Please read this manual carefully before installation and keep it for future reference. User Manual Advantage Series Please keep this manual where the operator can easily find it. Inside you will find helpful hints on how to use and maintain your unit properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your unit. You’ll find answers to many common problems within this manual. For more information visit www.mrcool.com.
NOTICE When using this air conditioner in the European countries, please read the following information: •This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to property. •Meanings of the symbols used in this manual are as shown below Strictly prohibited.
SAFETY PRECAUTIONS CAUTION •Never actuate any switches with a wet hand. It may •If the air conditioner is to be used in conjunction cause an electric shock. with other heaters, the air should be refreshed •Never use the device for any other purpose than the periodically, otherwise there is a risk of lack of intended use. oxygen. •Never place food, precision instruments, plants, •Always pull out the power plug if the unit is not animals, paint, etc. on the unit.
NAMES OF PARTS Indoor unit 1 2 1. Front panel 2. Air inlet 3. Air filter 4. Air outlet 5. Horizontal air flow grill 6. Vertical air flow louver(inside) 7. Display panel 4 5 3 7 6 8 Outdoor unit 8. Connecting pipe 9. Connecting cable 10. Stop valve Air inlet(rear) Air inlet (s ide) NOTE: All the pictures in this manual are for explanation purposes only. The actual shape of the indoor unit you purchased may be slight different on front panel and display window.The actual shape shall prevail.
OPERATING INSTRUCTIONS Special functions Refrigerant Leakage Detection With this new technology, the dipsplay area will appear EC and the indication lamps continue flashing when the outdoor unit detects refrigerant leakage. Louver Angle Memory Function (optional) Within the scope of safety angle, it will memorize the open angle of horizontal louver. If it exceeds, it will memorize the boundry of safety angle.
OPERATING INSTRUCTIONS Operating temperature Temperature Mode Room temperature Outdoor temperature Cooling operation 62°F~90°F (17°C~32°C) 32°F~122°F (0°C~50°C) (5°F~122°F / -15°C~50°C For the models with low temperature cooling system) Heating operation Drying operation 32°F~86°F (0°C~30°C) 50°F~90°F (10°C~32°C) 5°F~86°F (-15°C~30°C) 32°F~122°F (0°C~50°C) NOTE: 1. Optimum performance will be achieved within these operating temperatures.
OPERATING INSTRUCTIONS Airflow direction control Adjust the air flow direction properly, otherwise it might cause discomfort or cause uneven room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually. To set the vertical air flow (Up - Down) direction Perform this function while the unit is in operation. Use the remote controller to adjust the air flow direction.
OPERATING INSTRUCTIONS How the air conditioner works AUTO operation •When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling/heating models only), or fan only operation depending on set temperature and the room temperature. •The air conditioner will control room temperature automatically to the temperature point you set. •If you feel uncomfortable in the AUTO mode, you can set your desired temperature.
CARE & MAINTENANCE Before mainatenance •Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. NOTE: Power supply must be disconnectd before cleaning the indoor unit. CAUTION •A cloth dampened with cold water may be used on the indoor unit if it is very dirty. Then wipe it with a dry cloth. •Do not use a chemically treated cloth or duster to clean the unit. •Do not use benzine, thinner, polishing powder, or similar solvents for cleaning.
CARE & MAINTENANCE 5. Install the air freshening filter back into position. 6. Insert the upper portion of air filter back into the unit, taking care that the left and right edges line up correctly and place filter into position. Replacement of air filter and air freshening filter 1. Remove the air filter. 2. Remove the air freshening filter. 3. Install a new air freshening filter. 4. Reinstall the air filter and securely close the front panel.
TROUBLESHOOTING Normal function of the air conditioner The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection •The compressor can't restart for 3-4 minutes after it stops. Anti-cold air (Cooling and heating models only) •The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached. A) When heating has just started. B) Defrosting.
TROUBLESHOOTING 7. The air conditioner runs function after turning off the unit. •When turning off the unit under COOL(AUTO COOL, FORCED COOL) and DRY mode, the air conditioner will run Anti-mildew function for 7-10 minutes, if it turns off on HEAT mode, the unit will continue operating for about 30 seconds at LOW fan speed, then stop the operation and turn off the unit automatically. 8.
TROUBLESHOOTING Troubleshooting guide OPERA TION(R UN) ind icator o r other indicators con tinue flashing . If one o f the fo llowing code a ppears on the Trouble display area : E0,E1, E2,E3. ....or P 0,P1,P 2, P3...., F1,F2, F3....... The unit may stop operation or continue to run in a safety condition(depending on models). Waiting for about 10 minutes, the fault may be recovered automatically, if not, disconnect the power and then connect it in again.
Advantage Series The design and specifications are subject to change without prior notice. Consult with the sales agency or manufacturer for details. For more information visit www.mrcool.com.