Starting Serial Number: SKU-09001001 Operating Instructions and Owner’s Manual Model # HS50K, HS75KT, HS125KT, HS175KT, HS210KT READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.
WARNING: WARNING: YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER. NOT FOR HOME OR RECREATIONAL VEHICLE USE WARNING: GENERAL HAZARD WARNING: FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.
SPECIFICATIONS CAUTION: CSA certified for use with only No. 1-K kerosene fuel. Model Burn Rate: Fuel Rate: Electrical Input: Line Protection: Min. Operating Voltage: Pressure Setting: Max. Outlet Temperature: Fuel Tank Capacity: Ignition: Spark Generator: Primary Safety Control: Certification: HS50K 50,000 Btu/hr (14.7 kW) 0.37 gal/hr (1.4 L/hr) 115V, 60Hz, 3.5a 10 amps 110V 3.5 psig (24 kPa) 1450oF (787oC) 4 gallons (15.
2. 3. 4. 5. a. Install one of the cotter pins into the hole on one end of axle. b. Slide the large washer, then wheel onto the axle next to the cotter pin. c. Slide the spacer onto the axle next to the wheel. d. Slide the partially assembled axle through the wheel support frame. e. Slide the spacer onto the axle next to the wheel support. f. Slide the wheel then large washer onto the axle and hold in place with the remaining cotter pin. g.
2. parts should be repaired or replaced before using heater again. Check heater operation to be sure it is operating normally (See “Servicing” section for description of normal operation). FILTERS. Dirty air or fuel filters will cause an imbalance in the air-fuel mixture. The best indication that this condition exists is an increase in odors or difficulty getting your heater to ignite. This heater should never be operated without the filters in place.
DIAGNOSTIC SAFETY SHUTDOWN AND TROUBLE SHOOTING These instructions are applicable for HS50K, HS75KT, HS125KT, HS175KT, HS210KT SYMPTOM TROUBLE SHOOTING High limit switch Open Circuit 1) Sparks, calling for flame, but 1) no or slow motor operation 2) 3) 4) 5) 6) 7) 8) 9) Make sure heater is cooled off, toggle switch to “OFF” position, wait 5 minutes and retry. Check wiring to motor (per wiring schematic in manual).
WIRING DIAGRAM 18AWG GRN 18AWG BLK 18AWG WHT HI-LIMIT SWITCH ON/OFF SWITCH 1 18AWG YELL 2 3 18AWG YELL CORD SET CAD CELL THERMOSTAT 18AWG BLUE 75KT,125KT,175KT,210KT ONLY FLAME CONTROL SCHEMATIC (connections may not be in same position on circuit board) M1 I1 18AWG PURPLE 17AWG BLK I2 ELECTR0DE L 18AWG ORG 18AWG ORG MOTOR 18AWG PURPLE 17AWG BLK N M2 COM1 H1 H2 18AWG GRN 18AWG PINK 18AWG PINK MOTOR CAPACITOR 18AWG RED IGNITION TRANSFORMER 18AWG RED The parts lists and wiring dia
PARTS LIST Ref.
Kerosene Forced Air Heater • Model HS50K, HS75KT, HS125KT, HS175KT, HS210KT 19 25 9 20 33 26 17 18 Filter Kit 24 48 41 23 11 49 22 3 30 39 40 21 37 16 35 4 34 7 29 5 12 10 14 38 6 28 36 27 45 47 8 31 32 13 15 1 43 2 46 42 44 Enerco Technical Products, Inc.
Operating Instructions and Owner’s Manual Model # HS50K, HS75KT, HS125KT, HS175KT, HS210KT WARNING: USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY. PARTS ORDERING INFORMATION: PURCHASING: Accessories may be purchased at any Mr.
Guide d'utilisation et instructions de fonctionnement Modèle n° HS50K, HS75KT, HS125KT, HS175KT, HS210KT AVERTISSEMENT : N'UTILISEZ QUE LES PIÈCES DE RECHANGE DU FABRICANT. L'UTILISATION D'AUTRES PIÈCES RISQUE DE CAUSER DES BLESSURES ET LA MORT. LES PIÈCES DE REMPLACEMENT NE SONT OFFERTES QUE PAR LE FABRICANT ET DOIVENT ÊTRE INSTALLÉES PAR UNE ENTREPRISE SPÉCIALISÉE. INFORMATIONS SUR LA COMMANDE DE PIÈCES : ACHAT : On peut se procurer des accessoires auprès de tous les détaillants locaux Mr.
Appareil de chauffage à air pulsé au kérosène • Modèles HS50K, HS75KT, HS125KT, HS175KT, HS210KT 25 19 9 20 33 26 17 18 24 Ensemble de filtre 48 41 23 11 OU Filtre à combustible 49 22 3 30 39 40 21 37 16 35 4 34 7 29 5 12 10 14 38 6 28 36 27 45 47 8 31 32 13 OU 15 1 43 2 46 42 44 9 Enerco Technical Products, Inc.
LISTE DES PIÈCES Réf.
SCHÉMA DE CÂBLAGE VRT AWG 18 INTERRUPTEUR MARCHE-ARRÊT NOIR AWG 18 BLC AWG 18 INTERRUPTEUR COMMANDE MAX.
DIAGNOSTIC ET DÉPANNAGE APRÈS UN ARRÊT D'URGENCE Ces instructions s'appliquent aux modèles HS50K, HS75KT, HS125KT, HS175KT, HS210KT 1) Assurez-vous que la longueur et le calibre de la rallonge électrique sont conformes aux spécifications (voir page 4). Vérifiez le câblage vers l'allumeur (selon le schéma de câblage du présent guide). Vérifiez l'écart entre les pointes d'électrode (2,3 - 3 mm). S'il n'y a toujours pas d'étincelle, remplacez l'allumeur. Remplacez l'ensemble commande de flamme.
5. la pression ou desserrez-la pour réduire la pression. Les pressions nominales sont indiquées dans le tableau des spécifications à la page 3 du Guide d'utilisation et instructions de fonctionnement. Pour une efficacité maximale, le cône avant de la chambre de combustion doit être rouge cerise sans présenter de taches foncées, et la flamme ne doit pas se prolonger audelà du cône. 1. 5. déséquilibrera le mélange air-combustible et produira un surplus de fumée et d'odeur.
INSTRUCTIONS DE FONCTIONNEMENT DÉBALLAGE 1. Retirez l'appareil de chauffage de la boîte. 2. Enlevez tout le matériel de protection installé sur l'appareil pour le transport. 3. Vérifiez soigneusement tout dommage qu'aurait pu subir l'appareil de chauffage pendant l'expédition. Si vous constatez quelque dommage, avisez immédiatement le fabricant au 1 800 251-0001. ASSEMBLAGE (Pour modèles de 125 000, 175 000 et 210 000 BTU/h uniquement, voir la figure 1, page 8.
SPÉCIFICATIONS PRUDENCE : CSA certifié pour l’utilisation avec seulement No. 1-K le combustible de pétrole. Modèles HS50K HS75KT HS125KT HS175KT HS210KT Taux de combustion : 50 000 Btu/h (14.
AVERTISSEMENT : VOTRE SÉCURITÉ PERSONNELLE ÉTANT IMPORTANTE POUR TOUS, VEUILLEZ LIRE LES INSTRUCTIONS AVANT D'UTILISER CET APPAREIL DE CHAUFFAGE. AVERTISSEMENT GÉNÉRAL DE DANGER : LE NON-RESPECT DES MESURES DE PRÉVENTION ET INSTRUCTIONS FOURNIES AVEC CET APPAREIL DE CHAUFFAGE RISQUE DE CAUSER LA MORT, DES BLESSURES GRAVES ET DES DOMMAGES OU DES PERTES MATÉRIELLES RÉSULTANT D'INCENDIE, D'EXPLOSION, DE BRÛLURE, D'ASPHYXIE, D'INTOXICATION AU MONOXYDE DE CARBONE OU D'ÉLECTROCUTION.
Guide d'utilisation et instructions de fonctionnement Numéro de série : SKU-09001001 Modèle n° HS50K, HS75KT, HS125KT, HS175KT, HS210KT LISEZ SOIGNEUSEMENT LES INSTRUCTIONS. Lisez et observez toutes les instructions. Conservez les instructions pour vous y référer ultérieurement. Interdisez à quiconque n'ayant pas lu les présentes instructions d'assembler, d'allumer, de régler ou de faire fonctionner cet appareil de chauffage.