Installation Sheet

mr
.
steam
®
Installation, Operating & Maintenance Instructions
________________________________________________________________________________________________
9
The Remote Temperature Probe is required when the
AirTempo control is installed outside the steam room. Failure to install the
probe, or failure to install the probe correctly will result in an inoperable
control and result in excessive temperatures and a hazardous condition.
The Remote Temperature Probe is for use with AirTempo,
iTempo and iTempoPlus controls only. Do not use with any other controls.
Do not use any other temperature probe with the AirTempo, iTempo and
iTempoPlus controls. Noncompatible products may result in an inoperative
control and a hazardous condition.
Install the AirTempo controls according to the installation
instructions on pages 6-7. Failure to do so may result in an inoperative
control and a hazardous condition.
1. Determine the location of the Remote Temperature Probe:
The Remote Temperature Probe must be installed:
a. On a vertical surface
b. 4-5 feet above the oor
c. in a location representative of the desired steam bathing temperature.
Locating the MSTS near the steamhead or near direct steam
emissions may result in poor steam room temperature control.
d. The probe has an integral 30’ cable. Insure that the probe and/or
steam generator are located accordingly.
2. Drill a 5/16 inch diameter hole in the wall.
Do not oversize or under size the hole. Clean area thoroughly.
NOTE: The silicone supplied by MrSteam can be used to meet a va-
riety of sealing and gasketing. It cures to silicone rubber and adheres
to glass, wood, metal, porcelain, ceramic tile, painted surfaces, many
plastics and rubber. Surfaces must be clean and dry. Apply thin layer
of product. Fit together and support if necessary. Allow excess mate-
rial to cure, then trim with a sharp blade. Sealant “skins” in 5 minutes,
dries to touch in 1 hour. Fully cures and bonds in 24 hrs.
3. Remove the knock-out from the steam generator jacket as shown in
Diagram 1.
4. Insert the probe cable through the knock-out and connect to the
connector on the steam generator printed circuit board marked EXT
TEMP as shown in Diagram 1.
CAUTION
!
CAUTION
!
CAUTION
!
Installing the Remote Temperature Probe
(PN: MSTS)