Installation Guide
mr
.
steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
STEAM GENERATOR MAINTENANCE
MrSteam steambath generators require little maintenance. Other
than periodic draining, maintenance procedures are minimal. Every 2
months, or more often in “hard” water areas, the manual drain valve
should be opened fully flushing out accumulated materials, salts and
other particles which are natural by-products of boiling water.
Applies to 1-2
1. Draining immediately after a steam cycle may
expose PVC and other piping to high temperature water.
Check local codes. The unit will refill automatically when the
control is activated again. In areas of hard water, a MrSteam
AutoFlush
®
system is recommended for generator longevity.
2. Failure to allow the water to cool will expose the equipment and
user to scalding water and cause property and personal injury.
Flush a minimum of 8 hours after the control has been turned off
to insure that the water has cooled.
24
H O M E O W N E R
WARRANTY
To view or download the MrSteam Residential Generator Warranty
and register your Product go to:
www.mrsteam.com
USING MrSteam ESSENTIAL OILS
Enjoy AromaSteam essential oils by placing a drop or two
into an unheated AromaSteam steamhead as shown in the
illustration. Only use MrSteam AromaSteam essential oils in
the MrSteam AromaSteam steamhead.
Essential oils and/or aroma therapy can
cause inflammation, burns, headache, nausea and allergic
reactions. Consult a physician before using aromatherapy.
Applies to 1-6
1. Use essential oils with caution. Essential oils are for
external use only. Keep out of reach of children.
Essential oils are highly concentrated and are potent
substances and should not be applied directly to the
skin as they can be irritants. Use essential oils with
caution.
2. Place the drops into the MrSteam AromaSteam steam-
head recess prior to turning on the steambath. Do not
place drops in a hot steamhead as serious injury can
result if you do not follow this warning.
3. Start with one drop to gauge strength and suitability.
Limit to a maximum of a few drops for a steam bathing
session.
4. The bather should exit the steambath immediately if
dizziness occurs. If skin irritation occurs stop using the
oils immediately. Remove any excess oil by washing in
AromaSteam steamhead
(install per instructions
on page 12)
Steam
emission
slot
AromaSteam
10 ml bottle
with integrated
dropper
Recess for
essential oil
CARE TIPS FOR ALL CONTROLS
AND STEAMHEADS
1. Use only mild soap and water on a soft cloth
to clean the control and steamhead.
2. Do not use abrasive cleansers.
3. If the decorative cover is damaged on
the iTempo or iTempo/Plus call MrSteam
technical service for replacement parts.
Replacement of the decorative
covers requires removal and reinstallation of the
control from the mounting surfaces.
mild soap and water. If ingested, rinse mouth with water.
Administer water or milk to dilute. Contact a physician
immediately.
5. Aromatic oils should be added to steamhead before
turn-
ing on the steambath unit. DO NOT add oil during steam
bathing or when the steamhead is heated.
6. Tightly close bottles when storing oils. Keep bottles away
from sources of ignition.