READ ME FIRST! ! WARNING As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and operation of this generator. These are types of potential hazards that may occur during installation and operation: ! WARNING Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury.
RESIDENTIAL STEAMBATH GENERATOR SYSTEMS INSTALLATION, OPERATION MODEL _______________________________ & MAINTENANCE MANUAL MODELS: MS-90E, MS-150E, MS-225E, MS-400E, MS-SUPER 1E, MS-SUPER 2E, MS-SUPER 3E, MS-SUPER 4E, MS-SUPER 5E, MS-SUPER 6E TABLE OF CONTENTS Important Safety Instructions . . . . . . . . . . . . . Inside front cover Select Your Mr.Steam Model . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Generator Specification Chart . . . . . . . . . . . . . . . . . . . . . . . . .
mr Installation, Operation & Maintenance Manual .steam __________________________________________________________________________ ® SELECT YOUR MR.STEAM ! WARNING In considering the purchase or use of this steambath system, please note that if you are pregnant, have a coronary condition, are in poor health, are being treated for any other medical condition, or are using medication or drugs, Mr.Steam recommends that you obtain the approval of a physician before use.
® BEFORE INSTALLING the steambath room. Pay particular attention to room volume and construction. If any questions, please refer to Mr. Steam sizing and selection guide on page 2. Carefully inspect the Steam Generator and packaging for shipping damage. In the event of shipping damage, please contact the carrier for claim information. Our customer service department can assist you with any missing or damaged parts. 3. Marble or glass walls or ceilings.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam __________________________________________________________________________ ® WATER QUALITY INFORMATION For optimum results, the water supply should be tested prior RECOMMENDED FEEDWATER QUALITY Hardness, ppm 8 – 85 (~0.5 – 5 gpg) P-Alkalinity, ppm 85 – 410 (~5 – 24 gpg) T. Alkalinity, ppm 200 – 500 (~7 – 0 gpg) pH (strength of alkalinity) 8.0 – 11.4 to installation.
® TYPICAL MR.STEAM INSTALLATION ! CAUTION The control features an integral temperature sensor. Locate the control in a location representative of the desired steambathing temperatures. Do not locate the control above or near the steam head or direct steam emissions. NOTE: Drawings for illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction details.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam __________________________________________________________________________ ® INSTALLATION PLUMBING All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable National and local codes. 1. Use unions on all pipe connections. 2. Use only brass piping or copper tubing as permitted by codes. 3. DO NOT use black, galvanized, PVC pipe or PEX. WAT E R S U P P LY ( 3 ⁄8 " N P T ) 1.
® INSTALLING THE ROUND OR SQUARE AROMASTEAM STEAMHEAD (1⁄2" NPT) 1/8" minimum clearance required when Acrylic Shield is used. NOTE: A 1 ⁄2" clearance hole around the steam pipe is needed to mount the steamhead. STEP 1 Locate steam head 6-12 inches above floor, except for: 1. Tub/shower enclosures, install 6 inches above tub top edge. 2. For enclosures with acrylic or other non-heat resistant flooring install Acrylic Shield Part Number MS-103938.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam __________________________________________________________________________ ® GENERATOR DIAGRAM E D Water Inlet Control & Accessory Connections C Steam Outlet Safety Valve B Optional AutoFlush A Manual Drain Valve 12”” for servicing JJ F M K L G H IMPORTANT NOTES: Provide a minimum of (12) inches at both ends and top of the steam generator or as required for servicing.
® ELECTRICAL CHART ________________________________________________________________________________________________________ ELECTRICAL Max Room Vol Model No. (Cu. Ft.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam __________________________________________________________________________ ® INSTALLATION INSTRUCTIONS FOR MODELS: MS-SUPER 4E, MS-SUPER 5E AND MS-SUPER 6E 1. Install each unit as in a single installation. Install the two generators as close to each other as possible. 2. ! WARNING Shock Hazard. Power must be disconnected at the main electrical supply before removing steam generator covers. 3.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam __________________________________________________________________________ ® INITIAL START-UP AND CHECKOUT 1. Turn on control. Follow specific instructions provided with controls. 2. Steam will begin to appear in approximately 5 minutes (unless equipped with factory-installed Express Steam option) at the steam head.
® SYSTEM STATUS CODES The control (either iSteam®, iTempo™ or iTempo/Plus™) may display a status code if the steam generator is not functioning properly. Code H20 Code Meaning Water level is not satisfied within 5 min. Probable Cause Suggested Remedy Water Supply is off Turn on Water Supply Defective water feed solenoid Check/replace water solenoid valve Water feed probe not functioning Check/clean probe. Check probe wiring.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam __________________________________________________________________________ ® OPTIONAL AUTOFLUSH® Steam Generator Box Contents AutoFlush Valve with Cord Installation Instructions. 3 Pin Connector for AutoFlush OPERATION The optional AutoFlush System feature automatically drains the Mr.Steam generator following each use.
® OPTIONAL DRIP PAN Mr. Steam strongly recommends the use of a drip pan in the unlikely event of a plumbing leak. Locate the drip pan on a solid level surface and place the steam generator inside the drip pan. Insure the steam generator is level (see page 4 for locating the steam generator). All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable national and local codes. Check local plumbing code for receptor, trap and vent requirements.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam __________________________________________________________________________ ® PARTS IDENTIFICATION DIAGRAMS Contactor Liquid Level Control Board MS REGULAR MODELS Liquid Level Probe MS65E - MS400E (with AutoFlush™) shown with cover removed Transformer Water Feed Solenoid Power Supply Knock-Out Water Inlet Plug and Play Connection (see page 13) Steam Outlet Access Cover NOTE: FOR ILLUSTRATIVE PURPOSES ONLY.
® REPLACEMENT PARTS LIST __________________________________________________________________________________________ Part No.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam __________________________________________________________________________ ® CONTROL INSTALLATION Refer to Control Manual for specific installation requirements BEFORE INSTALLING Turn power to the steam generator OFF before connecting the control to the generator. Failure to turn the power off will result in an inoperable control.
mr.steam Installation, Operation & Maintenance Manual __________________________________________________________________________ ® H O M E O W N E R READ ME FIRST! ! WARNING As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and operation of this generator.
HOMEOWNER mr Installation, Operation & Maintenance Manual .steam __________________________________________________________________________ ® CARE TIPS FOR ALL CONTROLS AND STEAMHEADS 0SETTING THE STEAM BATH TEMPERATURE AND DURATION 1. Use only mild soap and water on a soft cloth to clean the control and steamhead. 2. DO NOT use abrasive cleansers. 3. If the decorative cover is damaged on the iTempo or iTempo/Plus call Mr.Steam technical service for replacement parts.
® ® USING MR.STEAM ESSENTIAL OILS Enjoy AromaSteam essential oils by placing a drop or two into an unheated AromaSteam steamhead as shown in the illustration. Only use Mr.Steam AromaSteam essential oils in the Mr.Steam AromaSteam steamhead. AromaSteam 10ml bottle with integrated dropper ! WARNING Essential oils and/or aroma therapy can cause inflammation, burns, headache, nausea and allergic reactions. Consult a physician before using aroma therapy. Recess for essential oil ! CAUTIONS 1.
mr.steam ® Feel Good Inc. ™ www.mrsteam.com Products, information and specifications are subject to change without notice. Please call Sales & Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information. mr.steam ® Sussman-Automatic Corporation® I hello@mrsteam.com I www.mrsteam.com 9410 S. La Cienega Blvd.
Installation, Operation & Maintenance Manual ® iSteam 2.0 Control mr.steam ® Feel Good Inc.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: READ ME FIRST! ! WARNING As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and eff icient installation and operation of this generator.
Table of Contents: Box Contents: Important Safety Instructions......................... 2 • iSteam 2.0® Control Installation Template .................................... 2 • Control Cable (30 ft.) Box Content.................................................. 3 • Steamhead Dimensional Information............................... 3 • Tube of Silicone Sealant Before Installing............................................. 4 • Owner’s Manual Locating the Control.....................................
mr Controls .steam __________________________________________________________________ ® Before Installing ! ! WARNING To avoid unintentional steambath op- Do not route iSteam 2.0 control wiring inside conduit together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation. Do not alter or modify any Mr. Steam products including the steam generator or iSteam 2.0 control.
mr Controls .steam __________________________________________________________________ ® Locating the Control 1b Determine the desired installation location of the control. The iSteam 2.0 controls are designed to be installed inside or outside the steam room as a matter of personal preference. If the control is installed inside the steam room: • Locate the control 4-5 feet above the floor near the bather seating area. • The control features an integral temperature sensor.
mr Controls .steam __________________________________________________________________ ® Installation with Optional Rough-In Box (cont.) IMPORTANT NOTE: Be careful not to strain, staple, pinch or otherwise damage the cables. Route cables as required to permit replacement. Do not route cables inside conduit together with power lines or close to hot water or steam piping. 6b Step 6 When used, route the AudioWizard™ Cable (6a) through a second knockout in the rough-in box and clip (6b).
mr Controls .steam __________________________________________________________________ ® Installation Instructions for iSteam 2.0® Step 1 PLUG the 30’ control cable into the iSteam 2.0 control pigtail (1a). The iSteam 2.0 pigtail is the longer cable with the ID Tag. If the optional AudioWizard™ is used, remove the Red Cap from the AudioWizard pigtail (1b) and plug it into the AudioWizard cable.
mr Controls .steam __________________________________________________________________ ® Installation Instructions for iSteam 2.0® (cont.) Step 2 2a Peel the double stick adhesive off the back of the iSteam 2.0 control (2a). Apply a bead of silicone around the rear of the iSteam 2.0 control to create a moisture seal (2b). Carefully feed the cables into the rough-in box and secure the control to the wall. Care must be taken to not pinch the cables. Ensure the control is level. IMPORTANT NOTE: The iSteam 2.
mr Controls .steam __________________________________________________________________ ® Operating Instructions ! WARNING Set the steam bathing duration and tem- perature according to personal preference, however it is highly recommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels. Set the duration at 10 minutes max. to gauge comfort and safety levels. This will allow the steam generator to heat up and begin producing steam.
mr Controls .steam __________________________________________________________________ ® Set Temperature Screen Press the TEMPERATURE button on the Dashboard to access the SET TEMPERATURE screen. The control is preset and will display a temperature setting of 110° F (default setting). Swipe your finger from left to right to adjust the desired temperature (80 ̊ - 120 ̊ F) in one degree increments. Press CANCEL to return to the Dashboard without changing the time.
CANCEL HOME F SAVE C ˚F / ˚C TOGGLE TEMP mr Controls .steam __________________________________________________________________ ® F Optional Accessories Screen Press the ACCESSORIES button on the START screen to access the optional ChromaSteam® and AudioWizard™ accessories when a steambath is not in session. See page 10 for information on the ChromaSteam and AudioWizard operation.
mr Controls .steam __________________________________________________________________ ® Settings > Passcode The Passcode feature can help prevent unintentional use of the steambath. Please refer to the steam generator Installation, Operation and Maintenance manual (PN 100472) before using the steam bath. The Passcode feature cannot insure unintentional use of the steambath. Enter a 4 digit passcode using the keypad. Press the passcode lock button ON under the 4 digit code to turn the passcode lock on.
mr Controls .steam __________________________________________________________________ ® iSteam 2.0 App IMPORTANT NOTE: Only one smart device can control iSteam 2.0 at a time. To use more devices the App must be closed on all other device. To use iSteam 2.0 from another device, simply press search for iSteam 2.0 after the iSteam 2.0 has been configured. Configuring the iSteam 2.0 only needs to be done once. The iSteam 2.0 App can be downloaded from the App Store or Google Play.
mr Controls .steam __________________________________________________________________ ® User Settings Set Temperature Screen Pressing the User 1, User 2 or User 3 button before pressing the START button will automatically load the user settings. User 1 and User 2 settings are stored in iSteam 2.0 and cannot be adjusted from the App. User 3 settings are stored in the app. To adjust the User 3 settings, press and hold the User 3 button.
mr Controls .steam __________________________________________________________________ ® Care Tips Use only mild soap and water on a soft cloth to clean the control. Do not use abrasive cleansers Safety and Operating Information ! WARNING Set the steam bathing duration and tempera- ture according to personal preference, however it is highly recommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels. Set the duration at 10 minutes max.
mr.steam ® Feel Good Inc. www.mrsteam.com Products, information and specifications are subject to change without notice. For more information call Sales & Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information. mr.steam ® Sussman-Automatic Corporation® I hello@mrsteam.com I www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 I 9410 S. La Cienega Blvd.
mr.steam ® Optional Autoflush System ____________________________________________________________________________________________________________________________________________ INSTA LLAT ION INS TRUCTI ONS BOX CONTENTS: • AutoFlush System Valve with Cord • Installation Instructions.
INSTALLATION INSTRUCTIONS 1. Plumbing to be performed by a qualified plumber and shall be in accordance with applicable national and local codes. Unit drains by gravity. A drain line that is lower than the AutoFlush assembly must be available. The AutoFlush System valve outlet is threaded 1/2" NPT. Check plumbing code for receptor, trap and vent requirements. 2.