Parts List:
Item # Description Used on
104208BK Electronic Assembly Black All
104208WH Electronic Assembly White All
104209 Retention Ring Flush Mount
(AirTempo Flush)
104210 Flush Mount Box Flush Mount
(AirTempo Flush)
104211 Surface Mount Holder Surface Mount
(AirTempo Surface)
104212 Wireless Receiver All
104213XX Round Beze
l Flush mount
(AirTempo Flush)
(specify finish)
104214XX Square Bezel Flush mount
(specify finish)
104215XX Surface Bezel Surface mount
(AirTempo Surface)
(specify finish)
104220 AirTempo Cable All
104117-30 30 Foot Cable Optional
103990-60 60 Foot Cable Optional
Technical Specifications:
Wireless Receiver Unit
Temperature operating -20 C ~ +50 C
Temperature storage -40 C ~ +85 C
Humidity 90%RH non-condensing
Usage type Indoor
Dimensions 41.5 x 117.5 x 22.5 mm (1.625 x 4.875 x 0.875 in.)
Operating frequencies 865 ~ 868 MHz (European Version)
910 ~ 920 MHz (North American Version)
Operating voltage 5.0 V
(
provided by Steam Generator Unit
)
AirTempo Control Unit
Temperature operating -20 C ~ +60 C
Temperature storage -30 C ~ +60 C
(limited by battery & LCD
)
Humidity 100%RH condensing (
external surface only
)
IP Rating IPX5
Usage type Indoor
Dimensions 90.0 x 90.0 x 19.0 mm
(
without decorative bezel)
(3.625 x 3.625 x 0.75 in. )
Operating frequencies
865 ~ 868 MHz (European Version)
910 ~ 920 MHz (North American Version)
Operating voltage 3.0 V
Battery Type CR2450 Primary Manganese Dioxide Lithium Batteries
(replace only with battery UL1642 approved
)