Pump fragrance delivery too much
or too little
The AromaSteam system has been factory
set to deliver a suitable amount of aromatic fragrance
into a typical sized steam room. Please contact the
MrSteam Technical Service Department before chang-
ing this setting. See page 12 for instructions on adjust-
ing the amount of fragrance delivery.
Contact the MrSteam Technical Service Dept. at (800)
76-STEAM (East coast) or (800) 72-STEAM (West Coast)
for assistance or additional information.
ELECTRICAL SHOCK HAZARD. MrSteam
AromaSteam pumps are connected to 120V line voltage and
contain live electrical components. All installation and service
to be performed by qualified and licensed electricians and
plumbers only. Installation or service by unqualified persons or
failure to use MrSteam parts may result in property damage or
in a hazardous condition.
TROUBLESHOOTING
-

Pump does not prime
1. Check if voltage is available.
2. Check liquid level in fragrance container.
Replenish liquid, if necessary.
3. Check for air bubbles in the suction tube or
the pump head. To eliminate air bubbles see:
Priming Pump.
4. Check valves for contamination. Clean valves
if necessary.
5. Check foot valve in container for contamination.
Rinse foot valve under clean water.
Pump does not inject fragrance into
steam room
1. Check if voltage is available.
2. Check liquid level in fragrance container. Replenish
fragrance if necessary.
3. Check for air bubbles in the suction tube or the
pump head. To eliminate air bubbles see:
Priming Pump.
4. Check valves for contamination. Clean valves if
necessary.
5. Check foot valve in container for contamination.
Rinse foot valve under clean water.
6. Check the pressure tube for kinking or jamming.
Straighten or replace.
7. Check if fragrance is freely flowing through the
Check Valve when the metering pump is energized.
Apply compressed air through the Check Valve.
Attach the compressed air at the point of connection
of the pressure hose.
8.
Ensure the pump has been powered up. See page 12.