Generator Installation Sheet

LOCATING THE STEAM GENERATOR
Select a location as near as practical to the steam room.
Typical locations include: closet, vanity cabinet, heated attic or basement.
NOTE:
The standard length of the cable for connecting the control to the steam generator is 30 feet. The steam generator and
control must be located accordingly. A 60 foot cable is available as a special order part for iTempo
®
and AirTempo
®
, PN 103990-
60 and PN 104117-60 for iSteam
®
.
The maximum cable length is 60 feet.
IMPORTANT NOTE: The control cable should be run in a dedicated 1" conduit to facilitate installation and service.
DO NOT route iSteam, AirTempo, iTempo/Plus, iTempo, HomeWizard or iGenie control wiring inside conduit
together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation.
(Items 1-4)
1. DO NOT
install steambath generator inside steam
room, a shock hazard will occur
2. DO NOT
install steambath generator outdoors or
wherever environmental conditions may result in a
shock hazard or affect performance of the generator.
3. To prevent damage to the steam generator or a fire
hazard DO NOT
install steambath generator near
flammable or corrosive materials or chemicals such as
gasoline, paint thinners, or the like. Installation in areas
having high concentrations of chlorine (such as pool
equipment room) must be avoided.
4. Burn Hazard. Steam line, safety valve, drain valve and
plumbing become hot during operation and remain
hot after shutdown for a period of time. Provide
appropriate protection, including insulating plumbing
lines. Avoid plumbing runs and steamhead locations
that can come in contact with bathers.
(Items 5-7)
5. DO NOT
install steambath generator or plumbing lines
in unheated attic or any locations where water could
freeze and cause pipes to rupture and cause property
damage.
6. Install steambath generator on a solid and level
surface. Keyhole slots are provided for wall mounting.
Insure the steam generator is properly secured and level
when mounting with keyhole slots to prevent damage to
the steam generator.
7. Install steambath generator in an upright position only
to prevent damage to the generator.
IMPORTANT NOTES: (Items 8-12)
8. Install anti-water hammer device as necessary.
9
.
Provide a minimum of (12) inches at both ends and top of
the steam generator or as required for servicing. See page 8.
10.
Provide unions as required to facilitate installation
and disconnection of piping.
11
. MrSteam controls can be located inside the steam room
or on the outside of the steam room. See the Control
Installation Manual for your specific control package for
specific details.
12. The MS series of steam generators are for residential
use only. Commercial or other nonresidential applications
void the warranty and may adversely affect product
performance and may represent a safety hazard.
NOTE:
MrSteam Generators (inclusive of the iTempo, AirTempo
and iSteam series Controls) are CE and UL listed.
Suitable for operation in ambient not
exceeding 45 °C (113˚ F)
WATER QUALITY INFORMATION
For optimum results, the water supply should be tested prior
t
o installation. If the mineral content exceeds the following
recommended limits, various external treatment processes
are recommended to correct the problem.
NOTE: An analysis of the on-site water must be made by
a recognized and reliable water treatment company to
ascertain the existing condition and treatment required.
Poor water quality can affect efficiency or result in steam gen-
erator damage. Water contains impurities in solution and sus-
pension. These impurities concentrate in the generator. The
concentration of these impurities increases as more feedwater
is introduced into the generator and steam is produced. If the
suspended solids are allowed to concentrate beyond certain
limits, a deposit or “scale” will form on the generator internal
surfaces. This deposit can interfere with the proper generator
operation and cause generator failure. The concentration of
these impurities is generally controlled by the water quality
and by periodic draining of the generator.
RECOMMENDED FEEDWATER QUALITY
Hardness, ppm 8 85 (~0.5 5 gpg)
P-Alkalinity, ppm 85 410 (~5 24 gpg)
T. Alkalinity, ppm 200 500 (~7 0 gpg)
pH (strength of alkalinity) 8.0 11.4
Every 2 months, or more often in “hard” water areas,
the manual drain valve should be opened fully flushing
out accumulated materials, salts and other particles
which are natural by-products of boiling water.
The optional AutoFlush System feature automatically
drains the MrSteam
®
generator following each use.
A time delay allows the water to cool down (about
two hours) before it drains by gravity for a safe and
gentle operation.
WARNINGS
!
CAUTIONS
!
4
I N S T A L L E R
mr
.
steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
WARNING
!
WARNING
!