Instructions / Assembly

STEAM OUTLET
5
Steam Outlet
Pipe
For Illustrative purposes only. Consult with qualified designer,
architect or contractor for steamroom construction details.
Steam Outlet (1/2” NPT)
1. Please provide a 1/2” copper or brass union on steam line.
2. Use 1/2”- brass pipe or rigid copper tubing from unit to steam head as permitted by codes.
3. Insulate steam line using pipe insulation rated 250˚ F or higher (for example Fiberglass).
4. Pitch steam line
1/4” per foot towards steam head or steam generator to avoid valleys and trapping
of condensate.
NOTE: Running the steam line down and then up will create a steam trap blocking the flow of steam.
NOTE: A 1.5” hole in the steamroom is required to mount the steamhead or 12 1/8” x 5/8” for
Residential Linear steamhead Part#104216.
STEAM OUTLET PIPE
IMPORTANT The information in this guideline is designed to provide a general overview of how MrSteam products are installed. The diagrams are for Illustrative purposes only. NEVER use this document for the Installation,
Operation or Maintenance of any MrSteam product. For Installation, Operation and Maintenance information, only use the specic Installation, Operation and Maintenance manual supplied with each Mr. Steam product. The
specic Installation, Operation and Maintenance manual that is supplied with each Mr. Steam product contains important information required for the safe and reliable installation and operation of the product. Failure to use
the specic Installation, Operation and Maintenance manual that is supplied with each Mr. Steam product may result in product damage, property damage, death or personal injury. If you do not have an Installation, Operation
and Maintenance manual please contact MrSteam for a free copy, or download a copy from www.mrsteam.com. If you have any questions about the installation, operation or maintenance of any MrSteam product please
contact a customer or technical service representative using the contact information on the back cover of this guideline.