Instructions / Assembly

1. Locate steambath generator within 60 feet of
steam room.
Note: The standard length of the cable for
connecting the control to the steam generator
is 30 feet. The steam generator and control
must be located accordingly. A 30 foot cable
is standard. Contact Mr.Steam to purchase
an optional 60 ft. cable (PN 103990-60) for
iTempo controls. A 60 foot cable is available
for use with iSteam controls (PN 104117-60).
2. DO NOT install steambath generator inside
steam room.
3. DO NOT install steambath generator out
-
doors or wherever environmental conditions
may affect the safety and/or performance of
the generator.
4. DO NOT install steambath generator or
plumbing lines in unheated attic or any
location where water could freeze.
5. DO NOT install steambath generator near
flammable or corrosive materials or chemicals
such as gasoline, paint thinners, or the like.
Installation in areas having high concentrations
of chlorine (such as pool equipment room)
must be avoided.
6. Install steambath generator on a solid and level
surface. Keyhole slots are provided for wall
mounting. Insure the steam generator is prop
-
erly secured and level when mounting with
keyhole slots.
7. Install steambath generator in an upright
position only.
8. Install a Pressure Reducing Valve to limit supply
to 15-20 PSIG. MrSteam part number 104198.
9. Install anti-water hammer device as necessary.
10. Provide a minimum of (12) inches at both
ends and top of the steam generator or as
required for servicing.
GENERATOR LOCATION
2
For Illustrative purposes only. Consult with qualified designer,
architect or contractor for steamroom construction details.
LOCATING THE MR.STEAM
®
GENERATOR
Select a location as near as practical to the steam room. Typical locations include: closet,
vanity cabinet, climate controlled attic or basement.
IMPORTANT The information in this guideline is designed to provide a general overview of how MrSteam products are installed. The diagrams are for Illustrative purposes only. NEVER use this document for the Installation,
Operation or Maintenance of any MrSteam product. For Installation, Operation and Maintenance information, only use the specic Installation, Operation and Maintenance manual supplied with each Mr. Steam product. The
specic Installation, Operation and Maintenance manual that is supplied with each Mr. Steam product contains important information required for the safe and reliable installation and operation of the product. Failure to use
the specic Installation, Operation and Maintenance manual that is supplied with each Mr. Steam product may result in product damage, property damage, death or personal injury. If you do not have an Installation, Operation
and Maintenance manual please contact MrSteam for a free copy, or download a copy from www.mrsteam.com. If you have any questions about the installation, operation or maintenance of any MrSteam product please
contact a customer or technical service representative using the contact information on the back cover of this guideline.