AirButler/AirButler2 Linear AirTempo Wireless Control Linear SteamHead SteaLinx Mobile App MS / Super AutoFlush MX AutoFlush Condensation Pan PUR100503 PUR100561-1 PUR100518 PUR100200E PUR100532 TS0012 10-16 02-19 01-18 10-15 02-10 02-19 2019-03-14
mr Installation, Operating & Maintenance Instructions .
mr Installation, Operating & Maintenance Instructions .steam ________________________________________________________________________________________________ ® When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTRUCTIONS 2. ! WARNING Do not permit children under the age of 16 to use this steambath. 3.
mr Installation, Operating & Maintenance Instructions .steam ________________________________________________________________________________________________ ® READ ME FIRST! ! WARNING As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and operation of the steambath system.
mr Installation Instructions .steam ________________________________________________________________________________________________ ® Before Installing Carefully inspect the control and packaging for shipping damage. In the event of shipping damage, please contact the carrier for claim information. Our customer service department can assist you with any missing or damaged parts.
mr Installation Instructions .steam ________________________________________________________________________________________________ ® Dimensional Information for the AirTempo 1-5/8” 7/8” Box Contents: • AirTempo Control • Decorative Trim 3-5/8” • Cable (3 ft.
mr Installation Instructions .steam ________________________________________________________________________________________________ ® Installation Instructions for AirTempo Step 1 Determine the desired installation location of the control. The AirTempo controls are designed to be installed inside or outside the steam room as a matter of personal preference. If the control is installed outside the steam room a Remote Temperature Probe part number MSTS must be installed inside the steam room.
mr Installation Instructions .steam ________________________________________________________________________________________________ ® Mounting on Glass When installing AirTempo on glass a peel and stick film is provided on pages 20-21 and may be used as a mask for a clean look from behind the glass. Wireless Receiver Installation The control can be located up to 60 feet from the wireless receiver. Construction materials may affect the communication between the control and the receiver.
mr Installation Instructions .steam ________________________________________________________________________________________________ ® IMPORTANT NOTE: Do not rest the dongle on the steam generator, the metal case of the generator may shield the RF signal. The control features an integral temperature sensor. Locate the control in a location representative of the desired steam bathing temperatures. Do not locate the control above or near the steam head or direct steam emissions.
mr Installation, Operating & Maintenance Instructions .steam ________________________________________________________________________________________________ ® Installing the Remote Temperature Probe (PN: MSTS) ! CAUTION The Remote Temperature Probe is required when the AirTempo control is installed outside the steam room. Failure to install the probe, or failure to install the probe correctly will result in an inoperable control and result in excessive temperatures and a hazardous condition.
mr Installation Instructions .steam ________________________________________________________________________________________________ ® Diagram 1 Temperature Probe Connection Knock-Out Temperature Probe Cable (30 feet) Mr.Steam Steam Generator Temperature Sensor Probe (shown with cover removed and NOT installed) Drawings for Illustrative Purposes Only.
mr Installation Instructions .steam ________________________________________________________________________________________________ ® 5. Route the end of the probe cable with the temperature probe through the wall into the steam room as shown in Diagram 2. important note: Do not strain, staple, pinch or otherwise damage the probe cable. 6. With a minimal length of the cable exposed apply silicone (provided) to the hole in the wall as required to create a moisture seal as shown in Diagram 2. 7.
mr Installation Instructions .steam ________________________________________________________________________________________________ ® AirTempo Operating Instructions The AirTempo features programmable temperature control, programmable time duration, AromaSteam ON/OFF, ChromaSteam® control and two personal settings. The LCD will be OFF until a button is pressed. The LCD remains lit for 10 seconds after the last button is pressed. When the steam generator turns OFF the display will turn on and read OFF.
mr Operating Instructions .steam ________________________________________________________________________________________________ ® Setting the Temperature Diagram 3 Diagram 3: Press TEMP key to set the desired temperature or display the temperature setting. The control is preset and will display a temperature setting of 110˚F (default setting). With the temperature displayed, press the LEFT or RIGHT arrows to set the desired temperature (80°F to 120°F) in one degree increments.
mr Operating Instructions .steam ________________________________________________________________________________________________ ® AromaSteam AROMA The AromaSteam is an optional accessory that automatically injects aromatic oil into the steam. Press the ON/OFF key to turn the steam generator on. Then, press the AROMA key. The Aroma indicator will turn ON. The AromaSteam turns off automatically when the steam generator stops heating. Press the AROMA key to turn it off during a steam session.
mr Operating Instructions .steam ________________________________________________________________________________________________ ® Battery Replacement The batteries in AirTempo will need periodic replacement. Both batteries should be replaced at the same time with new CR2450 coin cell batteries. Batteries ! WARNING CHOKE HAZARD. The batteries and battery doors are small pieces, keep out of reach of children. ! WARNING KEEP BATTERIES OUT OF REACH OF CHILDREN.
mr Maintenance Instructions .steam ________________________________________________________________________________________________ ® System Status Codes The AirTempo may display a status code if the steam system is not functioning correctly. Care Tips for AirTempo Controls and Steamheads CO indicates the AirTempo control has lost communication with the steam generator. Ensure all connections are secure between the steam generator and the transceiver 1.
mr Maintenance Instructions .
mr Maintenance Instructions .steam ________________________________________________________________________________________________ ® (For North American Version) FCC/Industry Canada Two Part Statement: Note: This equipment has been tested and found to comply with the limits This device complies with FCC Part 15 and Industry Canada license exempt RSS standard(s).
mr Maintenance Instructions .
mr Installation Instructions .steam ________________________________________________________________________________________________ ® Flush Mount AirTempo IMPORTANT NOTE: Flush mount components are sold separately (104232RD & 104232SQ). Contact a MrSteam representative if a flush mount kit is needed. • Remove the surface mount bayonet from the back of the AirTempo control. The surface mount bayonet is not used when flush mounting. The surface mount decorative bezel is not used when flush mounting.
www.mrsteam.com Products, information and specifications are subject to change without notice. For more information call Sales & Support at: 1.800.76.STEAM (East Coast) 1.800.72.STEAM (West Coast) mr.steam Sussman-Automatic Corporation hello@mrsteam.com www.mrsteam.com 9410 S. La Cienega Blvd., Inglewood CA 90301 800 727 8326 fax: 310 216 2944 ® 43-20 34th Street, Long island City NY 11101 800 767 8326 fax: 718 472 3256 PN 100503 rev 10.
Linear Steam Head ® mr.steam ® –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Installation Instructions Model 104216 READ ME FIRST! ! As you follow these instructions, you will notice warning and caution symbols. This information is important for the proper, safe and trouble free installation of the Linear Steam Head.
mr.steam Linear Steam Head® ® ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Installation Instructions: Model 104216 R E A D M E F I R S T ! (cont.) ! CAUTION • DO NOT use black iron pipe or galvanized pipe for the steam line. Use brass pipe or copper tubing only, and in accordance with national and local plumbing codes. • Do not modify or alter the steam head.
mr.steam Linear Steam Head® ® ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Installation Instructions: Model 104216 INSTALLATION STEPS STEAM EMISSION ! CAUTION Because steam emissions are very hot, locate the steam head where incidental contact by the bather with direct steam emission cannot occur.
mr.steam Linear Steam Head® ® ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Installation Instructions: Model 104216 STEP 5. Plumb rigid copper tubing or brass pipe from the steam generator to the steam head. Plumbing must not form traps or valleys. Thread sealant must be used as required to ensure a leak free joint. ! CAUTIONS • Plumbing must be installed by a qualified and licensed plumber.
I N S TA L L AT I O N I N S T R U C T I O N S Package Contents: SteamLinx Module and Mobile App allows for seamless control of time and temperature using your smart phone or mobile device. SteamLinx works with all MrSteam controls (for MS generators SN 1174000 and up). • SteamLinx A with Integral Cable • SteamLinx B and Ethernet Cable • Power Supply and Cable • Instructions These instructions contain safety alert symbols and panels.
2 Connecting SteamLinx B to the Home Router Home Router • Plug the blue ethernet cable provided, into an ethernet slot on the back of the home router. Power • Plug the power Supply supply into a 120V outlet. 3’ Cable Ethernet Cable (3’) 3 Connecting SteamLinx to the Internet 4 Troubleshooting: Blinking LED Troubleshooting: Indicator Lights Units are out of range or not paired LEDs • Insure the mobile device is on the WiFi network.
mr.steam ® Optional Autoflush® System ____________________________________________________________________________________________________________________________________________ INSTA LLAT ION INS TRUCTI ONS BOX CONTENTS: • AutoFlush System Valve with Cord • Installation Instructions.
INSTALLATION INSTRUCTIONS 1. Plumbing to be performed by a qualified plumber and shall be in accordance with applicable national and local codes. Unit drains by gravity. A drain line that is lower than the AutoFlush assembly must be available. The AutoFlush System valve outlet is threaded 1/2" NPT. Check plumbing code for receptor, trap and vent requirements. 2.
mr.steam ® Optional AutoFlush® System ____________________________________________________________________________________________________________________________________________ INSTA LLAT ION INS TRUCTI ONS BOX CONTENTS: • AutoFlush System Valve with Cord • Installation Instructions.
INSTALLATION INSTRUCTIONS 1. Plumbing to be performed by a qualified plumber and shall be in accordance with applicable national and local codes. Unit drains by gravity. A drain line that is lower than the AutoFlush assembly must be available. The AutoFlush System valve outlet is threaded 1" NPT. Check plumbing code for receptor, trap and vent requirements. 2.
mr.steam ® Technical Specifications Condensation Pan 103867 & 104402 Mr.Steam strongly recommends the use of a condensation pan in the unlikely event of a plumbing leak. Locate the condensation pan on a solid level surface and place the steam generator inside the condensation pan. Insure the steam generator is level. All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable national and local codes.