Installation, Operation and Maintenance Manual Steambath Generator Systems Residential Models: MS90E – MS400E and MSSUPER1E – 3E ____________________ IMPORTANT: Leave this material with the home owner. ____________________ mr.steam ® Feel Good Inc.
READ ME FIRST! As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and operation of this generator. These are types of potential hazards that may occur during installation and operation: When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTRUCTIONS 2.
RESIDENTIAL STEAMBATH GENERATOR SYSTEMS INSTALLATION, OPERATION MODEL _______________________________ & MAINTENANCE MANUAL MODELS: MS90E, MS150E, MS225E, MS400E, MSSUPER1E, MSSUPER2E, MSSUPER3E SERIAL NO. ___________________________ TABLE OF CONTENTS Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Select Your MrSteam Model . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Generator Specification Chart . . . . . . . . . . . . . . . . . . . . . . . . .
mr Installation, Operation & Maintenance Manual .steam __________________________________________________________________________ ® SELECT YOUR MrSteam In considering the purchase or use of this steambath system, please note that if you are pregnant, have a coronary condition, are in poor health, are being treated for any other medical condition, or are using medication or drugs, MrSteam recommends that you obtain the approval of a physician before use.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam _________________________________________________________________________ ® BEFORE INSTALLING volume and construction. If any questions, please refer to MrSteam sizing and selection guide on page 3. Carefully inspect the Steam Generator and packaging for shipping damage. In the event of shipping damage, please contact the carrier for claim information. Our customer service department can assist you with any missing or damaged parts.
® WATER QUALITY INFORMATION For optimum results, the water supply should be tested prior to installation. If the mineral content exceeds the following recommended limits, various external treatment processes are recommended to correct the problem. An analysis of the on-site water must be made by a recognized and reliable water treatment company to ascertain the existing condition and treatment required. Poor water quality can affect efficiency or result in steam generator damage.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam _________________________________________________________________________ ® TYPICAL MrSteam INSTALLATION Provide unions as required to facilitate installation and disconnect of piping Drawings for illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction details. The control features an integral temperature sensor.
® TYPICAL MULTI-INSTALLATION INSTRUCTIONS (shown with optional AutoFlush) 1. Install each steam generator as in a single installation. Install generators as close as practical to each other, not exceeding 10 feet. The interconnecting cable length is 12 feet. 2. Shock Hazard. Power must be disconnected at the main electrical supply. Remove steam generator covers. Retain screws and covers for reuse. 3.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .
® INSTALLING THE ROUND OR SQUARE AROMASTEAM STEAMHEAD (1⁄2" NPT) 1/8" minimum clearance required when Acrylic Shield is used. A 1 ⁄2" clearance hole around the steam pipe is needed to mount the steamhead. STEP 1 Locate steam head 6-12 inches above floor, except for: 1. Tub/shower enclosures, install 6 inches above tub top edge. 2. For enclosures with acrylic or other non-heat resistant flooring install Acrylic Shield Part Number 103938. 3.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam _________________________________________________________________________ ® GENERATOR DIAGRAM Water Inlet Control & Accessory Connections Steam Outlet Safety Valve Optional AutoFlush Manual Drain Valve J IMPORTANT NOTES: Provide a minimum of (12) inches at both ends and top of the steam generator or as required for servicing.
® ELECTRICAL CHART ________________________________________________________________________________________________________ ELECTRICAL Vol Max Room Model No. (Cu. Ft.*) KW All electrical wiring to be installed by a qualified licensed electrician in accordance with National Electrical Code and local electrical code. POWER WIRING See “Field Power Wiring” Diagrams (below) 1. Check power voltage. Use 240V rated unit when supply is greater than 208V. (Most homes have 240V, 1PH service).
I N S TA L L E R mr Installation, Operation & Maintenance Manual .
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam __________________________________________________________________________ ® MULTI-INSTALLATION INSTRUCTIONS 1. Install each unit as in a single installation. Install the two generators as close to each other as possible. Shock Hazard. Power must be disconnected at the main electrical supply before removing steam generator covers. 3.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam _________________________________________________________________________ ® INITIAL START-UP AND CHECKOUT 1. Turn on control. Follow specific instructions provided with controls. 2. Steam will begin to appear in approximately 5 minutes (unless equipped with factory-installed Express Steam option) at the steam head.
® SYSTEM STATUS CODES The control (either iSteam®, AirTempo®, iTempo® or iTempo/Plus®) may display a status code if the steam generator is not functioning properly. Code H20 Code Meaning Water level is not satisfied within 5 min. Probable Cause Suggested Remedy Water Supply is off Turn on Water Supply Defective water feed solenoid Check/replace water solenoid valve Water feed probe not functioning Check/clean probe. Check probe wiring.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam _________________________________________________________________________ ® Steam Generator OPTIONAL AUTOFLUSH® 3 Pin Connector for AutoFlush Box Contents AutoFlush Valve with Cord Installation Instructions. OPERATION The optional AutoFlush System feature automatically drains the MrSteam generator following each use.
® OPTIONAL CONDENSATION PAN MrSteam strongly recommends the use of a condensation pan in the unlikely event of a plumbing leak. Locate the condensation pan on a solid level surface and place the steam generator inside the condensation pan. Insure the steam generator is level (see page 5 for locating the steam generator). All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable national and local codes.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam _________________________________________________________________________ ® PARTS IDENTIFICATION DIAGRAMS Contactor MS REGULAR MODELS: MS90E - MS400E (with AutoFlush®) shown with cover removed Liquid Level Probe Liquid Level Control Board Transformer Water Feed Solenoid Power Supply Knock-Out Water Inlet Plug and Play Connection (see pg. 16) Steam Outlet Access Cover Safety Valve FOR ILLUSTRATIVE PURPOSES ONLY.
® REPLACEMENT PARTS LIST ___________________________________________________________________________________________________________ Part No. Description Generator 99178MS Drain Valve All Models 99297 Safety Valve 15PSI All Models 100479 Water Feed Solenoid Valve w/filter All Models 10477-3 Transformer 24VAC All Models 104288 Liquid Level Control Board All Models 103904 Tandem Cable for 2 generators (12 ft.) All Models 103917 Tandem Cable for up to 5 generators (30 ft.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam _________________________________________________________________________ ® CONTROL INSTALLATION Refer to Control Manual for specific installation requirements BEFORE INSTALLING DO NOT route iSteam, AirTempo, iTempo/Plus, iTempo, HomeWizard or iGenie control wiring inside conduit together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation.
mr..steam steam Installation, Operation & Maintenance Manual __________________________________________________________________________ mr Installation, Operation & Maintenance Manual __________________________________________________________________________ H O M E O W N E R S E C T I O N ® ® READ ME FIRST! As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and operation of this generator.
HOMEOWNER mr Installation, Operation & Maintenance Manual .steam __________________________________________________________________________ ® SETTING THE STEAM BATH TEMPERATURE AND DURATION Set the steam bathing temperature according to personal preference, however it is highly recommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels. Set duration to a maximum of 10 minutes to gauge comfort and safety levels.
® USING MrSteam ESSENTIAL OILS Enjoy AromaSteam essential oils by placing a drop or two into an unheated AromaSteam steamhead as shown in the illustration. Only use MrSteam AromaSteam essential oils in the MrSteam AromaSteam steamhead. AromaSteam 10ml bottle with integrated dropper Essential oils and/or aroma therapy can cause inflammation, burns, headache, nausea and allergic reactions. Consult a physician before using aromatherapy. Recess for essential oil (Items 1-4) 1.
NOTES
NOTES
mr.steam ® Feel Good Inc. ® www.mrsteam.com Products, information and specifications are subject to change without notice. Please call Sales & Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information. mr.steam ® Sussman-Automatic Corporation® I hello@mrsteam.com I www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 1 800 76 STEAM I 9410 S. La Cienega Blvd. Inglewood CA 90301 1 800 72 STEAM 2020 © Sussman-Automatic Corporation I MrSteam and des.