AUTOFLUSH
7
OPERATION
The optional AutoFlush System feature automatically drains the Mr.Steam
®
system following each
use. A time delay allows the water to cool down (about two hours) before it drains by gravity for
a safe and gentle operation.
NOTE: If the Express Steam option has been installed, the AutoFlush will drain for ten minutes
then refill with fresh water to begin the pre-heat cycle.
!
CAUTION
PROVIDE DRAIN PLUMBING ACCORDING TO LOCAL
CODES. PLUMB AS REQUIRED FOR AUTOFLUSH SYSTEM.
AutoFlush Shown
Fully Assembled
DRAIN VALVE
(shown in open position)
DO NOT REMOVE
DRAIN VALVE
COPPER OR BRASS
NIPPLE
1/2” x3 1/2” or longer
(not supplied)
Arrow indicates
correct direction
of ow
Plum to
drain line
STEAM
GENERATOR
INSTALLATION INSTRUCTIONS
1. Plumbing to be performed by a qualified plumber and shall
be in accordance with applicable national and local codes. Unit
drains by gravity. A drain line that is lower than the
AutoFlush assembly must be available. The AutoFlush System
valve outlet is 1/2” NPT. Check plumbing code for
receptor, trap and vent requirements.
2. Use copper or brass nipple 1/2” NPT x 3 1/2”or longer
(not supplied) to connect AutoFlush valve to the
Drain Valve. An arrow on the bottom of the
AutoFlush indicates the direction of flow.
• 1/2” Copper or Brass union needed
after Autoflush.
OPTIONAL AUTOFLUSH
IMPORTANT The information in this guideline is designed to provide a general overview of how MrSteam products are installed. The diagrams are for Illustrative purposes only. NEVER use this document for the Installation,
Operation or Maintenance of any MrSteam product. For Installation, Operation and Maintenance information, only use the specic Installation, Operation and Maintenance manual supplied with each Mr. Steam product. The
specic Installation, Operation and Maintenance manual that is supplied with each Mr. Steam product contains important information required for the safe and reliable installation and operation of the product. Failure to use
the specic Installation, Operation and Maintenance manual that is supplied with each Mr. Steam product may result in product damage, property damage, death or personal injury. If you do not have an Installation, Operation
and Maintenance manual please contact MrSteam for a free copy, or download a copy from www.mrsteam.com. If you have any questions about the installation, operation or maintenance of any MrSteam product please
contact a customer or technical service representative using the contact information on the back cover of this guideline.