AirTempo Installation Manual

mr
.
steam
®
Installation Instructions
________________________________________________________________________________________________
11
Silicone Sealant
Cable
Wall
1
⁄4" minimum
1
2"
maximum
5. Route the end of the probe cable with the temperature probe
through the wall into the steam room as shown in Diagram 2.
IMPORTANT NOTE: Do not strain, staple, pinch or otherwise
damage the probe cable.
6. With a minimal length of the cable exposed apply silicone
(provided) to the hole in the wall as required to create a mois-
ture seal as shown in Diagram 2.
7. Push the temperature cable and probe into hole as required to
leave minimum 1/4”, maximum 1/2” of the bulb exposed as
shown.
WARNING
!
WARNING
!
Sectional View
steam room
interior
Diagram 2
Insure a minimum of 1/4” of the temperature probe is exposed
to the air. Failure to do so may interfere with the ability to sense tempera-
ture and may result in excessive steam room temperatures.
The exposed area of the temperature probe must be free of
silicone or any materials or obstructions that prevent direct exposure to the
steam room air. Failure to do so may interfere with the ability to sense tem-
perature and
may result in excessive steam room temperatures
.
NOTE:
For Illustrative Purposes Only. Drawings Not to Scale
Installed Remote Temperature Probe
showing a minimum of 1/4” of the probe
exposed to steam room air