General Guidelines for Installing Mr.
The directions detailed in this guideline are designed to familiarize the reader with a general understanding of the installation of a variety of Mr. Steam products. For complete and important detailed Installation, Operation and Maintenance information, it is recommended that reference be made to the specific Mr.Steam® installation manual that accompanies each Mr. Steam product. Any questions, feel free to contact Mr.Steam® at 1-800-76-Steam, hello@mrsteam.com or visit www.mrsteam.com Generator Location .
GENERATOR LOCATION Locating the Mr.Steam Generator ® Select a location as near as practical to the steam room. Typical locations include: closet, vanity cabinet, climate controlled attic or basement. 1. Locate steambath generator within 60 feet of steam room. Note: The standard length of the cable for connecting the control to the steam generator is 30 feet. The steam generator and control must be located accordingly. A 30 foot cable is standard. Contact Mr.Steam to purchase an optional 60 ft.
Main Electrical Disconnect Panel 240v Powerline L1, L2, Ground to be field wired Please refer to the wiring diagram in the Mr.Steam Installation Manual for complete wiring information. POWER CONNECTION Field Power Supply Connection _________________________________ TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLY TO ELEMENTS!!! ________________________________ NOTE: For illustrative purposes only. Consult with qualified licensed electrician for electrical installation.
1. Connect cold water line. 2. Provide a shut off valve in the water supply line upstream of the steambath generator. Water Feed Line (3/8” NPT) WATER FEED Water Feed 3. Do not overheat inlet solenoid valve with solder connections. Overheating will damage parts. 4. Flush inlet water line thoroughly before making connection to unit. 5. Strainer recommended upstream of feed water connection. 6. For best performance water pressure should be 15 to 20 PSIG. Reduce pressure as required if necessary. 7.
Steam Outlet (1⁄2” NPT) 1. Do not install any valve in steam line. Flow of steam must be unobstructed. 2. Use 1⁄2” brass pipe or copper tubing from unit to steam head as permitted by codes. Steam Outlet Pipe STEAM OUTLET Steam Outlet Pipe 3. Insulate steam line using pipe insulation rated 250˚ F or higher. 4. Pitch steam line 1⁄4” per foot towards steam head or steam generator to avoid valleys and trapping of condensation.
DRAIN LINE Manual Drain Line Drain (1⁄2” NPT) NOTE: A drain valve is provided to facilitate servicing. Provide a drain line connection from steambath generator drain valve according to national and local codes. Check local plumbing code for receptor, trap and vent requirements. Unit drains by gravity. Manual Drain Valve (Shown in open position) Pitch as required for Gravity Drain For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details.
AutoFlush Optional AutoFlush Steam Generator Operation The optional AutoFlush System feature automatically drains the Mr.Steam® system following each use. A time delay allows the water to cool down (about two hours) before it drains by gravity for a safe and gentle operation. NOTE: If the Express Steam option has been installed, the AutoFlush will drain for ten minutes then refill with fresh water to begin the pre-heat cycle.
DRIP PAN Drip Pan PN 103867 Drip Pan 3/4” Outlet For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details.
Express Steam Express Steam (only available factory installed) Suitable for all MS Models. Express Steam is equipped with a low power heating element and thermostat to keep the water in the tank warm enough to produce steam quicker. All Express Steam components and wiring are installed at the factory. No additional wiring or plumbing is required by installers.
GENERATOR SCHEMATIC Generator Schematic (MS SUPER 2E shown) Power Block Fuses Liquid Level Control Board Contactor Transformer Liquid Level Probe Water Feed Solenoid Power Supply Knock-Out Water Inlet Plug and Play Connection Access Cover Safety Valve Steam Outlet Express Steam Heater (optional) AutoFlush Valve (optional) Heating Element Stainless Steel Tank Drain Line 10
TANDOM INSTALLATION Tandem Steam Generator Installation (MS Super 4E, 5E & 6E)* Standard Tandem Cable for Connecting (2) Units PN 103904 • Optional Tandem Cable for Connections up to (5) Units PN 103917 Secondary Unit Primary Unit (Unit control connected to Primary Unit) *Refer to the Mr.Steam Installation manual for additional installation information. For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details.
iSteam CONTROL iSteam Control 12
iSteam INSTALLATION Installing the iSteam Control Install the iSteam Control according to the installation and operation instructions supplied with the Control. Failure to do so may result in an inoperative control and a hazardous condition. 1. Plug the 30’ control cable into the iSteam control pigtail. The iSteam pigtail is the longer cable with the ID tag. 2. If the optional AudioWizard is used, remove the red Cap from the AudioWizard pigtail and plug it into the AudioWizard cable. 3.
Locate control where it will sense general room temperature and NOT direct steam emission from the steam head. iTempo CONTROLS iTempo® and iTempo Plus® Controls Refer to the Mr.Steam iTempo Installation Manual for complete control installation information.
1. Firmly connect the connector to the control. Turn on power to the steam generator and test the control to verify correct connections. Test per instructions. Proceed with installation and verification of proper control function. IMPORTANT: Turn power to the steam generator OFF before installing the control. Failure to turn the power OFF will result in an inoperable control. 2. Remove and discard peel-off paper to expose adhesive liner. 3.
MSTS Remote Temperature Sensor Locate the Remote Temperature Sensor (MSTS) where it will sense general room temperature and NOT direct steam emission from the steam head. Refer to the Mr.Steam Installation manual for additional control installation information. REMOTE TEMPERATURE SENSOR Locating Controls Outside the Steam Room by Using Remote Temperature Sensor For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details.
The Remote Temperature Probe is required when a steam control is installed outside the steam room. 1. The probe must be installed: a. On a vertical surface. b. 4-5’ above the floor. Locate the probe in a location representative of the desired steambathing temperatures. Do not locate the probe above or near the steam head or direct steam emissions. The probe has an integral 20 ft. cable. Ensure that the probe and iSteam control are located accordingly. Diagram 1 2. Drill a 1/4” hole in the wall.
CONTROL CABLE CONNECTION Connecting the Control Cable to the Steam Generator Route the control cable (provided with the control) from the wall cutout to the steam generator. IMPORTANT: Do not strain, staple, pinch or otherwise damage the control cable. Route cable as required to permit replacement. The 30’ (and optional 60’) control cable features identical Mini-Din connectors at both ends. Note: The standard length of the cable for connecting the control to the steam generator is 30 feet.
® • Fully automatic water resistant remote control with color indicating status ring and magnetic docking port. • Activate your steam shower from anywhere in the home - Wirelessly. • Initiates preheat of steam shower up to 100 feet away. • Penetrates walls! Radio Frequency activated. • Easy Plug & Play connection. • Comes standard with interface module. • Can be easily connected with any Mr.Steam® Bath Generator (No upgrade required).
Electronic oil delivery system evenly infuses aroma into steam for an aromatherapy experience. Complete with in-shower control, oil container caddy, hoses, fittings and oil atomizer. AromaSteam Essential Oils are available in one-liter bottles. Not for use with acrylic or fiberglass rooms. AromaSteam SYSTEM AromaSteam™ System Locate Aroma steam system in an easily accessible location so as to monitor the consumption of essential oils and for easy replacement. NOTE: Cables should not contact steam pipe.
Oil Well Step 1 Attach Locating Nipple to steam line. Step 2 Provide a 1 ½” hole in finished wall to mount the steamhead. Step 3 Remove Locating Nipple and attach steam head. AromaSteam INSTALLATION AromaSteam™ Steamhead and Optional Acrylic Shield Installation NOTE: Steamhead to be installed 6-12” above the floor. A 1.5” diameter hole in the steamroom is required to mount the steamhead. Refer to the AromaSteam Steamhead Manual for additional installation information.
Enjoy essential oils by placing a drop or two into your steamhead as shown in the illustration. CAUTION: Use essential oils with caution. Essential oils are for external use only. Keep out of reach of children. Essential oils are highly concentrated and are potent substances and should not be applied directly to the skin as they can be irritants. Use essential oils with caution. CAUTION: Place the drops into the Mr.Steam AromaSteam steamhead well prior to turning on the steambath.
LED light suffuses steam environment with multiple colors, from airy blue to sensual red. Ceiling mounted, vapor-sealed, low-voltage LED module for steam shower enclosure of any size. The ChromaSteam system is complete with LED light and color election microprocessor. ETL Listed. Light Fixture NOTE: for mood lighting only. The ChromaSteam System is not a substitute for general illumination. Consultation with architect, designer and or contractor on room design and construction is strongly recommended.
Mr. Steam’s AudioWizard offers fully integrated audio control inside the steam room and or shower. With an integrated Blue Tooth Audio Streaming System, the AudioWizard can pair up to eight devices and four in-shower speakers. INSTALLATION 1) Locate the AudioWizard The AudioWizard control cable is 30ft and the power cord is 6ft, ensure the control and AudioWizard are located accordingly. Locate in a dry location where the wireless signal will not be interrupted.
Speakers Rotate out for speaker installation in wall or ceiling MS-Speakers • Two 51⁄2” diameter flush-mount two-way speakers for steam or shower use, polypropylene cones or ABS frames with grills. Silicone RTV Apply silicone bead around entire speaker • Suitable for almost any source of audio input. • Rated 60W peak power 8 ohms impedance with 1” tweeter for full range sound. • Use only CL2 or CL3 UL listed wires to connect speakers to audio source. • Available in round and square designs.
MS-Seat Teak wood seat drops for use and folds for storage. Dimensions are: 19 5⁄8” w x 12 5⁄8” d x 11⁄4” Max 250 lbs.
facebook.com/mrsteamtherapy twitter.com/steamtherapy pinterest.com/steamtherapy youtube.com/steamtherapy Sussman-Automatic Corporation® 43-20 34th Street, Long Island City, NY 11101 Tel: 718 937 4500 Fax: 718 472 3256 9410 S. La Cienega Blvd. Inglewood CA 90301 Tel: 310 216 6565 Fax: 310 216 2944 houzz.com/mr-steam 2013 © Sussman-Automatic Corporation MR. STEAM and des., A LIFETIME OF PLEASURE, AROMAFLO, AUTOFLUSH, CLEAN STEAM...