Please read this manual carefully before installation and keep it for future reference. User Manual Advantage Series Please keep this manual where the operator can easily find it. Inside you will find helpful hints on how to use and maintain you unit.
READ BEFORE OPERATION When using this air conditioner in the European Union, the following informations must be followed: DISPOSAL: possibilities: 1 For more details visit www.MrCool.
CONTENTS SAFETY PRECAUTIONS 3 4 NAMES OF PARTS Indoor unit ................................................................................................................................. 5 Outdoor unit .............................................................................................................................. 5 Display window ..........................................................................................................................
SAFETY PRECAUTIONS WARNING CAUTION Strictly prohibited. Be sure to follow the instructions. WARNING shock. before you start to clean it. this unit. repair or maintenance of this unit. cable. room such as a bathroom or laundry room. use of the appliance by a person responsible for their safety. they do not play with the air conditioner. 3 For more details visit www.MrCool.
SAFETY PRECAUTIONS CAUTION may cause an electric shock. the intended use. emitted air. accordance with the local codes. 4 For more details visit www.MrCool.
NAMES OF PARTS 1 2 Air inlet 3 Names of parts 7 Indoor unit: 1. Front panel 2. Air inlet 4. Air outlet 4 5 Air outlet 6 7. Display window 8 Air inlet (side) Outdoor unit: NOTE: All the pictures in this manual are for explanation purposes only. The actual shape of the indoor unit Air inlet (rear) and display window. The actual shape shall prevail. 9 Air outlet Display window 10 conditioner is operational. Display window ON set.
OPERATING INSTRUCTIONS Operating temperature Mode Temperature Roomtemperature Outdoor temperature Cooling operation 62°F~90°F (17°C~32°C) 32°F~122°F (0°C~50°C) 5°F~122°F / -15°C~50°C (For the models with low ambient cooling system) Heating operation Drying operation 32°F~86°F (0°C~30°C) 50°F~90°F (10°C~32°C) 5°F~86°F (-15°C~30°C) 32°F~122°F (0°C~50°C) NOTE: 1. Optimum performance will be achieved within these operating temperatures.
OPERATING INSTRUCTIONS temperatures. control. Perform this function while the unit is in operation. Range and down automatically. Please refer to the IMPORTANT: the blower and suction side.The high-speed fan inside may cause injury. rod CAUTION condensation may occur on the surface of the performance may be reduced due to too air conditioner. Range 7 For more details visit www.MrCool.
OPERATING INSTRUCTIONS How the air conditioner works SLEEP operation dependent) AUTO operation 7 hours timer temperature and the room temperature. Set Temperature 1 hour automatically to the temperature point you set. 1 hour your desired temperature. Cooling SLEEP operation SLEEP operation 7 hours timer Set Temperature DRYING operation 1 hour 1 hour Heating HEATING operation performance is reduced as outdoor air temperature Optimal operation torwards people. closed. needed.
OPERATING INSTRUCTIONS Special functions Refrigerant Leakage Detection (optional) EC dependent). Louver Angle Memory Function (optional) Self Clean Function (optional) automatically. Note: for about 30 minutes. Clean Air Function (optional) Anti-Mildew Function (optional) Anto-Restart Function (optional) 9 For more details visit www.MrCool.
OPERATING INSTRUCTIONS WIFI Control Function (optional) Air Filter Reminding Function (optional) CL CL CL nF nF nF Mute Operation (optional) Press the LED button on the remote control to turn off the screen display and air conditioner buzzer of the indoor unit, creating a comfortable and quiet environement. 10 For more details visit www.MrCool.
CARE AND MAINTENANCE Before mainatenance NOTE: Power supply must be disconnectd before attampting to clean or service! CAUTION the unit. to crack or deform. Cleaning the unit FilterTab please use the suspension bars to prop up the panel. lter 11 For more details visit www.MrCool.
CARE AND MAINTENANCE left. Plasma (optional) and the panel is completely closed. Open the panel and take down the Preparation for extended non-operation of the Plasma and lifting it upwards according to the arrows. 2. Operate the fan for about half a day to dry the inside of the unit. 3. Stop the air conditioner and disconnect power. Dust collector ) Releasingthe buckles as indicated with arrows and open the cover of the with vacuum. Pre-season inspection 2 CAUTION possible electric shock.
TROUBLESHOOTING Symptom Cause To prevent blowout of the fuse, the compressor will not operate while Operation is delayed theprotection circuit is working for about 3 minutes after sudden OFF--ON after restart operation of the power supply.
TROUBLESHOOTING Diagnostic Symptom -- Is there a power failure? Unit will not operate -- Has a switch been turned off, a circuit breaker tripped or a fuse blown? -- Is the timer operating? -- Are the batteries used in the remote controller exhausted? -- Are the batteries used in the remote controller loaded properly? -- Are the air filters dirty? -- Is air flow unrestricted in & out of indoor & outdoor units? -- Are the temperature and mode settings correct? Poor cooling or heating performance -- Are
TROUBLESHOOTING Indoor Unit Error Display Operation lamp Timer lamp Display 1 time X E0 Indoor unit EEPROM parameter error 2 times X E1 Indoor / outdoor units communication error 3 times X E2 Zero-crossing signal detection error 4 times X E3 Indoor fan speed has been out of control 5 times X E4 Indoor room temperature sensor T1 open circuit or short circuit 6 times X E5 Evaporator coil temperature sensor T2 open circuit or short circuit 7 times X EC Refrigerant leakage detectio
Advantage Series