AromaSteam Installation Sheet
mr
.
steam
®
AromaSteam Operation and Installation Instructions
______________________________________________________________________________________________
Electrical Connection of
AromaSteam System
AromaSteam
Plug
120 VAC
Outlet
(grounded receptacle
required)
Request Cable
24 VAC
to steam generator
(see below)
AromaSteam Wiring
Schematic
AromaSteam Connections
CAUTION
!
This AromaSteam system is factory wired. If the
power cord of the Aroma Steam system is damaged it must be
replaced by the Sussman-Automatic service department or similar-
ly qualified personnel in order to avoid an electric shock hazard.
All electrical connections to be made by a licensed, qualified elec-
trician. Disconnect all power to the steam generator before
making power connections.
IMPORTANT NOTE:
AromaSteam is for use with AirTempo
®
iSteam
®
and iTempoPlus
®
controls only.
1. Disconnect all power to the MrSteam steam bath generator
and remove the top cover.
2. Run the request cable from the AromaSteam System through
one of the knock outs in the side of the steam bath generator.
Use a strain relief bushing or grommet to prevent chafing.
3. Locate the two quick connect tabs labeled "AROMA" on the
PC board in the location show.
4. Connect the request cable to the terminals. The terminals are
not polarized.
6
Injector
Soft Injector Tubing
Priming Valve Knob
START-UP
Initial Priming of the Pump
1. Insure MrSteam scent container is full.
2. Insert a short piece of soft injector hose onto the tip of the injector
(see Fig. 5).
3. Insert the open end of the injector hose onto the pressure valve
(see Fig. 5).
4. Open the priming valve by turning the knob counter clockwise 1
full revolution.
5. Draw liquid from the injector slowly and evenly. Continue until the
injector is full of liquid.
6. If you have drawn up the injector completely and no liquid is in
the injector, remove the injector hose from the pressure valve.
7. Drain injector. Repeat steps until the injector is filled.
8. Save the oil injector as it will be needed when new oils are used.
9. Close the priming valve completely by turning the knob clockwise.
Failing to close the valve will result in oil leaking from
the priming port.
Filling the Pressure Hose
1. Insure the AromaSteam System is primed and the scent
container is full.
2. Insert the open end of the injector into the pressure hose.
3. Draw liquid from the injector slowly and evenly.
Continue until the pressure hose if full of liquid.
Figure 5