 6 9 Table 4. Generator Major Components ITEM NO. AUTO DESCRIPTION MANUAL OFF/RESET LOW OIL PRESSURE HIGH COOLANT TEMPERATURE OVERCRANK OVERSPEED ENGINE RUNNING MOOOOO-20001Q 11 10 Figure 5.
NOTE PAGE PAGE 22 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX — GENERATOR CONTROL PANEL 4 DECREASE INCREASE HZ 1 A 2 V 3 V 5 U W OFF 6 Figure 6. Generator Control Panel The definitions below describe the controls and functions of Located behind the generator control panel is the Generator Control Box. This box contains some of the necessary the DCA-36SPX Generator Control Panel (Figure 6). 1. Frequency Meter – Indicates the output frequency in electronic components required to make the generator function. hertz (Hz). Normally 60 Hz. 2. 3. 4. 5.
DCA-36SPX — ENGINE OPERATING PANEL Figure 7. Engine Operating Panel PAGE 24 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX — ENGINE OPERATING PANEL The definitions below describe the controls and functions of the DCA-36SPX Engine Operating Panel (Figure 7). 1. Panel Light – Normally used in dark areas or at night time. When activated, panel lights will illuminate. When the generator is not in use be sure to turn the panel light switch to the OFF position. 2. Panel Light Switch – When activated will turn on control panel light. 3.
DCA-36SPX — OUTPUT TERMINAL PANEL FAMILIARIZATION Output Terminal Panel The Output Terminal Panel (Figure 8) shown below is located on the right-hand side (left from control panel) of the generator. Lift up on the cover to gain access to receptacles and terminal lugs.
DCA-36SPX — OUTPUT TERMINAL PANEL FAMILIARIZATION 100 VAC GFCI Receptacles There are two 120 VAC, 20 amp GFCI (Duplex Nema 5-20R) recepacles provided on the output terminal panel. These receptacles can be accessed in any voltage selector switch position. Each receptacle is protected by a 20 amp circuit breaker. These breakers are located directly above the GFCI receptacles.
DCA-36SPX — OUTPUT TERMINAL PANEL FAMILIARIZATION Over Current Relay Loads can be connected to the generator by the Ouput An over current relay (Figure 14) is connected to the main Terminal Lugs or the convenience receptacles (Figure 13). circuit breaker. In the event of an overload, both the circuit Make sure to read the operation manual before attempting breaker and the over current relay may trip. If the circuit breaker can not be reset, the reset button on the over curto connect a load to the generator.
DCA-36SPX — LOAD APPLICATION/MAXIMUM AMPERAGE Single Phase Load Always be sure to check the nameplate on the generator and equipment to insure the wattage, amperage, frequency, and voltage requirements are satisfactorily supplied by the generator for operating the equipment. Generally, the wattage listed on the nameplate of the equipment is its rated output.
DCA-36SPX — GAUGE READING/ TERMINAL PANEL CONNECTIONS How to Read the Output Terminal Gauges. The gauges on the control panel are provided to help observe how much power is being supplied at the Output terminals lugs. Reading Amperage To determine the amperage at a terminal lug, set the AC Ammeter Change-Over Switch to the appropriate setting (Figure 15) to activate the AC Ammeter Gauge (Figure 16) and read the available amperage at the terminal lug.
DCA-36SPX — SETUP Fuel Check Circuit Breakers To protect the generator from an overload, a 3-pole, 90 amp, main circuit breaker is provided to protect the U,O, and V Output Terminals from overload. In addition two single-pole, 20 amp GFCI circuit breakers are provided to protect the GFCI receptacles from overload. Two 50 amp load circuit breakers have also been provided to protect the auxiliary receptacles from overload.
DCA-36SPX — SETUP Refueling Procedure: NOTE WARNING - RESPIRATORY HAZARDS Diesel fuel and its vapors are dangerous to your health and the surrounding environment. Avoid skin contact and/or inhaling fumes. 3. 1. Level Tanks – Make sure fuel cells are level with the ground. Failure to do so will cause fuel to spill from the tank before reaching full capacity (Figure 22). If generator is equipped with an environmental fuel tank, reference Figures 24 and 25.
DCA-36SPX — SETUP Coolant (Antifreeze/Summer Coolant/Water) ISUZU recommends antifreeze/summer coolant for use in their engines, which can be purchased in concentrate (and mixed with 50% demineralized water) or pre-diluted. See the ISUZU Engine Owner's Manual for further details. Cleaning the Radiator The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air.
DCA-36SPX — SETUP Battery When connecting battery do the following: This unit is of negative ground DO NOT connect in reverse. 1. NEVER connect the battery cables to the battery terminals when the MPEC Control Switch is in either Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level are not the MANUAL position. ALWAYS make sure that the MPEC Control Switch is in the OFF/RESET position when properly maintained.
DCA-36SPX — GENERATOR START-UP PROCEDURE (MANUAL) Manual Start-up Procedure Before Starting CAUTION - LETHAL EXHAUST HAZARD The engine's exhaust contains harmful emissions. ALWAYS have adequate ventilation when operating. Direct exhaust away from nearby personnel. 1. Place the MPEC Control Switch in the MANUAL position to start the engine (Figure 30). WARNING - STARTING THE GENERATOR ISUZU NEVER! manually start the engine with the main, GFCI or auxiliary circuit breakers in the ON (closed) position.
DCA-36SPX — GENERATOR START-UP PROCEDURE (MANUAL) 6. The generator's AC-voltmeter (Figure 33) will display the generator’s output in VOLTS. If the voltage is not within the specified tolerance, use the voltage adjustment control knob (Figure 34) to increase or decrease the desired voltage. 9. The coolant temperature gauge (Figure 37) will indicate the coolant temperature. Under normal operating conditions the coolant temperature should be between 180~221 °F (82~105 °C), Green Zone. Figure 37.
DCA-36SPX — GENERATOR START-UP PROCEDURE (AUTO MODE) When starting generator in AUTO mode use the "Manual Start-up" procedure except where noted (see below). Starting (Auto Mode) DANGER - ELECTRICAL SYSTEM HAZARDS Before connecting this generator to any building’s electrical system, a licensed electrician must install an isolation (transfer) switch. Serious damage to the building’s electrical system may occur without this transfer switch.
DCA-36SPX — GENERATOR SHUT-DOWN PROCEDURES WARNING - SHUTTING DOWN THE GENERATOR NEVER stop the engine suddenly except in an emergency. Normal Shutdown Procedure To shutdown the generator use the following procedure: 1. Place both the MAIN, GFCI and LOAD circuit breakers as shown in Figure 39 to the OFF position. Emergency Shutdown Procedure 1. Place the MPEC Control Switch switch (Figure 42) to the OFF/RESET position. 2.
DCA-36SPX — MAINTENANCE 10 Hrs DAILY TABLE 11.
DCA-36SPX — MAINTENANCE Flushing Out Radiator and Replacing Coolant Air Removal If air enters the fuel injection system of a diesel engine, Open both cocks located at the crankcase side and at the lower part of the radiator and drain coolant. Open the starting becomes impossible. After running out of fuel, or after disassembling the fuel system, bleed the system radiator cap while draining. Remove the overflow tank according to the following procedure. See the VOLVO Engine and drain. Manual for details.
DCA-36SPX — MAINTENANCE Jacket Water Heater and Internal Battery Charger 120 VAC Input Receptacles (OPTIONAL) This generator can be optionally equipped with two 120 VAC, 20 amp input receptacles located on the output terminal panel. The purpose of these receptacles is to provide power via commercial power to the jacket water heater and internal battery charger. These receptacles will ONLY function when commercial power has been supplied to them (Figure 43).
DCA-36SPX — TRAILER MAINTENANCE 8. Tire Size - Indicates the diameter of the tire in inches (10,12,14, etc.), and the width in millimeters This section is intended to provide the user with generic (175,185,205, etc.). The tire diameter must match the trailer service and maintenance information. The service and diameter of the tire rim. maintenance guidelines referenced in this section refer to a wide range of trailers. 9. Tire Ply - The tire ply (layers) number is rated in letters; 2-ply,4-ply,6-ply, etc.
DCA-36SPX — TRAILER MAINTENANCE Brakes Trailer brakes should be inspected the first 200 miles of operation. This will allow the brake shoes and drums to seat properly. After the first 200 mile interval, inspect the brakes every 3,000 miles. If driving over rough terrain, inspect the brakes more frequently. Figure 44 displays the major hydraulic surge brake components that will require inspection and maintenance.
DCA-36SPX — TRAILER MAINTENANCE Tires/Wheels/Lug Nuts Tires and wheels are a very important and critical components of the trailer. When specifying or replacing the trailer wheels it is important the wheels, tires, and axle are properly matched. CAUTION - EYESIGHT HAZARD Suspension The leaf suspension springs and associated components (Figure 45) should be visually inspected every 6,000 miles for signs of excessive wear, elongation of bolt holes, and loosening of fasteners.
DCA-36SPX — TRAILER MAINTENANCE Lug Nut Torque Requirements It is extremely important to apply and maintain proper wheel mounting torque on the trailer. Be sure to use only the fasteners matched to the cone angle of the wheel. Proper procedure for attachment of the wheels is as follows: 1. Start all wheel lug nuts by hand. 2. Torque all lug nuts in sequence (see Figure 46). DO NOT torque the wheel lug nuts all the way down. Tighten each lug nut in 3 separate passes as defined by Table 15. 3.
DCA-36SPX — TRAILER WIRING DIAGRAM Figure 47. Trailer/Towing Vehicle Wiring Diagram PAGE 46 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX — GENERATOR WIRING DIAGRAM Figure 48. Generator Wiring Diagram 1 DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX — ENGINE WIRING DIAGRAM Figure 49. Engine Wiring Diagram PAGE 48 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX — TROUBLESHOOTING (ENGINE) Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 16 shown below for diagnosis of the engine. If the problem cannot be remedied, consult our company's business office or service plant. TABLE 16. ENGINE TROUBLESHOOTING SYMPTOM Engine does not star t. POSSIBLE PROBLEM SOLUTION No fuel? Replenish fuel. Air in the fuel system? Bleed system.
DCA-36SPX — TROUBLESHOOTING (ENGINE) TABLE 16. ENGINE TROUBLESHOOTING (CONTINUED) SYMPTOM POSSIBLE PROBLEM Engine revolution is not smooth. Either white or blue exhaust gas is observed. Either black or dark gray exhaust gas is observed. Deficient output. SOLUTION Fuel filter clogged or dir ty? Clean or change. Air cleaner clogged? Clean or change. Fuel leak due to loose injection pipe retaining nut? Tighten nut. Injection pump malfunctioning? Repair or replace.
DCA-36SPX — TROUBLESHOOTING (GENERATOR) Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 17 shown below for diagnosis of the generator. If the problem cannot be remedied, consult our company's business office or service plant. TABLE 17.
DCA-36SPX — TROUBLESHOOTING (ENGINE CONTROLLER) Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 18 (Engine Controller Troubleshooting) as a basic guideline for troubleshooting the Microprocessor Engine Controller unit (MPEC). If the problem cannot be remedied, consult our company's business office or service plant. TABLE 18. ENGINE CONTROLLER TROUBLESHOOTING (MPEC) SYMPTOM POSSIBLE PROBLEM Low oil pressure light is on.
NOTE PAGE 1 DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX — EXPLANATION OF CODE IN REMARKS COLUMN The following section explains the different symbols and remarks used in the Parts section of this manual. Use the help numbers found on the back page of the manual if there are any questions. NOTICE The contents and part numbers listed in the parts section are subject to change without notice. Multiquip does not guarantee the availability of the parts listed. SAMPLE PARTS LIST NO. 1 2% 2% 3 4 PART NO. PART NAME QTY. REMARKS 12345 BOLT.....................
DCA-36SPX — SUGGESTED SPARE PARTS DCA-36SPX WHISPER WATTGENRATOR W/ISUZU BB-4JG1T DIESEL ENGINE 1 TO 3 UNITS Qty. P/N Description 1 ......... M1310501003 .... HOSE, RADIATOR UPPER 1 ......... M1310501103 .... HOSE, RADIATOR LOWER 1 ......... 0602011053 ....... RADIATOR CAP 1 ......... 0605505070 ....... FUEL CAP 1 ......... 0602122272 ....... UNIT, OIL PRESSURE 1 ......... 0602123260 ....... UNIT, WATER TEMPERATURE 6 ......... 8953692993 ....... FILTER, FUEL CARTRIDGE 6 ......... 8970497081 .......
DCA-36SPX — GENERATOR ASSY. GENERATOR ASSY. PAGE 56 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX — GENERATOR ASSY. GENERATOR ASSY. NO. 1 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 1-9 1-10 1-11 1-12 1-13 1-14 1-15 1-16 1-17 2 3 4 4-1 4-2 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 25A 25B 26 27 PART NO.
DCA-36SPX— ENGINE OPERATING PANEL ASSY. ENGINE OPERATING PANEL ASSY. PAGE 58 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX— ENGINE OPERATING PANEL ASSY. ENGINE OPERATING PANEL ASSY. NO. 1 2 3 4 5 6 7 8 8A 9 10 11 11A PART NO. 0602202545 0601831340 0602120095 0602122093 0602123090 0602121080 0602125090 0602103092 0601810245 9826800370 0601831330 0027104040 0207004000 PART NAME QTY. REMARKS CONTROLLER, ECU-9988N 1 SWITCH 1 TACHOMETER 1 OIL PRESSURE GAUGE 1 WATER TEMPERATUR GAUGE 1 CHARGING AMMETER 1 FUEL GAUGE 1 ALARM LAMP 1 BULB, DC18V 1 PANEL LIGHT .................................................... 1 ...........
DCA-36SPX— CONTROL BOX ASSY. CONTROL BOX ASSY. (S/N 7800001~7800129) PAGE 60 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX— CONTROL BOX ASSY. CONTROL BOX ASSY. NO. 1 2 2-1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 PART NO.
DCA-36SPX— ENGINE AND RADIATOR ASSY. ENGINE AND RADIATOR ASSY. PAGE 62 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX— ENGINE AND RADIATOR ASSY. ENGINE & RADIATOR ASSY. NO. 1 1A 1-1 2 3 4 5 6 6-1 6-2 6-3 6-4 7 8 9 10 11 12 13 14 15 16 16A 17 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 PART NO.
DCA-36SPX— ENGINE AND RADIATOR ASSY. ENGINE & RADIATOR ASSY. PAGE 64 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX— ENGINE AND RADIATOR ASSY. ENGINE & RADIATOR ASSY. NO. 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 PART NO. 0802081104 0199100215 M1317100004 0016908020 0199100800 0193601200 0605515106 0602220910 0016908020 0199800700 0269200850 0605515198 RCT-2010 0016908020 0602120465 0602122272 M9200100004 0602123260 9095720140 1819001902 M1354200404 0027106016 0016908025 PART NAME QTY.
DCA-36SPX— OUTPUT TERMINAL ASSY. OUTPUT TERMINAL ASSY. PAGE 66 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX— OUTPUT TERMINAL ASSY. OUTPUT TERMINAL ASSY. NO. 1 2 3 4 5 6 7 8 9 10 11 11A 11B 12 12A 13 14 15 16 17 18 19 20 20-1 21 22 23 24 24A 25 26 27 28 29 30 31 32 33 PART NO.
DCA-36SPX— BATTERY ASSY. BATTERY ASSY. PAGE 68 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX— BATTERY ASSY. BATTERY ASSY. NO. 1 2 3 4 5 6 7 8 9 10 PART NO. 0602220187 B9310500004 M9103000304 0602220920 0040006000 M1346200004 M1347200104 0017110020 0040510000 PART NAME QTY. REMARKS BATTERY 1 BATTERY SHEET 1 BATTERY BAND 1 BATTERY BOLT SET ........................................ 2 ........... INCLUDES ITEM W/ # WASHER, LOCK 2 BATTERY CABLE 1 BATTERY CABLE 1 HEX HEAD BOLT 2 TOOTHED WASHER 2 BATTERY CABLE, GROUND ............................ 1 ...........
DCA-36SPX— MUFFLER ASSY. MUFFLER ASSY. PAGE 70 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX— MUFFLER ASSY. MUFFLER ASSY. NO. 1 2 3 4 5 6 7 8 9 10 11 PART NO. B3923200044 0016910025 M1333002503 8943690210 B3333200104 0039308000 0016908035 M1330400304 M1333300004 0016906015 0602326090 PART NAME QTY. REMARKS MUFFLER 1 HEX HEAD BOLT 4 EXHAUST PIPE 1 GASKET ........................................................... 1 ........... REPLACES P/N 0602320101 GASKET 1 HEX HEAD NUT 6 HEX HEAD BOLT 4 COVER 1 BRACKET 1 HEX HEAD BOLT 4 U-BOLT SET 1 1 DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX— FUEL TANK ASSY. FUEL TANK ASSY. PAGE 72 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX— FUEL TANK ASSY. FUEL TANK ASSY. NO. 1 2 3 4 5 6 7 7-1 8 9 10 11 12 13 14 14A 15 16 17 18 19 20 21 22 PART NO. M1363001602 0605505070 M1363200104 0805003414 0016908020 0207308000 0222100600 0222100085 1502025103 0802011104 0150000018 0016906020 M1363400104 0605515064 8943672922 8943692993 0016908020 0602220911 0016908020 0191201400 0191201600 0191301100 0605515108 0605515109 PART NAME QTY.
DCA-36SPX— ENCLOSURE ASSY. ENCLOSURE ASSY. PAGE 74 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX— ENCLOSURE ASSY. ENCLOSURE ASSY. NO. 1 2 3 4 4A 5 6 6A 7 8 9 10 11 12 12A 12B 13 13A 13B 14 14A 15 16 17 17A 18 19 20 21 22 22A 23 24 24A 25 26 27 27A 28 29 29A 30 33 33A PART NO.
DCA-36SPX— ENCLOSURE ASSY. (CONT.) ENCLOSURE ASSY. (CONT.) PAGE 76 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX— ENCLOSURE ASSY. (CONT.) ENCLOSURE ASSY. (CONT.) NO. 34 34A 34B 35 36 36A 37 37A 38 38A 39 39A 40 40A 41 41A 42 43 44 44A 45 46 47 48 48A 49 50 51 52 53 54 54A 55 55A 56 57 57-1 PART NO.
DCA-36SPX— RUBBER SEALS ASSY. RUBBER SEALS ASSY. PAGE 78 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
DCA-36SPX— RUBBER SEALS ASSY. RUBBER SEALS ASSY. NO. PART NO.
DCA-36SPX— NAMEPLATE AND DECALS ASSY. NAMEPLATE AND DECALS ASSY. PAGE 80 — DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
NAMEPLATE AND DECALS ASSY. DCA-36SPX— NAMEPLATE AND DECALS ASSY. NAME PLATE ASSY. NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 25 26 27 28 29 30 31 32 33 34 35 PART NO.
Effective: February 22, 2002 PAYMENT TERMS TERMS AND CONDITIONS OF SALE — PARTS 5. Parts must be in new and resalable condition, in the original Multiquip package (if any), and with Multiquip part numbers clearly marked. 6. The following items are not returnable: Multiquip reserves the right to quote and sell direct to Government agencies, and to Original Equipment Manufacturer accounts who use our products as integral parts of their own products. a.
NOTE PAGE 1 DCA-36SPX— OPERATION AND PARTS MANUAL — REV.
PARTS AND OPERATION MANUAL OPERATION AND PARTS MANUAL HERE’S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING MULTIQUIP CORPORATE OFFICE 18910 Wilmington Ave Tel. (800) 421-1244 Carson, CA 90746 Fax (800) 537- 3927 Contact: mq@multiquip.com Web: www.multiquip.com MQ Power 1800 Water Ridge Rd. Tel. (800) 883-2551 Suite 500/600 Fax (972) 315-1847 Lewisville, TX 75057 Contact: mqpower@multiquip.com Web: www.mqpower.