How to Guide

1 2
4. Snap the air handler onto the wall bracket.
STEP 3 - continued
STEP 4 - outside
STEP 4 - continued
1. Place outside condenser unit firmly on the
ground or attach it to a secure metal wall bracket
or pad. Drain pipe is not required and can be
installed as necessary only if elevated.
2. Remove the plastic seals from the indoor
handler refrigerant lines.
3. Carefully unroll the amount of Quick Connec
line set needed to connect the indoor handler
fittings and the outside condenser. Leave the coiled
portion stored near the condenser.
4. Align the Quick Connect® refrigerant lines to the
matching indoor handler fittings. Tighten the first
few threads by hand.
5. Using open ended wrenches (i.e. crescent or
adjustable): hold the points marked “1” and turn
the nuts only at the points marked “2” (Select the
appropriate wrench according to the dimensions of
the connector).
6. Ensure that the screw connectors do not skew
while working quickly to tighten them.
Ground Installed:
12 in (30 cm)
Bracket Installed:
6 in (15 cm)
clearance between
back and wall
79in (200cm)
in front
12in (30cm)
on left
24in (60cm)
above
24in (60cm)
on right