How to Guide

STEP 1 - inside STEP 3 - inside
STEP 2 - inside
1. Drill screw holes at the indicated points into
studs.
2. Remove the bracket from the rear of the interior
air handler.
3. Screw the metal bracket to the wall according to
the template.
4. Use a level to
ensure the
mounting plate is
flush and level.
1. Locate the wall template.
2. Place the template on the wall at the installation
location.
3. Use the template
to mark the drill
points and wall hole
site.
4. Remove the template.
Wall
Indoor Outdoor
0.2 - 0.3in
(5 - 7 mm)
1. Drill a 3.5 inch diameter hole through the wall, at
a slightly downward angle, to accommodate the
line set, condensate drain line and communication
cable to the exterior condenser.
2. Use the vinyl tape to wrap the line set,
condensate drain line and communication cable
into a bundle. The drain MUST be on the bottom.
3. Push the bundle through the wall hole.
condensate