Specification

3”
2
3
/
4
3
1
/
2
3”
1”
0 3”
7
/
8
Even distribution of steam while
remaining cool to the touch
No field assembly required
No moving parts
Integrated aromatherapy oil
well for in shower use
Installing the Round & Square Steamhead
STEAMHEAD INSTALLATION (
1
2" NPT)
IMPORTANT: Do not disassemble steamhead. Mr.Steam’s steam
head is shipped fully assembled and requires no additional assembly.
Because the steamhead and direct steam emissions
are very hot, locate the steamhead where incidental contact by
bather with the steamhead or direct steam emission cannot occur.
NOTE: A 1.5” clearance hole around the steam pipe is needed
to mount the steamhead.
Locate steamhead 6-12 inches above floor, except for:
Tub/shower enclosures, install 6 inches above tub top edge.
For enclosures with acrylic or other non-heat resistant flooring
install Acrylic Shield Part Number 103938 /10398SQ
IMPORTANT NOTE: To preserve steam head finish, do not
use wrench or other tools to tighten. DO NOT use abrasive
cleansers or chemicals. Use only water with mild soap and a
non-abrasive sponge.
!
C A U T I O N
mr
.
steam
®
Technical Specifications
AromaSteam Steamhead ROUND 103937 / SQUARE 104040 / ISTEAM104104
TS0010 REV 5.14
mr
.
steam
®
Sussman-Automatic Corp®
hello@mrsteam.com www.mrsteam.com
43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256
9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944
S
team
S
upply Pipe
End of pipe to be recessed
1/4" (without Acrylic Shield)
1/8" (with Acrylic Shield)
1/8"
m
inimum clearance
r
equired when Acrylic Shield
i
s used. See installation
i
nstructions provided with the
A
crylic Shield.
Apply with silicone
or equal sealant as
required for
moisture seal.
Use Teflon
®
or
e
qual sealant on
pipe threads
MODEL FINISH PROJECT INFORMATION
103937-Round
BB Brushed Bronze
104040-Square
BN Brushed Nickel
104104-iSteam*
ORB Oil Rubbed Bronze
PB Polished Brass
PC Polished Chrome
PN Polished Nickel
RAW
Custom Plating
BLK Black**
WH White**
Location:
Architect:
Engineer:
Contractor:
Submitted By:
Date:
Notes:
*iSteam steamhead is only available in black and white ** Black and white finish are only available with iSteam steamhead
Consult with supplier of acrylic, fiberglass
and other non-heat resistant enclosures for recommended
steamhead location. Use Acrylic Shield PN 103938/
103938SQ. See instructions provided with steam shield. (An
acrylic shield is not available for the iSteam steamhead.)
!
C A U T I O N
FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION
visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and
Maintenance Manual or refer to the manual provided with the unit.

Summary of content (1 pages)