Specification

14
1
/
2
"
(368)
2
1
/
2
"
(64)
5
1
/
8
"(130)
1
3
/
4
"
(45)
6
3
/
4
"
(171)
1
3
/
4
" (45)
5"
(127)
6
3
/
8
"
(162)
1
7
/8"(48)
5
1
/
8
"
(130)
8
1
/
4
"
(210)
14
3
/
4
"
(375)
11
7
/
8
"
(302)
Water Inlet
Control & Acces-
sory Connections
Steam Outlet
Safety Valve
Manual Drain Valve
Optional
AutoFlush
mr
.
steam
®
Sussman-Automatic Corp
®
hello@mrsteam.com www.mrsteam.com
43-20 34th Street, Long Island City, NY 11101 TEL: 800 76 STEAM / 9410 S. La Cienega Blvd. Inglewood CA 90301 TEL:800 72 STEAM
Mr.Steam Standard Features
• Stainless steel tank
• Industrial, large diameter,
serviceable heating element
• Modular Plug and Play connections
• Electronic water-level control system
• Full-port drain valve
• Limited lifetime generator parts warranty
Safety Features
• Built-in, low-voltage 24-volt control
• ASME safety valve
Locating and Installing the Steam Generator Unit
• Select a location as near as practical
to the steam room, within 60 feet.
Typical locations include: closet, van-
ity cabinet, heated attic or basement.
Do not install steambath generator
inside the steam room.
Do not install steambath generator
outdoors or wherever environmental
conditions may affect the safety and/
or performance of the generator.
• Do not install steambath generator or
plumbing lines in unheated attic or
any locations where water could
freeze.
• Do not install steambath generator
near flammable or corrosive materials
Required Plumbing
Steam Outlet (1/2" NPT) Drain (1/2" NPT)
Water Supply (3/8" NPT) Safety Valve (3/4" NPT)
Steam Head (1/2" NPT)
Electrical
All electrical wiring to be installed by a qualified
licensed electrician in accordance with National
Electrical Code and local electrical code.
Power Wiring
1. Check power voltage. Use 240V rated unit when
supply matches rating of unit before installation.
2. Use minimum 90˚ C/300V rated insulated copper
conductors only, type THHN or equal sized in
accordance with National Electrical Code and local
electrical code for the Amps in Ampere Chart.
If allowed by code, NM cable may require a larger
wire size than as listed on the chart.
3. Connect suitably sized equipment grounding wire to
ground terminal provided.
4. Install a separate circuit breaker between supply and
unit. Provide a power supply disconnect within
sight of the steam generator or one that is capable
of being locked in the open position.
A M P E R E C H A R T
Max Room Volts Wire Size
Model no. Vol. cu.ft. KW 1 ph Phase Amps (AWG)
MS90E 100 5
208 1 24 10
240 1 21 10
MS150E 150 6
208 1 29 8
240 1 25 8
MS225E 225 7.5
208 1 36 8
240 1 32 8
MS400E 360 9
208 1 44 8
240 1 38 8
MODEL VOLTAGE* PHASE OPTIONS PROJECT INFORMATION
B=208
1-Single Phase
Express
C=240
3-Three Phase
Steam
*
Contact Mr. Steam for other voltages
Notes:
Location:
Architect:
Engineer:
Contractor:
Submitted By:
Date:
Required Equipment: Required Equipment:
iSteam3, AirTempo, iTempo, iTempoPlus Controls
Optional Equipment: iGenie, AudioWizard, ChromaSteam, HomeWizard, Recessed
Light, MS Light, MS Wallseat, AutoFlush, Condensation Pan, AromaSteam
or chemicals or in areas having a high
concentration of chlorine.
• Install steambath generator on a solid
and level surface or securely mounted to
a wall using the keyhole slots provided.
• Install steambath generator in an upright
position only.
• Provide a minimum of 12 inches inches
at both ends and top of the steam
generator or as required for servicing.
Alternately provide unions to facilitate
installation and disconnection of the
steam generator.
• The minimum clearance from com-
bustible surfaces is zero all around.
FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR
SAFE AND TROUBLE FREE INSTALLATION visit mrsteam.com before
installation to download the Installation, Operation and Maintenance
Manual or refer to the manual provided with the unit.
TS0041-90E-400E REV 2.1.19
mr
.
steam
®
Technical Specifications
______________________________________________________
Model MS90E-400E
Serial Number 900000 and higher
• 60-minute electronic countdown
shutdown with 75-minute limiting
safety back-up
MS90E
MS150E
MS225E
MS400E

Summary of content (4 pages)