Owners Manual

Product Dimensions* Model No.
Total
Room
Volume
(cu.ft.)
kW
Amps
240V/1PH
Wire
Size
AWG‡
Water
Usage
Gallons
††
MS Generators
14 1/2” x 14 3/4” x 6 3/4” ″
MS90E up to 100 5 21 10 0.67
MS150 101-150 6 25 8 0.80
MS225E 151-225 7.5 32 8 1.0
MS400E 226-360 9 38 8 1.2
SUPER Generators
17” x 18 1/2” x 7 7/8”
MSSUPER1E 361-475 10 42 8 1.4
MSSUPER2E 476-575 12 50 6 1.6
MSSUPER3E 576-675 15 63 4 2.0
MAX Generators
27 5/8” x 20 3/4” x 7 7/8”
MX4E 676-875 20 84 2 2.7
MX5E 876-1075 24 100 1 3.2
MX6E 1076-1275 30 125 2/0 4.0
FOR ADDITIONAL INFORMATION ON
CONTROLS AND ACCESSORIES SEE
CORRESPONDING QUICK GUIDES
* Dimensions are for generator only, without AutoFlush® or plumbing features.
‡ Wire size (AWG) based on minimum 90 rated THHN copper conductors. Refer to the National Electrical Code for other types of conductors.
†† Water usage based on 20 minutes of operation.
WARNING The information in this guide is designed to provide a general overview of how MrSteam® products are installed. All images and diagrams are for illustrative purposes only
and may have been altered for presentation purposes. NEVER use this document for the Installation, Operation or Maintenance of any MrSteam® product. For installation, operation and
maintenance information and instructions, only use the applicable MrSteam® Installation, Operation & Maintenance Manual(s). The specific Installation, Operation & Maintenance manual
that is supplied with each MrSteam® product contains important information required for the safe and reliable installation and operation of the product. Failure to install any MrSteam®
product according to the applicable manual may result in property damage or an inoperable or hazardous condition. If you do not have the applicable Installation, Operation & Maintenance
manual please contact MrSteam® for a free copy, or download a copy from www.mrsteam.com. If you have any questions about the installation, operation or maintenance of any MrSteam®
product please contact a customer or technical service representative using the contact information on the back cover of this guide or consult a properly licensed contractor, architect and/
or design professional.
NEW
12
MRSTEAM
®
GUIDE