Installation Manual
Page 17 mrcool.com
Indoor Unit Installation
SIGNAL CABLE PROTECTION
The signal cable must be protected by conduit
before being pushed through the wall hole.
2.  Using vinyl tape, attach the drain hose to the 
 underside of the refrigerant pipes.
3. Using insulation tape, wrap the refrigerant pipes
 and drain hose tightly together. Double-check
 that all items are bundled in accordance with 
 Fig. 4.8.
DO NOT WRAP ENDS OF PIPING
When wrapping the bundle, keep the ends of 
the piping unwrapped. You need to access them 
to test for leaks at the end of the installation 
process (refer to Electrical Checks and Leak 
Checks section of this manual).
Step 8: Mount indoor unit
Step 7: Wrap piping 
Before passing the piping and drain hose through 
the wall hole, you must bundle them together to 
protect them, insulate them, and save space.
1. Bundle the drain hose and refrigerant pipes 
 according to Fig. 4.8. 
DRAIN HOSE MUST BE ON BOTTOM
Make sure that the drain hose is at the bottom 
of the bundle. Putting the drain hose at the top of 
the bundle can cause the drain pan to overflow, 
which may lead to fire or water damage.
Indoor Unit
Space behind unit
Refrigerant piping
Drain hose
Insulation tape
Fig. 4.8
If you installed new connective piping to the 
outdoor unit, do the following:
If you have already passed the refrigerant piping 
through the hole in the wall, proceed to Step 4.
Otherwise, double-check that the ends of the 
refrigerant pipes are sealed to prevent dirt or 
foreign material from entering the pipes.
Slowly pass the wrapped bundle of refrigerant 
pipes and drain hose through the hole in the wall.
Hook the top of the indoor unit on the upper 
hook of the mounting plate.
Check that unit is hooked firmly on mounting 
plate by applying slight pressure to the left and 
right-hand sides of the unit. The unit should not 
jiggle or shift.
Using even pressure, push down on the bottom 
half of the unit. Keep pushing down until the unit 
snaps onto the hooks along the bottom of the 
mounting plate.
Again, check that the unit is firmly mounted by 
applying slight pressure to the left and the 
right-hand sides of the unit.
1. 
2.  
3.  
4. 
5. 
6.  
7. 