Planning Guide
“First things first, I need to size my Steam Generator.”
Generator SmartSizing
TM
1 Measure length, width & height of the steam
enclosure (in feet):
Multiply
Length ___ x Width____ x Height ____
ROOM VOLUME =
2 Construction Materials:
For natural stones: Add 110%
natural marble, stone,
shale, glass block or concrete.
For ceramic or porcelain
tile on cement board Add 40%
or mortar bed.
Ceilings above 8 ft Add 15%
(per foot, max 10 feet)
3 Add all gures (from the left) to obtain the
Total Room Volume required
TOTAL VOLUME
Compare your TOTAL ADJUSTED ROOM VOLUME to the
Specication Chart for Residential (below) and select the
appropriate model.
For Illustrative purposes only. Consult with qualified designer,
architect or contractor for steamroom construction details
and proper product placement.
1
Residential Steam Generators Specifications Chart
Product
Model No.
Total Room Amps Water Usage* Shipping
Volume (cu.ft.)
kW
240/1PH Gallons Wt.(lbs.)
MS90E up to 100 5 21 0.67 30
MS150E 101-150 6 25 0.80 30
MS225E 151-225 7.5 32 1.0 30
MS400E 226-360 9 38 1.2 30
MSSUPER1E 361-475 10 42 1.4 40
MSSUPER2E 476-575 12 50 1.6 40
MSSUPER3E 576-675 15 63 2.0 40
MSSUPER4E 676-875 20 84 2.7 80
MSSUPER5E 876-1075 24 100 3.2 80
MSSUPER6E 1076-1275 30 125 4.0 80
MSSUPER4E to 6E
17” x 18.5” x 7.9” (each)
MS90E to 400E
14.5” x 14.75” x 6.75”
MSSUPER1E to 3E
17” x 18.5” x 7.9”
To make sure you have just the right amount of steam for your new home
spa experience, use the chart below to help dene the shower size and
nish materials to determine the correct steam generator size.
Or simply visit VirtualSpa.MrSteam.com, it will do the math
for you and take you step-by-step through the whole steam
shower selection process.
Consult with a qualified designer, architect or contractor for steam room construction details.
Dimensions
* Water usage based on 20 minutes of operation.
Occasionally a steam room has unforeseeable or hidden construction that warrants special sizing or other consideration. MrSteam is not responsible if unconventional
and/or unforeseeable materials or construction details result in a unit that does not operate to specication. Refer to the applicable MrSteam Installation, Operation &
Maintenance Manual, available at mrsteam.com, and consult a properly licensed contractor, architect and/or design professional.
Failure to do so may result in an inoperable or hazardous condition. See product packaging and labeling for additional important information.