Installation, Operation & Maintenance Manual ® ® iTEMPO & iTEMPOPLUS CONTROLS mr.steam ® Feel Good Inc. www.mrsteam.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTRUCTIONS 2. ! WARNING Supervise children at all times. 3. ! WARNING Steam is hot and can cause injury or death if improperly used. Steam rooms contain steam and elevated temperatures. Please read and observe all warnings in this manual before installing or using a steam room. 4.
mr Installation & Operating Instructions .steam _________________________________________________________________ ® REA D ME F IR S T ! Table of Contents: ! WARNING As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and operation of this generator. These are types of potential hazards that may occur during installation and operation: Important Safety Instructions...............................
mr Installation & Operating Instructions .steam _________________________________________________________________ ® BEFORE INSTALLING Carefully inspect the control and packaging for shipping MrSteam technical service 1-800-767- 8326 for damage. In the event of shipping damage, please contact more information on the Remote Temperature the carrier for claim information. Our customer service de- Probe. partment can assist you with any missing or damaged parts.
mr Installation & Operating Instructions .steam _________________________________________________________________ ® Dimensional Information for the Round and Square iTempo and iTempoPlus ® ® 41/2” 1” 3/8” 21/2” 5” 1/4” Box Contents: • iTempo or iTempoPlus Control • Control Cable (30 ft.) • Steam head • Tube of Silicone sealant • Owner’s Manual 5” 3/ ” 33/ ” 4 4 12” long pigtail 5 Drawings for Illustrative Purposes Only.
mr Installation & Operating Instructions .steam _________________________________________________________________ ® Installation Instructions for Round & Square iTempo® and iTempoPlus® IMPORTANT NOTE: If the desired location for the control is outside the steam room a Remote Temperature Probe (MSTS) must be installed inside the steam room. Contact MrSteam technical service 1-800-7678326 for more information on the Remote Temperature Probe. NOTE: The connector is keyed with the flat facing up.
mr Installation & Operating Instructions .steam _________________________________________________________________ ® Step 2 Diagram 1 Make a 2-5⁄8” wide by 3-7⁄8” high cutout in the desired control location. Do not oversize or under size the cutout. tep 3 Diagram 2 S Route the control cable (provided with the control) from the wall cutout to the steam generator. Connect one end of the cable to the steam generator connector. Diagram 2 NOTE: The connector is keyed with the flat facing up.
mr Installation & Operating Instructions .steam _________________________________________________________________ ® Step 5 Diagram 4 Remove and discard peel-off paper to expose adhesive liner. Diagram 5 Step 6 Diagram 5 Run a bead of silicone (provided) as shown to the outer edge of the control faceplate, following the contour of the circle or square shape. Use silicone as required to create a moisture seal. Note: The silicone supplied by MrSteam can be used to meet a variety of sealing and gasketing.
mr Installation & Operating Instructions .steam _________________________________________________________________ ® iTempo® Operating Instructions The iTempo Control features programmable digital temperature control, a fixed (60) minute duration, ON/OFF and PAUSE.
mr Installation & Operating Instructions .steam _________________________________________________________________ ® Timer Feature When the control is turned ON a 60 minute time duration is initiated. The control will turn off after 60 minutes unless the control is turned off manually. Memory Feature If the control is turned off manually before 60 minutes then the default temperature of 110˚F will be used the next time the control is turned on.
mr Installation & Operating Instructions .steam _________________________________________________________________ ® iTempoPlus® Operating Instructions The iTempoPlus Control features programmable temperature control, programmable time duration, clock, AromaSteam, ChromaSteam®, ON/OFF and two personal settings.
mr Installation & Operating Instructions .steam _________________________________________________________________ ® Setting the Clock Diagram 3 When the display is not flashing: Press and hold the TIME key until the display starts flashing. Use the UP/DOWN keys to select the desired time, at this time the AM/PM logo will be displayed. Press the TIME key to save changes. Setting the steambath Duration Diagram 4 Press TIME key to set or display the steambath duration time on the clock.
mr Installation & Operating Instructions .steam _________________________________________________________________ ® Setting the Temperature Diagram 6: Press TEMP key to set the desired temperature or display the temperature setting. Diagram 7: The control is preset and will display a temperature setting of 110˚F (default setting). With the temperature displayed, press the UP or DOWN keys to set the desired temperature (80°F to 120°F) in one degree increments.
mr Installation & Operating Instructions .steam _________________________________________________________________ ® Changing the Temperature units (˚F/˚C) When the generator is Off, Press and hold ON/OFF key for 10 seconds. The temperature units will be displayed as Fahrenheit (TuF) or Celsius (TuC). Use the UP/DOWN keys to choose between (TuF) and (TuC). Press ON/OFF key to accept the new value and exit. aroma mr.
mr Installation & Operating Instructions .steam _________________________________________________________________ ® Display mr.steam Up Key Time Display/ Adjust Key ON/OFF Key temp time aroma chroma AromaSteam Key Time Display/ Adjust Key Down Key Program Key ChromaSteam Key Care Tips for all Controls and Steamheads 1. Use only mild soap and water on a soft cloth to clean the control and steamhead. 2. Do not use abrasive cleansers 3.
mr.steam ® Feel Good Inc. Products, information and specifications are subject to change without notice. For more information call Sales & Support at: 1.800.76.STEAM (East Coast) 1.800.72.STEAM (West Coast) 2019 © Sussman-Automatic Corporation MrSteam and des., AromaFlo, AutoFlush, AutoSteam, Butler Package, ChromaSteam, Clean Steam...
mr.steam ® STEAM HEAD ___________________________________________________________________________________________________________________________________________ I N S TA L L AT I O N I N S T R U C T I O N S 1/8" minimum clearance required when Acrylic Shield is used. See installation instructions provided with the Acrylic Shield.
Installation, Operation and Maintenance Manual Linear Steam Head Residential Model: 144080 ____________________ MPORTANT: Leave this material with t he homeowner. _IMPORTANT: _____ _Leave _ _this _ _material _ _ _with _ _the_homeowner. __ mr.steam ® Feel Good Inc.
Linear Steam Head ® ® Installation Section – Read Me First & Cautions READ ME FIRST! Model 104480 As you follow these instructions, you will notice CAUTION and IMPORTANT NOTE symbols. This information is important for the proper, safe and trouble free installation of the Linear Steam Head. These are types of potential hazards that may occur if in-stallation instructions are not carefully followed. This signals a situation where injury or property damage may occur if you do not follow instructions.
Linear Steam Head ® ® Installation Section – Read Me First & Cautions • Steambath controls feature an integral temperature sensor. Locate the Steam Head in a location where steam emissions will not come in direct contact with the control (or the remote temperature sensor). Failure to follow these instructions may result in a hazardous condition, scalding or personal injury. • Use the supplied high temperature silicone sealant as required to create a permanent moisture seal.
Linear Steam Head ® ® Installation Section BOX CONTENTS: • Linear Steam Head • Faceplate • Diverter Model 104480 • AromaTray • Silicone Sealant • Installation Instructions Figure 1 NPT Steam Outlet Connection 3/4” 1111/16” 16" Slotted Slotted Mounting Mounting Holes Holes Adjustment Screws 1 9 1/4” 9 4" Steam Outlet 5 8 5/8”" 1 221/8” 8" Slotted 14 1/16” Mounting Holes Slotted Mounting Holes x 19” 14" INSTALLATION STEPS Generator Model Because steam emissions are very hot, locate the ste
Linear Steam Head ® ® Installation Section Model 104480 INSTALLATION STEPS Copper Tubing or Brass Pipe (Not Provided) STEP 2. Confirm proper stud spacing: The studs must have a minimum spacing of 14-1/16” and a maximum spacing 19". If the stud spacing is outside the required range then shim or otherwise reposition the studs as required.
Linear Steam Head ® ® Installation Section – Installing the Linear Steam Head Steps Model 104480 Faceplate CAU TION INSTALLER: Because the steam head, faceplate and direct steam emission are very hot, locate the steam head and faceplate where incidental contact by bather with the steam head, faceplate or direct steam emission cannot occur.
Linear Steam Head ® Installation Section ® Model 104480 STEAM EMISSION ZONES W AND W/O THE DIVERTER • Plumbing must be installed by a qualified and licensed plumber. Plumb with rigid copper tubing or brass pipe from the generator to the steam head. Plumbing must not form valleys or traps. The formation of a valley or trap may cause the accumulation of condensate resulting poor steam generation operation.
Linear Steam Head ® ® Installation Section – Installing the Linear Steam Head Steps Model 104480 Diverter CAUTION Because direct steam emission is very hot, Diverter will become hot during steam session, and will remain hot for a period of time after steam session. Tile Tile Diverter The Linear steam head is supplied with an optional diverter. The diverter reduces the steam emission zone. Always use the Tile diverter if any steam bather may come into contact with direct steam emissions.
Linear Steam Head ® ® Installation Section – Installing the Linear Steam Head Steps Model 104480 AromaTray ! CAUTION: The AromaTray will become hot during a steam bath session, and will remain hot for a period of time after the steam bath session. Never touch the AromaTray during a steam bath session or for a period of time after the steam bath session. Touching the AromaTray during a steam bath session or for a period of time after the steam bath session may result in personal injury.
Linear Steam Head ® ® Installr Section Model 104480 P104481 - Linear Steam Head, SteamHead only 104483 - LSH Faceplate 104484 - Diverter for Linear SteamHead 104482 - AromaTray for Linear SteamHead 104483BB 104483BN 104483MB 104483ORB 104483PB 104483PC 104483PN 104483SB LSH Faceplate Brush Bronze LSH FaceplateBrush Nickel LSH Faceplate Matte Black LSH Faceplate Oil Rubbed Bronze LSH Faceplate Polish Brass LSH Faceplate Polish Chrome LSH Faceplate Polish Nickel LSH Faceplate Satin For Installation ass
Linear Steam Head ® ® IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS Model 104480 FLAMMABLE LIQUID AND VAPOR • Keep the AromaSteam and fragrance away from heat, sparks, electrical outlets, open flames such as candles and hot surfaces. • No smoking. • Keep Out of the Reach of Children.measures against static discharge. • Contains denatured ethyl alcohol. • In case of fire: Use CO2, dry chemical, alcohol foam, and water spray for extinction.
mr.steam ® Feel Good Inc. ® www.mrsteam.com Products, information and specifications are subject to change without notice. Please call Technical Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information. The model and serial number is printed on the data plate on the front of the steam bath generator. Have this information available when contacting Technical Service. mr.steam ® Sussman-Automatic Corporation® I hello@mrsteam.com I www.mrsteam.
mr.steam ® Optional AutoFlush® System ____________________________________________________________________________________________________________________________________________ INSTA LLAT ION INS TRUCTI ONS BOX CONTENTS: • AutoFlush System Valve with Cord • Installation Instructions.
INSTALLATION INSTRUCTIONS 1. Plumbing to be performed by a qualified plumber and shall be in accordance with applicable National and Local codes. Unit drains by gravity. A drain line that is lower than the AutoFlush assembly must be available. The AutoFlush System valve outlet is threaded 1/2" NPT. Check plumbing code for receptor, trap and vent requirements. 2.
INSTALLATION INSTRUCTIONS 1. Plumbing to be performed by a qualified plumber and shall be in accordance with applicable national and local codes. Unit drains by gravity. A drain line that is lower than the AutoFlush assembly must be available. The AutoFlush System valve outlet is threaded 1" NPT. Check plumbing code for receptor, trap and vent requirements. 2.
mr.steam ® Technical Specifications Condensation Pan 103867 & 104402 Mr.Steam strongly recommends the use of a condensation pan in the unlikely event of a plumbing leak. Locate the condensation pan on a solid level surface and place the steam generator inside the condensation pan. Insure the steam generator is level. All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable national and local codes.