iButler/iButler2/iButlerX Linear iSteam3 Control Linear SteamHead SteaLinx Mobile App MS / Super AutoFlush MX AutoFlush Condensation Pan PUR100514 PUR100561-1 PUR100518 PUR100200E PUR100532 TS0012 07-17 02-19 01-18 10-15 02-19 02-19 2019-03-14
Installation, Operation & Maintenance Manual iSteam 3 Control ® mr.steam ® Feel Good Inc.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: READ ME FIRST! ! WARNING As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and eff icient installation and operation of this generator.
Table of Contents: Important Safety Instructions......................... 2 Box Contents: INSTALLER INFORMATION • iSteam®3 Control Installation Template .................................... 2 • Control Cable (30 ft.) Box Content.................................................. 3 • Steamhead Dimensional Information............................... 3 • Tube of Silicone Sealant Before Installing............................................. 4 • Owner’s Manual Locating the Control....................
mr INSTALLER INFORMATION .steam __________________________________________________________________ ® Before Installing ! WARNING To avoid unintentional steambath op- ! CAUTION Do not route iSteam3 control wiring inside conduit together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation. Do not alter or modify any Mr. Steam products including the steam generator or iSteam3 control.
mr INSTALLER INFORMATION .steam __________________________________________________________________ ® Locating the Control 1b Determine the desired installation location of the control. The iSteam®3 controls are designed to be installed inside or outside the steam room as a matter of personal preference. If the control is installed inside the steam room: • Locate the control 4-5 feet above the floor near the bather seating area. • The control features an integral temperature sensor.
6b mr INSTALLER INFORMATION .steam __________________________________________________________________ ® Installation with Optional Rough-In Box 6a (cont.) IMPORTANT NOTE: Be careful not to strain, staple, pinch or otherwise damage the cables. Route cables as required to permit replacement. Do not route cables inside conduit together with power lines or close to hot water or steam piping. 7 Step 6 Rough-In box used as a guide to cut out the opening.
mr INSTALLER INFORMATION .steam __________________________________________________________________ ® Installation Instructions for iSteam®3 STEP 1 PLUG the 30’ control cable into the iSteam3 control pigtail (1a). Turn the generator on and test the control to verify correct connection. With proper function, proceed to Step 2. ! CAUTION Do not force or twist cable ends together. Forcing or twisting cable ends may damage the connectors.
mr INSTALLER INFORMATION .steam __________________________________________________________________ ® Installation Instructions for iSteam®3 (cont.) Step 2 2a Peel the double stick adhesive off the back of the iSteam3 control (2a). Apply a bead of silicone around the rear of the iSteam3 control to create a moisture seal (2b). Carefully feed the cables into the rough-in box and secure the control to the wall. Care must be taken to not pinch the cables. Ensure the control is level.
mr.steam H O M E O W N E R ® When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: READ ME FIRST! ! WARNING As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and eff icient installation and operation of this generator.
mr USER/HOMEOWNER INFORMATION .steam __________________________________________________________________ ® Operating Instructions ! WARNING Set the steam bathing duration and temperature according to personal preference, however it is highly recommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels. Set the duration at 10 minutes max. to gauge comfort and safety levels. This will allow the steam generator to heat up and begin producing steam.
mr USER/HOMEOWNER INFORMATION .steam __________________________________________________________________ ® Set Temperature Screen 101 F 12:16 PM 97 Press the TEMPERATURE button on the Dashboard to access the SET TEMPERATURE screen. The control is preset and will display a temperature setting of 110° F (default setting). Swipe your finger up and down to adjust the desired temperature (80 ̊ - 120 ̊ F) in one degree increments.
mr USER/HOMEOWNER INFORMATION .steam __________________________________________________________________ ® AudioSteam 97 Press the music icon to access the AudioSteam screen. Press the MUSIC button to turn on AudioSteam. When AudioSteam is ON, pressing the MUSIC button will turn it OFF. Press the AudioSteam Dashboard button to control the music. When paired to a Bluetooth® device, iSteam®3 will display the song title, artist and album name. If listening to the FM radio, the station number will be shown.
mr USER/HOMEOWNER INFORMATION .steam __________________________________________________________________ ® 97 Settings Screen F 12:16 PM System Settings The Setting Screen allows access to less frequently used screens. Date & Time AutoStart Passcode About System Setting 97 Scroll through the System Settings list and select which to adjust. F 12:16 PM Temperature Units Flip Screen Temperature Units. Adjust between ˚F and ˚C System Setting User Interface Color Flip Screen.
mr USER/HOMEOWNER INSTALLER INFORMATION .steam __________________________________________________________________ ® AutoStart Turn AutoStart ON or OFF ! WARNING AutoStart will automatically turn the steam generator on at your preset time. Activating the steam in an occupied room may subject persons to the hazards described in this manual. Only activate the steambath if the steam room door is closed.
mr USER/HOMEOWNER INFORMATION .steam __________________________________________________________________ ® Care Tips Use only mild soap and water on a soft cloth to clean the control. Do not use abrasive cleansers. Safety and Operating Information ! WARNING A peel and stick warning sticker is provided in the MrSteam steam generator Installation, Operation and Maintenance Manual. This manual is provided with every steam generator.
mr.steam ® Feel Good Inc. ® www.mrsteam.com Products, information and specifications are subject to change without notice. For more information call Sales & Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information. mr.steam Sussman-Automatic Corporation ® ® I hello@mrsteam.com I www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 I 9410 S. La Cienega Blvd.
Linear Steam Head ® mr.steam ® –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Installation Instructions Model 104216 READ ME FIRST! ! As you follow these instructions, you will notice warning and caution symbols. This information is important for the proper, safe and trouble free installation of the Linear Steam Head.
mr.steam Linear Steam Head® ® ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Installation Instructions: Model 104216 R E A D M E F I R S T ! (cont.) ! CAUTION • DO NOT use black iron pipe or galvanized pipe for the steam line. Use brass pipe or copper tubing only, and in accordance with national and local plumbing codes. • Do not modify or alter the steam head.
mr.steam Linear Steam Head® ® ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Installation Instructions: Model 104216 INSTALLATION STEPS STEAM EMISSION ! CAUTION Because steam emissions are very hot, locate the steam head where incidental contact by the bather with direct steam emission cannot occur.
mr.steam Linear Steam Head® ® ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Installation Instructions: Model 104216 STEP 5. Plumb rigid copper tubing or brass pipe from the steam generator to the steam head. Plumbing must not form traps or valleys. Thread sealant must be used as required to ensure a leak free joint. ! CAUTIONS • Plumbing must be installed by a qualified and licensed plumber.
I N S TA L L AT I O N I N S T R U C T I O N S Package Contents: SteamLinx Module and Mobile App allows for seamless control of time and temperature using your smart phone or mobile device. SteamLinx works with all MrSteam controls (for MS generators SN 1174000 and up). • SteamLinx A with Integral Cable • SteamLinx B and Ethernet Cable • Power Supply and Cable • Instructions These instructions contain safety alert symbols and panels.
2 Connecting SteamLinx B to the Home Router Home Router • Plug the blue ethernet cable provided, into an ethernet slot on the back of the home router. Power • Plug the power Supply supply into a 120V outlet. 3’ Cable Ethernet Cable (3’) 3 Connecting SteamLinx to the Internet 4 Troubleshooting: Blinking LED Troubleshooting: Indicator Lights Units are out of range or not paired LEDs • Insure the mobile device is on the WiFi network.
mr.steam ® Optional Autoflush® System ____________________________________________________________________________________________________________________________________________ INSTA LLAT ION INS TRUCTI ONS BOX CONTENTS: • AutoFlush System Valve with Cord • Installation Instructions.
INSTALLATION INSTRUCTIONS 1. Plumbing to be performed by a qualified plumber and shall be in accordance with applicable national and local codes. Unit drains by gravity. A drain line that is lower than the AutoFlush assembly must be available. The AutoFlush System valve outlet is threaded 1/2" NPT. Check plumbing code for receptor, trap and vent requirements. 2.
mr.steam ® Optional AutoFlush® System ____________________________________________________________________________________________________________________________________________ INSTA LLAT ION INS TRUCTI ONS BOX CONTENTS: • AutoFlush System Valve with Cord • Installation Instructions.
INSTALLATION INSTRUCTIONS 1. Plumbing to be performed by a qualified plumber and shall be in accordance with applicable national and local codes. Unit drains by gravity. A drain line that is lower than the AutoFlush assembly must be available. The AutoFlush System valve outlet is threaded 1" NPT. Check plumbing code for receptor, trap and vent requirements. 2.
mr.steam ® Technical Specifications Condensation Pan 103867 & 104402 Mr.Steam strongly recommends the use of a condensation pan in the unlikely event of a plumbing leak. Locate the condensation pan on a solid level surface and place the steam generator inside the condensation pan. Insure the steam generator is level. All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable national and local codes.