Installation Sheet

mr
.
steam
®
Installation Instructions
________________________________________________________________________________________________
66
Installation Instructions for AirTempo
STEP 1
Determine the desired installation location of the control. The AirTempo
controls
are designed to be installed inside or outside the steam room as a matter of
personal preference. If the control is installed outside the steam room a Remote
Temperature Probe part number MSTS must be installed inside the steam room.
IMPORTANT NOTE: See installation instructions for the MSTS Temperature
Probe (pgs. 10-12) before rough-in or installation of control.
If the control is installed inside the steam room the control must be located:
• 4-5 feet above the oor near the bather seating area.
• On a vertical wall
The control features an integral temperature sensor. Locate the control in a
location representative of the desired steam bathing temperatures. Do not
locate the control above or near the steam head or direct steam emissions.
Locating the controls near the steamhead or near direct steam emissions may
result in poor steam room temperature control.
The control can be located up to 60 feet from the wireless receiver.
Construction materials affect the communication between the control and
receiver. Test the range of the AirTempo. It may be necessary to change
the location of the wireless receiver to improve the range.
Contact MrSteam technical service for an optional 30 or 60 foot cable.
STEP 2
The AirTempo control can be surface or ush
mounted according to personal preference.
Flush mount components are sold separately
(104232RD & 104232SQ). Contact a MrSteam
representative if a ush mount kit is needed,
see page 22.
Surface Mount AirTempo
• Remove the surface mount bayonet from
the back of the AirTempo Control.
• Remove & discard the release paper to
expose the adhesive liner.
• Ensure the mounting surface is clean & dry.
• Place the bayonet on the wall in the desired
location.
IMPORTANT NOTE: Use the screw and anchor provided to secure
the bayonet to the wall as required for rough or uneven wall
surfaces. The surface mount bayonet supports the weight of the
AirTempo control.