Installation Guide
mr
.
steam
®
Installation, Operation & Maintenance Manuals
I N S T A L L E R
20
______________________________________________________________________________
Applies to 1-7
1. MrSteam strongly recommends the use of a condensation
pan in the unlikely event of a plumbing leak.
2. Locate the condensation pan on a solid level surface
and place the steam generator inside the condensation
pan. Ensure the steam generator is level (see page 5
for locating the steam generator).
3. All plumbing shall be performed by a qualified licensed
plumber and in accordance with applicable national
and local codes. Check local plumbing code for
receptor, trap and vent requirements.
4. Condensation pans drain by gravity.
5. The condensation pan is equipped with an integral female
3
⁄4" NPT
fitting for connection to the drain.
6. Do not plumb the generator drain and condensation pan
drain together in such a way that will cause drain water to back
into condensation pan and cause a leak and property damage.
7. See pages 10-11 for complete drain line and plumbing instructions.
10.
The steam generator drains by gravity. Plumb all drain lines accordingly.
11.
The Drain is open when the Drain Valve handle is aligned with brass nipple.
12.
Connect the AutoFlush cord connector to the three pin connector as shown.
13.
Plumbing to be performed by a qualified plumber and shall be in accordance with
applicable national and local codes.
14.
Unit drains by gravity. A drain line that is lower than the AutoFlush® assembly must be available.
15.
The AutoFlush valve outlet is 1“ NPT.
16.
Use copper or brass nipple 1“ NPT x 31⁄2“ or longer (not supplied) to connect AutoFlush valve
(end "B") to the Drain Valve (valve end “A” and “B” are indicat-ed on bottom of AutoFlush Valve).
17.
An arrow on the AutoFlush valve indicates the correct direction of flow.
18.
To Check Operation:
1.
Turn ON control and allow tank to fill with water.
2.
Turn OFF control. Water should stay in tank.
3.
Turn OFF power at the panel box. Water should discharge from tank.
4.
Turn ON power at panel box.
5.
Repeat.
OPTIONAL CONDENSATION
PAN