Installation, Operation & Maintenance Manual ® iSteam 2.0 Control mr.steam ® Feel Good Inc.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: READ ME FIRST! ! WARNING As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and eff icient installation and operation of this generator.
Table of Contents: Box Contents: Important Safety Instructions......................... 2 • iSteam 2.0® Control Installation Template .................................... 2 • Control Cable (30 ft.) Box Content.................................................. 3 • Steamhead Dimensional Information............................... 3 • Tube of Silicone Sealant Before Installing............................................. 4 • Owner’s Manual Locating the Control.....................................
mr Controls .steam __________________________________________________________________ ® Before Installing ! ! WARNING To avoid unintentional steambath op- Do not route iSteam 2.0 control wiring inside conduit together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation. Do not alter or modify any Mr. Steam products including the steam generator or iSteam 2.0 control.
mr Controls .steam __________________________________________________________________ ® Locating the Control 1b Determine the desired installation location of the control. The iSteam 2.0 controls are designed to be installed inside or outside the steam room as a matter of personal preference. If the control is installed inside the steam room: • Locate the control 4-5 feet above the floor near the bather seating area. • The control features an integral temperature sensor.
mr Controls .steam __________________________________________________________________ ® Installation with Optional Rough-In Box (cont.) IMPORTANT NOTE: Be careful not to strain, staple, pinch or otherwise damage the cables. Route cables as required to permit replacement. Do not route cables inside conduit together with power lines or close to hot water or steam piping. 6b Step 6 When used, route the AudioWizard™ Cable (6a) through a second knockout in the rough-in box and clip (6b).
mr Controls .steam __________________________________________________________________ ® Installation Instructions for iSteam 2.0® Step 1 PLUG the 30’ control cable into the iSteam 2.0 control pigtail (1a). The iSteam 2.0 pigtail is the longer cable with the ID Tag. If the optional AudioWizard™ is used, remove the Red Cap from the AudioWizard pigtail (1b) and plug it into the AudioWizard cable.
mr Controls .steam __________________________________________________________________ ® Installation Instructions for iSteam 2.0® (cont.) Step 2 2a Peel the double stick adhesive off the back of the iSteam 2.0 control (2a). Apply a bead of silicone around the rear of the iSteam 2.0 control to create a moisture seal (2b). Carefully feed the cables into the rough-in box and secure the control to the wall. Care must be taken to not pinch the cables. Ensure the control is level. IMPORTANT NOTE: The iSteam 2.
mr Controls .steam __________________________________________________________________ ® Operating Instructions ! WARNING Set the steam bathing duration and tem- perature according to personal preference, however it is highly recommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels. Set the duration at 10 minutes max. to gauge comfort and safety levels. This will allow the steam generator to heat up and begin producing steam.
mr Controls .steam __________________________________________________________________ ® Set Temperature Screen Press the TEMPERATURE button on the Dashboard to access the SET TEMPERATURE screen. The control is preset and will display a temperature setting of 110° F (default setting). Swipe your finger from left to right to adjust the desired temperature (80 ̊ - 120 ̊ F) in one degree increments. Press CANCEL to return to the Dashboard without changing the time.
CANCEL HOME F SAVE C mr Controls .steam __________________________________________________________________ ® ˚F / ˚C TOGGLE TEMP F Optional Accessories Screen C 8:19 AM Press the ACCESSORIES button on the START screen to access the optional ChromaSteam® and AudioWizard™ accessories when a steambath is not in session. See page 10 for information on the ChromaSteam and AudioWizard operation.
mr Controls .steam __________________________________________________________________ ® Settings > Passcode The Passcode feature can help prevent unintentional use of the steambath. Please refer to the steam generator Installation, Operation and Maintenance manual (PN 100472) before using the steam bath. The Passcode feature cannot insure unintentional use of the steambath. Enter a 4 digit passcode using the keypad. Press the passcode lock button ON under the 4 digit code to turn the passcode lock on.
mr Controls .steam __________________________________________________________________ ® iSteam 2.0 App IMPORTANT NOTE: Only one smart device can control iSteam 2.0 at a time. To use more devices the App must be closed on all other device. To use iSteam 2.0 from another device, simply press search for iSteam 2.0 after the iSteam 2.0 has been configured. Configuring the iSteam 2.0 only needs to be done once. The iSteam 2.0 App can be downloaded from the App Store or Google Play.
mr Controls .steam __________________________________________________________________ ® User Settings Set Temperature Screen Pressing the User 1, User 2 or User 3 button before pressing the START button will automatically load the user settings. User 1 and User 2 settings are stored in iSteam 2.0 and cannot be adjusted from the App. User 3 settings are stored in the app. To adjust the User 3 settings, press and hold the User 3 button.
mr Controls .steam __________________________________________________________________ ® Care Tips Use only mild soap and water on a soft cloth to clean the control. Do not use abrasive cleansers Safety and Operating Information ! WARNING Set the steam bathing duration and tempera- ture according to personal preference, however it is highly recommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels. Set the duration at 10 minutes max.
mr.steam ® Feel Good Inc. www.mrsteam.com Products, information and specifications are subject to change without notice. For more information call Sales & Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information. mr.steam ® Sussman-Automatic Corporation® I hello@mrsteam.com I www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 I 9410 S. La Cienega Blvd.