Specification Sheet

INSTALLATION STEPS
Because steam emissions are very hot,
locate the steam head where incidental contact by
the bather with direct steam emission cannot occur.
Do not locate the steam head in any location where
the steam emission zone is near a seat, bench or any
space occupied by any persons. See Fig. 2 for a
diagram of the steam emission zone. Failure to follow
these instructions may result in a hazardous condition,
scalding or personal injury.
Do not install a Linear Steam Head in a
tub or acrylic/fiberglass shower enclosure. Failure to
follow these instructions may result in a hazardous
condition, scalding or personal injury
STEP 1.
Locate the steam head 6-12” above the
finished floor. Do not locate the steam head in any
location where the steam emission zone is near a seat,
bench, or any space occupied by any persons. See
Fig. 2 for a diagram of the steam emission zone.
STEP 2.
Confirm proper stud spacing: The studs must
have a minimum spacing of 14-1/8” and a maximum
spacing 14-1/2 “. If the stud spacing is outside the
required range then shim or otherwise reposition the
studs as required.
Installing the steam head between
incorrectly spaced studs may result in damage to the
steam head and result in a leak within the wall cavity
and cause property damage.
STEP
3. Determine the location of the finished wall
surface. Mount the steam head between two studs
using the four slotted holes to position the steam
outlet face to be flush or extend 1/8” from the
finished wall surface (see Fig. 4).
Failure to position the steam head face
to be flush or extended 1/8” from the finished wall
surface may result in a leak within the wall cavity and
cause problems associated with leaks, moisture and
property damage from leaks.
STEP
4. Use a level to ensure the steam head is level
(see Fig. 3 ) and the steam head face is flush or
extends 1/8” from the finished wall surface. Install the
four screws in the mounting holes to secure the steam
head to the studs.
Linear Steam Head
®
Installation Instructions: Model 104216
mr
.
steam
®
3
NOTE:
Drawings are for illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction.
Copper Tubing
or Brass Pipe
(not provided)
Steam Outlet
Threaded
Adaptor or
Thread Plug
as required
(not provided)
Stud
Stud
Level
14
1
/
8
14
1
/
2
Figure 3
CAUTION
!
CAUTION
!
Steam
head
6”-12”
above
floor
STEA M
EMIS SION
ZONE
Steam Room
Interior
STEA M
EMIS SION
Figure 2
CAUTION
!
CAUTION
!