Installation, Operation and Maintenance Manual Steambath Generator Systems Residential Models: MX4E-6E ____________________ IMPORTANT: Leave this material with the homeowner. ____________________ mr.steam ® Feel Good Inc.
RESIDENTIAL STEAMBATH GENERATOR SYSTEMS Installation, Operation and Maintenance Manual MODELS: MX4E, MX5E, MX6E MODEL ____________________________ SERIAL NO. __________________________ INSTALLER'S SECTION: IMPORTANT SAFETY INFORMATION . . . . . . . . . . . . . .2-3 PRE-INSTALLATION INFORMATION Steam Room Guidelines . . . . . . . . . . . . . . . . . . . . . . . .4 Water Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 STEAM GENERATOR Locating the Steam Generator . . . . . . . . .
mr.steam Installation, Operation & Maintenance Manual __________________________________________________________________________ ® I N S TA L L E R S E C T I O N IMPORTANT SAFETY INFORMATION As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and operation of this steam bath systems.
® IMPORTANT SAFETY INFORMATION (cont.) Applies to 18-23 18. This document contains important safety, operation and maintenance information. Leave this document with the homeowner. Do not discard this document. 19. Consider any controls and accessories before installation. Read the Installation and Operation Manual of all controls and accessories available at www.mrsteam.com. 20. Record the model and serial number of the steam generator in the space provided in the table of contents of this manual. 21.
I N S TA L L E R mr Installation, Operation & Maintenance Manuals .steam ______________________________________________________________________________ ® PRE-INSTALLATION CONSIDERATIONS STEAM ROOM GUIDELINES To prevent slip and fall hazards, non-slip flooring or non-slip floor strips must be installed in the steam room. Applies to 1-9 1. The steam room must be completely enclosed, with full walls, door, floor and ceiling as required to contain the steam and prevent moisture damage outside the steam room.
mr Installation, Operation & Maintenance Manuals .steam ________________________________________________________________________ LOCATING THE STEAM GENERATOR Applies to 1-6 Applies to 12-18 1. Do not route iSteam, AirTempo, iTempo/Plus, iTempo OR any control wiring inside conduit together with power lines or close to hot water or steam piping. Doing so may result in an inoperative or hazardous installation. 2.
I N S TA L L E R mr Installation, Operation & Maintenance Manuals .steam ______________________________________________________________________________ ® CHECKING STEAM GENERATOR FOR CORRECT SIZING Materials of construction, room size and special design features such as large glass areas, all affect the steam generator model selection. 1. Measure length, width & height in feet of the steam/shower or tub/shower Multiply the Length ____ x Width_____ x Height _____ = ROOM VOLUME 2.
® STEAM GENERATOR CLEARANCE SPECIFICATIONS Applies to 1-2 1. Do not install MAX series inside a vanity or other small enclosed spaces. Do not install under the steam room bench. Installing the MAX steam generator in a small enclosed space may result in elevated temperatures and an inoperable steam generator. 2. Locate the MAX series generator in a room with ventilation as required to prevent an increase in ambient temperature.
I N S TA L L E R mr Installation, Operation & Maintenance Manuals .steam ______________________________________________________________________________ ® STEAM GENERATOR DIMENSIONS E D C % A J F L K 18” for servicing M I G H Dimensions MX4E-6E A B C D E F G H I J K L M 9 3⁄4 (248) 11 (280) 16 1⁄2 (419) 20 3⁄4 (527) 1 3⁄8 (34) 2 3⁄8 (60) 7 5 ⁄8 (150) 5 7⁄8 (150) 7 7⁄8 (200) 1 7⁄8 (48) 251⁄8 (638) 2 3⁄8 (60) 6 3⁄8 (162) NOTES: 1. M=Optional AutoFlush.
® PARTS IDENTIFICATION DIAGRAM Contactors (shown with AutoFlush® with cover removed) Transformer Fuses Circuit Board Transformer ALL DRAWINGS FOR ILLUSTRATIVE PURPOSES ONLY. Some components may be omitted or altered for clarity. Do not use for wiring, plumbing, repair or other purposes not related to component identification.
I N S TA L L E R mr Installation, Operation & Maintenance Manuals .steam ______________________________________________________________________________ ® PLUMBING DRAIN (1" NPT) GENERAL Applies to 1-3 1. All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable National and local codes. Applies to 2-4 2. Use unions on all pipe connections as required for service and removal of the steam generator. 3. Use only brass piping or rigid copper tubing.
® STEAM SUPPLY PLUMBING (3⁄4" NPT) Union 1/2” Steam Supply Fitting STEAM GENERATOR 3/4” Steam Piping STEAM ROOM Tee Fitting 6-12” Above Floor SteamHeads Min. 1 ALL DRAWINGS FOR ILLUSTRATIVE PURPOSES ONLY. 6” STEAM PIPING (1⁄2" NPT) Applies to 1-5 Steam Piping 1. Do not install any valve in steam piping. The flow of steam must be unobstructed. 2. MAX Steam Generators must be installed with two or more steamheads.
I N S TA L L E R mr Installation, Operation & Maintenance Manual .steam ___________________________________________________________________________ ® 1/8" minimum clearance required when Acrylic Shield is used. See installation STEAMHEAD INSTALLATION 2. Because the steamhead and direct steam emissions are very hot, locate the steamheads where incidental contact by bather with the steamheads or direct steam emission cannot occur. instructions provided with the Acrylic Shield.
® ELECTRICAL Applies to 1-9 1. Never use damaged equipment, doing so may result in an inoperative or hazardous installation. 2. All electrical wiring installation to be performed by a qualified licensed electrician in accordance with National Electrical Code and Local Electrical Code. 3. Connect electrical power supply to the power block only. Do not connect power supply directly to elements.
® SINGLE PHASE 208/240 VOLT WIRING DIAGRAM MODELS MX4E, MX5E, MX6E POWER INPUT TRANSFORMER 2/4PL Terminal Block EXPRESS STEAM (optional) WATER FEED SOLENOID VALVE FUSES GROUND CONTACTOR I N S TA L L E R mr Installation, Operation & Maintenance Manual .
® CONNECTING MULTIPLE GENERATORS Applies to 1-2 4. Connect the generators with a tandem cable as follows: • Use Tandem Cable part number 103904 to connect two generators (cable is 12' long) • Use Tandem Cable part number 103917 to connect 3-5 generators (cable is 30' long). 5. Remove one knock-out on each generator. Insert the ends of interconnecting cable through the knock-outs. Connect each end to the circuit board as shown. 6. Connect separate plumbing and power supplies for each unit. 1.
I N S TA L L E R mr Installation, Operation & Maintenance Manuals .steam ______________________________________________________________________________ ® TROUBLESHOOTING Applies to 1-2 1. Electric shock hazard. MrSteam steam generators are connected to high voltage and contain live electrical components. All installation and service to be performed by qualified and licensed electricians only.
® EXPLANATION OF THE STATUS CODES DISPLAYED ON THE CONTROL The control (either iSteam®, AirTempo®, iTempo® or iTempo/Plus®) may display a status code if the steam generator is not functioning properly. Code H20 Code Meaning Water level is not satisfied within 5 minutes Probable Cause Suggested Remedy Water Supply is off Turn on Water Supply Defective water feed solenoid Check/replace water solenoid valve Water feed probe not functioning Check/clean probe.
A S S E S S O R I E S CONTROL INSTALLATION Refer to Installation Instructions for the specific control Applies to 1-7 1. Install the iSteam, AirTempo, iTempo or iTempo/Plus controls according to installation instructions, provided with the controls. Failure to install according to instructions will result in an inoperative control or hazardous overheating or inadequate heating of the steam room. 2.
Installation, Operation & Maintenance Manuals OPTIONAL AUTOFLUSH® Steam Generator OPERATION 3 Pin Connector for AutoFlush The optional AutoFlush automatically drains the generator following each use. A time delay allows the water to cool down (about two hours) before it drains by gravity for a safe and gentle operation. At the start of the flush cycle, the generator will drain and fill with water at the same time.
I N S TA L L E R mr Installation, Operation & Maintenance Manuals .steam ______________________________________________________________________________ ® 10. The steam generator drains by gravity. Plumb all drain lines accordingly. 11. The Drain is open when the Drain Valve handle is aligned with brass nipple. 12. Connect the AutoFlush cord connector to the three pin connector as shown. 13. Plumbing to be performed by a qualified plumber and shall be in accordance with applicable national and local codes.
® IMPORTANT! This Installation, Operation and Maintenance Manual includes information for safe and reliable installation of the residential steam generator. MrSteam offers numerous options and accessories for use with the steam generator. Some of the options and accessories must be considered when installing the steam generator as they require special plumbing, electrical or space accommodations.
mr.steam Installation, Operation & Maintenance Manual __________________________________________________________________________ H O M E O W N E R S E C T I O N ® IMPORTANT SAFETY INFORMATION As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and operation of this steam bath system.
® IMPORTANT SAFETY INFORMATION Applies to 14-17 14. The wet surfaces of steam enclosures may be slippery. Use care when entering or leaving. 15. The steamhead is hot. Do not touch the steamhead and avoid the steam near the steamhead. 16. The information in this manual should be used in conjunction with consultations with an architect, designer and contractor in determining factors necessary in providing a suitable and safe steam room. 17.
HOMEOWNER mr Installation, Operation & Maintenance Manual .steam __________________________________________________________________________ ® CARE TIPS FOR ALL CONTROLS AND STEAMHEADS 1. Use only mild soap and water on a soft cloth to clean the control and steamhead. 2. Do not use abrasive cleansers. 3. If the decorative cover is damaged on the iTempo or iTempo/Plus call MrSteam technical service for replacement parts.
mr.steam ® Feel Good Inc. ® www.mrsteam.com Products, information and specifications are subject to change without notice. Please call Technical Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information. The model and serial number is printed on the data plate on the front of the steam bath generator. Have this information available when contacting Technical Service. mr.steam ® Sussman-Automatic Corporation® I hello@mrsteam.com I www.mrsteam.