Residential Generator Install Manual

2
Materials of construction, room size and special design features such
a
s large glass areas, all affect
t
he steam generator model selection.
1.
Measure length, width & height in feet of the steam/shower or tub/shower
Multiply the Length ____ x Width_____ x Height _____ =
2.
Construction Materials:
For natural stones: natural marble, Add 110%
stone, shale, glass block or concrete
For ceramic or porcelain tile on Add 40%
cement board or mortar bed
3.
Ceiling Height: For each foot above 8 feet Add 15%
4. Add all figures above to obtain the Total Room Volume required
ROOM VOLUME
SELECT YOUR MRSTEAM
Compare your Room Volume to the Chart below
and select the appropriate model.
In considering the purchase or
u
se of this steambath system, please note that if
you are pregnant, have a coronary condition, are
in poor health, are being treated for any other
medical condition, or are using medication or
drugs, MrSteam recommends that you obtain the
approval of a physician before use.
For information about this product and safety
issues, please call 1.800.76.STEAM
IMPORTANT NOTES:
F
or steam rooms constructed of acrylic or
synthetic materials, select next lower-rated
MS model.
The MrSteam Sizing Chart allows for up to 60 feet
of insulated steam line from the MS generator to
the steam room. If the 60 foot line is exceeded
consult with factory. The steam generator control
locations must be taken into account. A 30 foot
cable is standard. Contact MrSteam to purchase
an optional 60 ft. cable PN 103990-60 for
iTempo
®
and AirTempo
®
and PN 104117-60 for
iSteam
®
. The maximum cable length is 60 feet.
R E S I D E N T I A L S T E A M G E N E R AT O R S S P E C I F I C AT I O N C H A R T
Amps (for Wire Total Adj. Water Usage Shipping
Model No. KW 240v/1PH)† Size‡ Room Vol. Gallons†† Dimensions* Wt. (lbs)**
MS90E 5 21 10 100 0.67 14½"L x 14¾"H x 6¾"D 30
MS150E 6 25 8 150 0.80 14½"L x 14¾"H x 6¾"D 30
MS225E 7.5 32 8 225 1.0 14½"L x 14¾"H x 6¾"D 30
MS400E 9 38 8 360 1.2 14½"L x 14¾"H x 6¾"D 30
MS SUPER 1E 10 42 8 475 1.4 17"L x 18½"H x 7
7
8"D 40
MS SUPER 2E 12 50 6 575 1.6 17"L x 18½"H x 7
7
8"D 40
MS SUPER 3E 15 63 4 675 2.0 17"L x 18½"H x 7
7
8"D 40
MS SUPER 4E 20 84 8 875 2.7 17"L x 18½"H x 7
7
8"D x 2 80
MS SUPER 5E 24 100 6 1075 3.2 17"L x 18½"H x 7
7
8"D x 2 80
MS SUPER 6E 30 125 4 1275 4.0 17"L x 18½"H x 7
7
8"D x 2 80
IMPORTANT NOTES:
Add C1 suffix to Model No. for 240V/1Ph; Add B1 suffix to Model No. for 208V/1Ph.
Models SUPER 1E-6E must use iTempo/Plus
®
control.
All MrSteam MS Models are cULus Listed and CE approved.
NOTES:
All MS Generators available in 240v/1PH, 208v/1PH and other voltages/phases.
Amps are for 240/1PH rated units.
‡Wire size (AWG) based on minimum 90˚C rated THHN copper conductors.
Refer to the National Electrical Code for other types of conductors.
See MrSteam® Installation and Operation Manual for complete dimensional and installation information.
MS SUPER 4E includes two MS SUPER 1E steam generators, and require one iTempo/Plus
®
Control, and two matching steamheads. MS SUPER 5E includes two MS SUPER 2E
steam generators, and require one iTempo/Plus
®
Control, and two matching steamheads. MS SUPER 6E includes two MS SUPER 3E steam generators, and require one
iTempo/Plus
®
Control, and two matching steamheads.
*Dimensions are for generator only, without
AutoFlush® or plumbing features.
**Shipping weight and pricing are for generator only,
without control or steamhead.
†† Water usage based on 20 minutes of operation.
mr
.
steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
MrSteam @ Your Fingertips:
Start working smarter with MrSteam’s mobile sizing app,
now available for the iPad
®
, iPod
®
and most smart phones.
Visit mrsteam.com to size your generator automatically
or go directly to: http://isizing.mrsteam.com
WARNING
!