Refrigerant Piping Connection
Before Test Run
Test Run Instructions
List of Checks to Perform PASS/FAIL
Outdoor (2): 
Indoor (2):
No electrical leakage
Unit is properly grounded
All electrical terminals 
properly covered
Indoor and outdoor units 
are solidly installed
All pipe connection points 
do not leak
Water drains properly 
from drain hose
All piping is properly 
insulated
Unit performs COOL 
function properly
Unit performs HEAT 
function properly
Indoor unit louvers rotate 
properly
Indoor unit responds to 
remote control
You should perform the Test Run for at least 30 
minutes.
1. Connect power to the unit.
2. Press the ON/OFF button on the remote
 controller to turn it on.
3. Press the MODE button to scroll through the
 following functions, one at a time:
  • COOL – Select lowest possible temperature
 • HEAT – Select highest possible temperature
4. Let each function run for 5 minutes, and perform
 each of the checks listed in the table to the right:
Only perform test run after you have completed 
the following steps:
• Electrical Safety Checks – Confirm that the 
electrical system is safe and operating properly
• Gas Leak Checks – Check all flare nut 
connections and confirm that the system is not 
leaking
• Confirm that gas and liquid (high and low 
pressure) valves are fully open