REMOTE TEMPERATURE
SENSOR (MSTS)
A Remote Temperature Sensor
is required when the control is
installed outside the steam room.
Locate the RemoteTemperature
Sensor where it will sense
general room temperature and
NOT direct steam emission
from the steam head. Refer
to the MrSteam Installation
manual for additional control
installation information.
For Illustrative purposes only. Consult with
qualified designer, architect or contractor for
steamroom construction details.
INSTALLING A REMOTE TEMPERATURE PROBE
STEP 1
The Probe must be installed:
A. On a vertical surface
B. 4-5 feet above the Floor
C. In a location representative of the desired
steambathing temperatures. Do not locate the probe
above or near the steam head or direct steam emissions.
The probe has an integral 30 or 60 ft. cable. Ensure that
the probe and control are located accordingly.
STEP 2
Drill a 5/16 inch hole in the wall. Do not oversize or
undersize the hole. Clean area thoroughly.
STEP 3
Route the end of the temperature probe cable with the
temperature probe through a conduit inside the wall
cavity as shown in Fig 1.
WARNING The information in this guide is designed to provide a general overview of how MrSteam® products are installed. All images and diagrams are for illustrative purposes only
and may have been altered for presentation purposes. NEVER use this document for the Installation, Operation or Maintenance of any MrSteam® product. For installation, operation and
maintenance information and instructions, only use the applicable MrSteam® Installation, Operation & Maintenance Manual(s). The specific Installation, Operation & Maintenance manual
that is supplied with each MrSteam® product contains important information required for the safe and reliable installation and operation of the product. Failure to install any MrSteam®
product according to the applicable manual may result in property damage, an inoperable system/control, or hazardous condition. If you do not have the applicable Installation, Operation
& Maintenance manual please contact MrSteam® for a free copy, or download a copy from www.mrsteam.com. If you have any questions about the installation, operation or maintenance of
any MrSteam® product please contact a customer or technical service representative using the contact information on the back cover of this guide or consult a properly licensed contractor,
architect and/or design professional.
FIG 1
CABLE
SILICONE
SEALANT
FINISH WALL
1/4”Min
1/2”Max