Manual

10
Installation Instructions and Owner’s Manual
Unvented Natural Gas Vent Free Room Heaters
Pressure Testing Heater Gas Connections:
1.  Make sure that the heater supply piping system 
is connected and has been leak tested as 
described above.
2.  Make sure control knob of heater is in OFF 
position.
3.  Open equipment shutoff valve (see fi gure 13). 
4.  Open main gas valve on or near gas meter.
5.  Check all joints from equipment shutoff valve 
to control valve (see fi gure 14). Apply mixture 
of liquid soap and water to gas joints. Bubbles 
forming show a leak.
6.  Correct all leaks at once.
7.  Light heater (see Operating Your Heater, pages 
10 and 11. Check the rest of the internal joints 
for leaks. 
8.  Turn off heater (see To Turn OFF Gas to 
Appliance, page 11.
9.  Replace lower front panel. 
Figure 13
Figure 14
Equipment 
Shutoff Valve
Open
Closed
ELECTRICAL WIRING DIAGRAM:
If any original wiring as supplied with the heater must 
be replaced, it must be replaced with type AWG 105
o
C 
wire or its equivalent except as indicated.
WARNING: Electrical Grounding Instructions: This 
heater is equipped with a three-prong (grounding) 
plug for your protection against shock hazard and 
should be plugged into a properly grounded three-
prong receptacle. 
OPERATING YOUR HEATER
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions 
exactly, a fi re or explosion may result causing 
property damage, personal injury or loss of life. 
A.  This appliance has a pilot which must be lighted 
by pushing the ignitor button. When lighting the 
pilot, follow these instructions exactly.
B.  BEFORE LIGHTING smell all around the 
appliance area for gas. Be sure to smell next to 
the fl oor because some gas is heavier than air 
and will settle on the fl oor.
WHAT TO DO IF YOU SMELL GAS
•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use 
any phone in your building.
•  Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas supplier’s 
instructions.
•  If you can not reach your gas supplier, call the 
fi re department.
C.  Use only your hand to push in or turn the gas 
control knob. Never use tools. If knob will not 
push in or turn by hand, don’t try to repair it call 
a qualifi ed service technician or gas supplier. 
Force or attempted repair may result in a fi re or 
explosion.
Control Valve
Equipment 
Shutoff Valve
To gas meter
Figure 15
Caution: Label all wires prior to 
disconnection when 
servicing controls. 
Wiring errors can cause 
improper and dangerous 
operation. Verify proper 
operation after servicing.