Installation Guide

Steam Outlet Pipe
Steam Outlet (
1
2
” NPT)
1. Do not install any valve in steam line. Flow of steam must
be unobstructed.
2. Use
1
2”
brass pipe or copper tubing from unit to steam head
as permitted by codes.
3. Insulate steam line using pipe insulation rated 250˚ F or
higher.
4. Pitch steam line
1
4
per foot towards steam head or steam
generator to avoid valleys and trapping of condensation.
NOTE: Running the steam line down and then up will create
a steam trap blocking the flow of steam.
NOTE: A 1.5” hole in the steamroom is required to mount
the steamhead.
STEAM OUTLET
5
Steam Outlet
Pipe
For Illustrative purposes only. Consult with qualified designer,
architect or contractor for steamroom construction details.