Operating Guide

mr
.
steam
®
towelwarmers Electric Models
_________________________________________________________________
Installation and Operating Instructions
10
ELECTRICAL SPECIFICATIONS
Field Wired Models:
W500, W510, W542, W552, W554, W562, W572, W634,
W
842
Plug-in Models: W556, W856
ELECTRICAL CONNECTIONS
TO PREVENT SHOCK HAZARD, BE CERTAIN THAT ELECTRICITY IS TURNED OFF AT THE MAIN PANEL
BEFORE ANY WIRING IS DONE.
All wiring must conform to National Electrical and Local Codes.
GENERAL:
The Towel Warmer requires 120VAC, 60 Hz power supply.
Specific amperage needed is listed in the Towel Warmer Specifications Chart on page 2 of
PUR
103852.
A. Electrical connections should be made as prescribed by the National Electric and Local Codes. The unit should be
field wired using 14 AWG min 90°C-rated copper wire. All models are to be protected by a separate 15 amp circuit breaker or equal.
B. Make connections between Towel Warmer and house wiring using approved connections to comply with National Electrical Local Codes.
LINE (black), NEUTRAL (white), and GROUND.
C. Install the Towel Warmer according to the specific instructions for each model
.
TO PREVENT SHOCK HAZARD, NO BARE WIRE OR WIRE STRANDS SHOULD
BE VISIBLE AFTER MAKING CONNECTIONS.
Electric Towel Warmer
Thermal Fuse
Thermostat
Heating Element Wiring Box
Field Wiring
L
N
GRND
L
N
GRND
Field Installed Wall Switch or
Mr. Steam Digital Programmable Timer
PN: 103588DIG
Indicator Light
X
X
X
!
WARNING
!