Installation, Operation & Maintenance Manual ™ iTEMPO & iTEMPO/PLUS mr.steam ® ™ CONTROLS Feel Good Inc. www.mrsteam.
Table of Contents: General Information.........................................1 Before Installing ............................................1-2 Dimensional Information..................................3 Installations ...................................................4-7 Installing the Remote Temperature Probe ...................................8-10 iTempo Operating Instruction...................11-12 iTempo/Plus Operating Instruction...........13-16 Care and Maintenance..................................
mr.steam ® Installation & Operating Instructions _____________________________________________________________ BEFORE INSTALLING Carefully inspect the control and packaging for shipping damage. In the event of shipping damage, please contact the carrier for claim information. Our customer service department can assist you with any missing or damaged parts. ! WARNING A peel and stick warning sticker is provided in the MrSteam steam generator Installation, Operation and Maintenance Manual.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ BEFORE INSTALLING (cont.) Install the iTempo or iTempo/Plus controls according to installation instructions. Failure to install according to instructions will result in an inoperative control or hazardous overheating or inadequate heating of the steam room.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ 21/2” Dimensional Information for the Round and Square iTempo™ and iTempo/Plus™ BOX CONTENTS: • iTempo™ or iTempo/Plus™ Control • Control Cable (30 ft.) • Steam head • Tube of Silicone Sealant • Owner’s Manual 41/2” 1” 3/ ” 8 5” 1/4” 5” 3/ ” 4 12” long pigtail Drawings for Illustrative Purposes Only.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ Installation Instructions for Round & Square iTempo™ and iTempo/Plus™ STEP 1 Determine the desired installation location of the control. The iTempo™ and iTempo/Plus™ controls are designed to be installed inside or outside the steam room as a matter of personal preference.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ STEP 2 Diagram 1 Make a 2-5⁄8” wide by 3-7⁄8” high cutout in the desired control location. Do not oversize or undersize the cutout. STEP 3 Diagram 2 Route the control cable (provided with the control) from the wall cutout to the steam generator. Connect one end of the cable to the steam generator connector. NOTE: The connector is keyed with the flat facing up.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ DIAGRAM 4 ! CAUTION If the generator is on for more than a few minutes steam will start coming out of the steamhead. Insure that steamroom is not occupied. STEP 5 Diagram 4 Remove and discard peel-off paper to expose adhesive liner. STEP 6 Diagram 5 Run a bead of silicone (provided) as shown to the outer edge of the control faceplate, following the contour of the circle or square shape.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ IMPORTANT NOTE: Do not apply excessive amounts of silicone. Do not apply silicone to any other parts of the control including the adhesive gasket. STEP 7 Diagram 6 Insure the mounting surface is clean and dry as required for good adhesion. Hold the control with the LED display in the 12 o'clock position and press the control against the wall until the adhesive sticks and holds firmly.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ Installing the Remote Temperature Probe (PN: MSTS) The Remote Temperature Probe is required when the iTempo or Tempo/Plus Controls are installed outside the steam room. ! CAUTION The Remote Temperature Probe (P/N MSTS) is for use with iTempo and iTempo/Plus Controls only. Do not use with any other controls. Do not use any other temperature probe with the iTempo and iTempo/Plus controls.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ Temperature Probe Connection Knock-Out Temperature Probe Cable (30 feet) Mr.Steam Steam Generator (shown with cover removed and NOT installed) DIAGRAM 1 Drawings for Illustrative Purposes Only.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ 5. Route the end of the probe cable with the temperature probe through the wall into the steam room as shown in Diagram 2. IMPORTANT NOTE: Do not strain, staple, pinch or otherwise damage the probe cable. 6. With a minimal length of the cable exposed apply silicone (provided) to the hole in the wall as required to create a moisture seal as shown in Diagram 2. 7.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ iTempo™ Operating Instructions The iTempo Control features programmable digital temperature control, a fixed (60) minute duration, ON/OFF and PAUSE.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ TIMER FEATURE When the control is turned ON a 60 minute time duration is initiated. The control will turn off after 60 minutes unless the control is turned off manually. MEMORY FEATURE If the control is turned off manually before 60 minutes then the default temperature of 110˚F will be used the next time the control is turned on.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ iTempo/Plus™ Operating Instructions The iTempo/Plus Control features programmable temperature control, programmable time duration, clock, AromaSteam, ChromaSteam®, ON/OFF and two personal settings. mr.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ iTempo/Plus™ Operating Instructions (cont.) SETTING THE CLOCK Diagram 3 When the display is not flashing: Press and hold the TIME key until the display starts flashing. Use the UP/DOWN keys to select the desired time, at this time the AM/PM logo will be displayed. Press the TIME key to save changes. NOTE: The clock can only be set when the generator is off.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ SETTING THE TEMPERATURE Diagram 6: Press TEMP key to set the desired temperature or display the temperature setting. Diagram 7: The control is preset and will display a temperature setting of 110˚F (default setting). With the temperature displayed, press the UP or DOWN keys to set the desired temperature (80°F to 120°F) in one degree increments.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ CHANGING THE TEMPERATURE UNITS (˚F/˚C) When the generator is Off, Press and hold ON/OFF key for 10 seconds. The temperature units will be displayed as Fahrenheit (TuF) or Celsius (TuC). Use the UP/DOWN keys to choose between (TuF) and (TuC). Press ON/OFF key to accept the new value and exit. aroma mr.
mr.steam ® Installation & Operating Instructions ______________________________________________________________ Display mr.steam Up Key Time Display/ Adjust Key temp ON/OFF Key time aroma chroma AromaSteam Key Time Display/ Adjust Key Down Key Program Key ChromaSteam Key Care Tips for all Controls and Steamheads 1. Use only mild soap and water on a soft cloth to clean the control and steamhead. 2. Do not use abrasive cleansers 3.
TEMPLATE FOR CONTROL INSTALLATION ( SEE PG . 4 ) mr.steam ® 2-5⁄8” Feel Good Inc. Products, information and specifications are subject to change without notice. 3-7⁄8” For more information call Sales & Support at: 1.800.76.STEAM (East Coast) 1.800.72.STEAM (West Coast) 2013 © Sussman-Automatic Corporation Mr.Steam and des., AromaFlo, AutoFlush, AutoSteam, Butler Package, ChromaSteam, Clean Steam...