Installation, Operation & Maintenance Manual Steam@Home ® residential steam generator systems Models: SAH3000, SAH4500, SAH6000 ® mr.steam ® Feel Good Inc.
! WARNING states a hazard may cause serious injury or death if precautions are not followed. READ ME FIRST! Important Note: As you follow these instructions, you will notice warning and caution symbols. This blocked informa! CAUTION signals a situation where minor injury or tion is important for the safe and efficient installation, operation product damage may occur if you do not follow instructions. and maintenance of this generator.
Steam@home Residential Steambath Generator Systems installation , operation & maintenance manual ® MODELS: SAH3000, SAH4500, SAH6000 MODEL ____________________ Serial No.____________________ Table of Contents _______________________________________________________________ Information for Installers & Homeowners Read Me First! & Warning Sticker.. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Select Your MrSteam Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mr .steam Steam@Home __________________________________________________________________________ ® ® CORRECT SIZING IS important ! ! WARNI N G Selection of the appropriate model is impor- WARNING In considering a purchase of this steam- bath system, please note that if you are pregnant, have a coronary condition, are in poor health, are being treated for any other medical condition, or are using medication or drugs, MrSteam recommends that you obtain the approval of a physician before use.
® Before Installing Carefully inspect the Steam Generator and packaging for shipping damage. Please contact the carrier in the event of shipping damage, please contact the carrier for claim information. Our customer service department can assist you with any missing or damaged parts. ! WARNI N G Never use damaged equipment, doing so may result in an inoperative or hazardous installation. IMPORTANT NOTES: This document contains important safety, operation and maintenance information.
installer mr .steam Steam@Home ________________________________________________________________________ ® ® Installation, Operation & Maintenance Manual Water Quality Information IMPORTANT NOTE: For optimum results, the water supply should be tested prior to initial startup. If the mineral content exceeds the following recommended limits, various external treatment processes may be used to correct the problem.
® ® Installation, Operation & Maintenance Manual Typical Mr.Steam Installation NOTE: For illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction details. Provide unions to facilitate installation and disconnect of piping Field installed water supply line Field installed power supply SteamStart® Control See page 12 for installation information. IMPORTANT NOTE: Install cable in a dedicated conduit to allow for replacement.
installer mr .steam Steam@Home ________________________________________________________________________ ® ® Installation, Operation & Maintenance Manual INSTALLATION Plumbing All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable National and local codes. • Use unions on all pipe connections. • Use only brass piping or copper tubing as permitted by codes. • Do not use black, galvanized, PVC pipe or PEX. Water Supply (3⁄8” NPT) 1.
® ® Installation, Operation & Maintenance Manual Oil Well InstallATION of the Steam Head 1 ( ⁄2” NPT, PN 103937) Acrylic Shield (pn 103938) with Acrylic Shield (PN 103938) The Acrylic Shield (pn 103938) is for use when acrylic or other non-heat resistant materials are used for the steamroom enclosure.
installer mr .steam Steam@Home ________________________________________________________________________ ® ® ELECTRICAL All electrical wiring to be installed by a qualified licensed electrician in accordance with National Electrical Code and local electrical code. Power Wiring See “Field Power Wiring” Diagrams (below) 1. Check power voltage. Use 240V rated unit when supply is greater than 208V. (Most homes have 240V, 1PH service). Use 208V rated unit for 208V power. 2.
® ® Initial Start-Up and Checkout 1. Turn on control. Follow specific instructions pages 12. 2. Steam will begin to appear in approximately 5 minutes at the steam head. 3 .Steam will shut off automatically when 20 minute timer Installation, Operation & Maintenance Manual is up. To shut steam off manually, press SteamStart® again. To clear steam from enclosure area, turn shower on before opening door. 4.
® ® Installation, Operation & Maintenance Manual Single Phase 208/240 VOLT Wiring Diagrams SAH units are not available in 3 phase Models: SAH3000 SAH4500 SAH6000 LEGEND (All Diagrams) FIELD WIRING FACTORY WIRING SteamStart™ Liquid Level Control Board Explanation of LED Indicators _________________________________________________________________________________________________ Green LED is ON when there is 208/240 Volt incoming power connected, 24 Volt transformer secondary output and on-board 5 Volt
® ® Installation, Operation & Maintenance Manual Models SAH3000, SAH4500, SAH6000 shown with cover removed Contactor Transformer Liquid Level Control Board Water Feed Solenoid Power Supply Opening SteamStart™ Steam Outlet Safety Valve Drain Valve (shown in closed position) Heating Element Stainless Steel Tank Note: For illustrative purposes only. Some components may be omitted or altered for clarity. Do not use for wiring, repair or other purposes not related to component identification.
installer mr .steam Steam@Home ________________________________________________________________________ ® ® Installation, Operation & Maintenance Manual Dimensional Information STEAMSTART® On/Off Switch Box Contents: • SteamStart Control • Control Cable Installing the STEAMStart® Control The SteamStart has a 30 foot cable with a Plug & Play connector at both ends. (Diagram 1). A 60 foot control cable is available (103978-60).
® ® SteamStart® Controls Safety and Operating Information Use the SteamStart® control to turn the steam generator on. The SteamStart control will only light up when the steam generator is on. The steam generator will automatically shut off at 20 minutes, to turn the steam generator off manually prior to the automatic shut off, press the button on the SteamStart control. The SteamStart control may blink if the steam generator is not functioning properly (see page 9).
______________________________________________________________________________________________________________________________________________ Products, information and specifications are subject to change without notice. Please call Sales & Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information. ______________________________________________________________________________________________________________________________________________ mr.