Drawings for Illustrative Purposes Only.
The Remote Temperature Probe is required
when the iTempo or TempoPlus Controls are
installed outside the steam room.
The Remote Temperature
Probe (P/N MSTS) is for use with iTempo
and iTempoPlus Controls only. Do not use
with any other controls. Do not use any other
temperature probe with the iTempo and
iTempoPlus controls. Noncompatible prod-
ucts may result in an inoperative control and
a hazardous condition.
Install the iTempo or
iTempoPlus controls according to the
installation instructions on pages 3-5. Failure
to do so may result in an inoperative control
and a hazardous condition.
1. Determine the location of the Remote
Temperature Probe:
The Remote Temperature Probe must
be installed
:
a. On a vertical surface
b. 4-5 feet above the oor
c. in a location representative of the de-
sired steam bathing temperature. Locating
the MSTS near the steamhead or near
direct steam emissions may result in poor
steam room temperature control.
d. The probe has an integral 30’ cable. In-
sure that the probe and/or steam generator
are located accordingly.
2. Drill a 5/16 inch diameter hole in the wall.
Do not oversize or under size the hole.
Clean area thoroughly.
NOTE: The silicone supplied by Mr. Steam can
be used to meet a variety of sealing and
gasketing. It cures to silicone rubber and
adheres to glass, wood, metal, porcelain,
ceramic tile, painted surfaces, many plastics
and rubber. Surfaces must be clean and dry.
Apply thin layer of product. Fit together and
support if necessary. Allow excess material
to cure, then trim with a sharp blade. Sealant
“skins” in 5 minutes, dries to touch in 1 hour.
Fully cures and bonds in 24 hrs.
3. Remove the knock-out from the steam
generator jacket as shown in Diagram 1.
4.
Insert the probe cable through the knock-out
and connect to the connector on the steam
generator printed circuit board marked EXT
TEMP as shown in Diagram 1.
CAUTION
!
CAUTION
!
Installing the Remote Temperature Probe
(PN: MSTS)