OPERATING INSTRUCTIONS
PREPARING FOR OPERATION
enclosed instructions sheet before lighting or operating the
heater.
found, immediately notify the factory.
3. Follow all of the Safety and Operating Precautions.
4. Connect the POL fitting of hose and regulator assembly
to the propane cylinder by rotating the POL nut
securely tighten with a wrench.
5. Connect the hose to the heater.
6. Securely tighten all gas connections.
with a soap and water solution. DO NOT USE A FLAME.
START
1. WARNING: BEFORE LIGHTING PILOT, fully close the ball
seconds before Step 3.
3. Depress red button on safety pilot valve admitting gas to the
heater. Then push and release the ignition button until the
pilot lights.
4. When the pilot lights, continue to hold the button depressed
for 30 seconds, then release.
5. If pilot goes out, wait 5 minutes and repeat the lighting
procedure.
to regulate heat output.
CAUTION: ADJUSTING BURN RATE too low can cause soot.
STOP
1. Securely close valve on the propane cylinder.
burned.
3. Fully close the ball valve.
RESTART AFTER SAFETY SHUTDOWN
1. Securely close valve at propane cylinder.
3. Restart following "Start" procedure.
SERVICING
A hazardous condition may result if a heater is used that has
been modified or is not functioning properly. When the heater is
* The flame is contained within the heater.
* The flame is essentially blue with perhaps some yellow tipping.
* There is no strong disagreeable odor, eye burning or other
physical discomfort.
heater.
constructed. Do not use a heater which is different from that
shown. In this regard, use only the hose, regulator and cylinder
IMPORTANT Match the color stripe on the hang tag attached
to the hose assembly with the color on the label located near
the propane inlet fitting on the heater. Do not use alternates. For
this heater, the regulator must be set as shown in "specifications".
If there is any uncertainty about the regulator setting, have it
A heater which is not only by
parts or labor. Please include a brief statement indicating date,
place of purchase, the nature of the problem and proof of
purchase.
and labor.
MAINTENANCE AND STORAGE
1. The heater should be inspected before each use, and at least
annually by a qualified person.
of the POL fitting. If the "O" ring is cut, scuffed, or otherwise
damaged, replace it with part number 6681.
heater is not in use.
4. When the heater is to be stored indoors, the connection
and stored out of doors and in accordance with Chapter 5 of
the standard for Storage and Handling of Liquefied Petroleum
Propane Installation Code.